![HBM DMP41 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/hbm/dmp41/dmp41_interface-description_2111867056.webp)
Command set of the HBM interpreter
Amplifier functions
56
A03474_04_E00_00
HBM: public
DMP41
5.4
Amplifier functions
5.4.1
Output format, measured value output
Change Output Format
Change measured value output format
Syntax:
COF p1(x)
Parameter:
p1
Measured value output format
0
Measured value, channel, status (ASCII format)
1
Measured value (ASCII format)
2
Binary measured value output 4 byte (MSB XX XX LSB)
3
Binary measured value output 4 byte (LSB XX XX MSB)
4
Binary measured value output 2 byte (MSB LSB)
5
Binary measured value output 2 byte (LSB MSB)
4 byte output:
1
2
3
4
MSB
LSB
3 byte measured value
1 byte status
7680000 = Measuring range full scale (unit)
The output value multiplied by 1/2560 is equivalent to the measured value in
degrees for thermocouples and the units 5C,5F, K.
Sta
tus
Significanc
e
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
GUI
message
0
OK
Measureme
nt without
warnings or
error
0
0
0
0
LV
4
LV
3
LV
2
LV
1
1
Warn
ing
Filter setting
0
x
x
1
LV
4
LV
3
LV
2
LV
1
Change color
of filter text
2
Overflow
0
x
1
x
LV
4
LV
3
LV
2
LV
1
Display
warning
symbol
COF
Содержание DMP41
Страница 1: ...Interface description and command set English DMP41 Digital precicion measuring device...
Страница 10: ...Interface comparison 10 A03474_04_E00_00 HBM public DMP41...
Страница 14: ...Communication with the DMP Ethernet interface 14 A03474_04_E00_00 HBM public DMP41...
Страница 18: ...Communication with the DMP RS 232 interface 18 A03474_04_E00_00 HBM public DMP41...
Страница 22: ...Program creation Communication via the Ethernet interface Test program 22 A03474_04_E00_00 HBM public DMP41...
Страница 86: ...Functional command overview 86 A03474_04_E00_00 HBM public DMP41...
Страница 90: ...Index 90 A03474_04_E00_00 HBM public DMP41...
Страница 91: ...Index DMP41 A03474_04_E00_00 HBM public 91...