Specifications
CAN interface
Number of CAN interfaces
2
Protocol
CAN 2.0B
Baud rate
Baud
10k
20k
50k
125k
250k
500k
1M
Line length
m
1000
1000
1000
500
250
100
25
Hardware bus link individually selecta-
ble for each CAN interface
Standard High Speed ISO 11898−24 V
Fault Tolerant Low Speed
Connection technique
2x 9−pin DSUB, individual potential separation
of supply and ground
Measurement recording
Number of signals at 1 Mbaud, 11 bit
Format INT16;
Signals
1 ... 8
Hz
Output rate
2400
9 ... 16
1200
17 ... 24
800
25 ... 32
600
33 ... 48
400
49 ... 64
300
65 ... 96
200
97 ... 128
100
Format Float, INT32;
Signals
1 ... 4
Hz
2400
5 ... 8
1200
9 ... 12
800
13 ... 16
600
17 ... 24
400
25 ... 32
300
33 ... 48
200
49 ... 96
100
97 ... 120
80
121 ... 128
50
Database with parameter information
via the CAN signals
2 (one database per CAN interface)
Size of databases
Byte
2x 100 k
Database storage
non−volatile in ML71B flash memory