Mechanical installation
10
A3916-2.0
HBM: public
FIT®5A
application can be mounted on top. The screws and tightening torques to be
used are given in the table below:
Mounting
Thread
Min. property class
Tightening torque
On mounting plate
M6
10.9
10N
⋅
m
For load application
M6
10.9
10N
⋅
m
1)
Recommended value for the specified property class. Please comply with the screw
manufacturer's instructions with regard to screw dimensions.
Direction of loading
center of platform
max. 30.5
Adapter
(flatness
v
0.02mm on
the mounting surface)
Alternative load
application
Platform
Mounting base
(flatness
v
0.02mm on
the mounting surface)
max. 70.5
∅
20
Device socket 2
(extended version E only)
Device socket 1
Fig. 4.1
Load application and installation
Important
The surface flatness of the components mounted on the load cell must be bet
ter than 0.02 mm.