46
Scout 55
HBM
A0236-5.9 en
Functions
Level 0V
Level 24V
NO FUNCT.
no function (factory setting)
AUTOCAL
Autocalibration ON
Autocalibration OFF
TARE
For the transition 0V
−
24 V, the tare value is adopted
PVS1 INST
Peak value operating mode for
PV1
Instantaneous value operating
mode for PV1
PVS1/HOLD
Store contents PV1 and PV3 are
updated
Store contents PV1 and PV3 are
frozen
PVS2 INST
Peak value operating mode for
PV2
Instantaneous value operating
mode for PV2
PVS2/HOLD
Store contents PV2 are
updated
Store contents PV2 are
frozen
ZEROING
For the transition 0V
−
24 V, the current instantaneous input signal is
adopted as the zero value
A printout is triggered over the
interface
GROSS/NET
Gross at analogue output
Net at analogue output
PARACODE 1
External selection of parameter sets and binary coded
inputs
PARACODE 2
(see following table)
PARACODE 3
BUTTON.LOCK
ENABLED
LOCKED
PARAM. SET
PARACODE
3
2
1
1
0
0
0
2
0
0
1
3
0
1
0
4
0
1
1
5
1
0
0
6
1
0
1
7
1
1
0
8
1
1
1
REMOTE
Device control through remotes can be locked or enabled.
ON
no display
Operating using keyboard and remotes
OFF
LOCAL
Keyboard operation only