background image

Notes on the Installation, Initial Start-up, Operation

Radio Receiver FSE 514

BE-514_I-V1-3-FCC.doc.doc [ Word 2000 ] MB

Page 13 / 18

HBC-radiomatic GmbH • D-74564 Crailsheim • GERMANY

Information and specifications subject to change without notice.

30-04-2003

Radio System

3.2

Automatic HOLD Function Settings (Eltako)

The automatic HOLD function of relay K12 can be activated or deactivated
(latched/unlatched) with switches S2 and S3 on the relay board.
For example, the relay can be used together with the "Light" function (remote control
circuit).

!

  The automatic HOLD function is activated (latched) when switches 

S2 und S3

 are

set to position 

II

.

!

  The automatic HOLD function is deactivated (unlatched) when switches 

S2 und S3

are set to position 

I

.

Содержание FSE 514

Страница 1: ...FSE 514 BE 514_I V1 3 FCC doc doc Word 2000 MB Page 1 18 HBC radiomatic GmbH D 74564 Crailsheim GERMANY Information and specifications subject to change without notice 30 04 2003 Radio System HBC Radio Control R Ra ad di io o R Re ec ce ei iv ve er r F FS SE E 5 51 14 4 ...

Страница 2: ...tic GmbH Haller Strasse 49 53 74564 Crailsheim Germany Tel 49 0 79 51 3 93 0 Fax 49 0 79 51 3 93 50 E mail info radiomatic com http www hbc radiomatic com HBC radiomatic GmbH is not liable for any misprints or errors All rights reserved radiomatic is a registered German trademark 2003 04 HBC radiomatic GmbH D 74564 Crailsheim No part of any software or of the present document may be reproduced in ...

Страница 3: ... Safety Instructions 6 2 1 Pictographs 6 2 2 General Safety Instructions 7 2 3 Safety Instructions for Installation and Operation 8 2 4 FCC Rules 9 3 Installation and Mains Connection 10 Proper Installation of the FSE 514 Radio Receiver 11 3 1 Radio Status Panel 12 3 2 Automatic HOLD Function Settings Eltako 13 4 Fault Correction 14 5 Maintenance 15 5 1 In The Event of a Fault 15 6 Technical Data ...

Страница 4: ...cated to each HBC radio transmitter and its respective receiver It is not possible to activate crane or machine functions using a radio control system allocated to another crane or machine The radio receiver has general telecommunications approvals It is not necessary to have or to apply for a license to operate the receiver and the respective transmitter The radio receiver broadcasts in either a ...

Страница 5: ...ing hardware 1 receiver operating instructions Installation Commissioning and Operating Instructions To ensure that the radio control system arrives intact HBC radiomatic GmbH packs its systems in reusable packaging material We recommend storing all packaging materials in a safe place in case of later use 1 1 1 Transport Insurance When unpacking your radio control system check for possible transpo...

Страница 6: ...the device from the mains supply supply voltage operating voltage or input terminal voltage indicates safety relevant passages You will find this pictograph as an indicator for occupational safety measures The neglecting of such measures poses a serious hazard Always observe the instructions and be particularly attentive and careful Avoid any situations that could at any time be a danger to person...

Страница 7: ...he transmitter on ensure that no one is or can be endangered by the initiated operation With the first signs of any malfunction related to the operative safety and reliability of the device the operator must immediately shut down or not activate the radio receiver For the purpose of the present manual shut down implies switching OFF the transmitter storing the transmitter in a safe place and ensur...

Страница 8: ...ctricity Contact to these components as well as to mains voltage is hazardous Only connect the radio receiver to machines or cranes that are designed for radio controls Prior to welding the crane or machine disconnect the connection cable to the crane or machine Switch off the radio control system as well as the crane or machine In case of an emergency or any disturbances within the working range ...

Страница 9: ...etermined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV te...

Страница 10: ...ricity Contact to these components as well as to mains voltage is hazardous The radio receiver FSE 514 is to be mounted using the rubber vibration dampers included The rubber vibration dampers are to be screwed to the mounting loops on the upper and lower edge of the receiver ℑ The radio receiver is connected to the crane or machine electronics through the heavy threaded compression gland ℜ The ra...

Страница 11: ...adio Receiver FSE 514 BE 514_I V1 3 FCC doc doc Word 2000 MB Page 11 18 HBC radiomatic GmbH D 74564 Crailsheim GERMANY Information and specifications subject to change without notice 30 04 2003 Radio System Proper Installation of the FSE 514 Radio Receiver ...

Страница 12: ...ctronic system as a result of radio interference it is recommended for you to also switch OFF your transmitter and monitor if the HF RF H F HF LED is extinguished nevertheless Exception With radio systems that are equipped with a frequency selector function optional the HF RF H F HF LED will either extinguish or flash This indicates that the receiver is searching scanning the stored frequencies av...

Страница 13: ...3 2 Automatic HOLD Function Settings Eltako The automatic HOLD function of relay K12 can be activated or deactivated latched unlatched with switches S2 and S3 on the relay board For example the relay can be used together with the Light function remote control circuit The automatic HOLD function is activated latched when switches S2 und S3 are set to position II The automatic HOLD function is deact...

Страница 14: ...however the crane does not carry out the control commands The receiver is not connected to the mains supply There is no radio contact between transmitter and receiver The command crane ON has not been activated Check the mains cable leading to the receiver Check the fuses in the receiver housing Check receiver functions using the LEDs in the indicator lamp panel on the receiver Some command statem...

Страница 15: ...ing Never operate a crane or machine with a faulty or defective radio control system Never try to repair the radio receiver electronics Opening the transmitter housing terminates the manufacturer guarantee Send any defective or faulty equipment to your local distributor or to the manufacturer They are experts and have the necessary know how and OEM spare parts Always send transmitter and receiver ...

Страница 16: ...ombinations Command output relays 250 V 2 A Output wiring none standard Operating voltage range 100 V 240 V 50 60 Hz Connection heavy thread compression gland Operating temperature range 20 C to 55 C Housing material plastic compound PA6 GF30 Housing color orange Dimensions 202 x 269 x 60 mm 8 0 x 10 6 x 2 4 Weight approx 1 3 kg 2 8 lb Protection class IP 55 RF Specific Technical Data TC690 Freque...

Страница 17: ... Radio Receiver FSE 514 BE 514_I V1 3 FCC doc doc Word 2000 MB Page 17 18 HBC radiomatic GmbH D 74564 Crailsheim GERMANY Information and specifications subject to change without notice 30 04 2003 Radio System 6 1 Dimensions of the FSE 514 Radio Receiver ...

Страница 18: ...peration Radio Receiver FSE 514 Page 18 18 BE 514_I V1 3 FCC doc doc Word 2000 MB HBC radiomatic GmbH D 74564 Crailsheim GERMANY 30 04 2003 Information and specifications subject to change without notice Radio System 7 Certificates and Approvals ...

Отзывы: