Electrical connection
T20WN
A0726-14.0
11
A
B
C
D
E
F
G
J
H
L
M
K
Pin
Pin assignment
Wire
colour
Bridge
Switch
(NO)
Release cali
bration signal
(without
VK20A)
A
No function
BK
B
Measurement signal speed/
angle of rotation 5 V
RD
C
Measurement signal torque
"
10 V
BN
D
Measurement signal torque
0 V
WH
E
Ground (speed/
angle of rotation)
YE
F
Supply v12 V
VT
G
Measurement signal speed/
angle of rotation 5 V, 90
°
phase shifted
GN
H
No function
PK
J
No function
GY
K
Control signal trigger
GY/PK
L
No function
BU/RD
M
Cable shield
BU
4.3
Cable extension
Extension cables must be the shielded, low‐capacitance
type. We recommend the use of HBM cables that comply
with these requirements.
When using cable extensions, ensure that the connection
is perfect, with the lowest possible contact resistance and
good insulation. For this reason all connections should be
soldered, or at the very least should use firmly fixed
terminals or screwed connectors.
Содержание T20WN
Страница 1: ...Mounting instructions Montageanleitung Notice de montage English Deutsch Francais T20WN...
Страница 3: ...Mounting instructions Montageanleitung Notice de montage English Deutsch Francais T20WN...
Страница 30: ...Accessories 28 A0726 14 0 T20WN...
Страница 31: ...Mounting instructions Montageanleitung Notice de montage English Deutsch Francais T20WN...
Страница 58: ...Zubeh r 28 A0726 14 0 T20WN...
Страница 59: ...Mounting instructions Montageanleitung Notice de montage English Deutsch Francais T20WN...