background image

Instruction manual

www.hazebase.de

Содержание THE FAB

Страница 1: ...Instruction manual www hazebase de...

Страница 2: ...Hazer THE FAB incl Flightcase 19 2U 1 liter empty canister Fuel tank cap with quick coupling Power cord with TrueOne plug 1 liter base V vegan special fluid Instruction manual Please check the comple...

Страница 3: ...Ethernet 10 6 5 Operation via cable remote control option 11 6 6 Operation via radio remote control option 12 7 Settings 14 7 1 Ethernet interface settings 15 7 1 1 Setting the IP addresses control 1...

Страница 4: ...and adjustable fans allow it to be used in areas where ambient noise is a nuisance THE FAB also offers countless possibilities for control In addition to the direct operation on the device via touch s...

Страница 5: ...kage of hot fluid droplets is possible Care should therefore be taken to ensure that these cannot become a hazard to people Keep a safety distance of 3m to the fog outlet nozzle Do not ingest the fog...

Страница 6: ...ation of the parts Front view Rear view 5 Fluid Input 1 Fluid canister Air blades Fog nozzle Fan Inlet TFT display with touch screen Power supply 10 100MBit Ethernet Art Net and sACN DMX RDM radio and...

Страница 7: ...from the quick coupling by pressing the locking button Hold the suction hose in the right edge of the fluid compartment Remove the canister from the fluid compartment Unscrew the tank cap from the emp...

Страница 8: ...Please ensure that no objects are placed either at the air inlet or outlet so that free circulation is possible After plugging in the power plug the main menu appears The machine does not yet heat up...

Страница 9: ...via Ethernet the right symbol shows whether THE FAB is connected to the mains supply or is currently being supplied via the internal battery In the case of battery operation the battery charge status...

Страница 10: ...tes between down and straight straight the discharge direction is straight straight up the discharge direction always alternates between up and straight up the discharge direction is upwards To enter...

Страница 11: ...the pump value The second channel controls the fan speed and the third channel the air baffles if 3 channel mode is active Via RDM THE FAB is configurable DMX address as well as readable errors speeds...

Страница 12: ...be selected The value area shows whether the remote input is active or not By tapping in the value area the remote input can be switched on and off If the remote input is activated and a wired remote...

Страница 13: ...As soon as the remote input is activated and a radio receiver is plugged in THE FAB recognizes the radio receiver If the handheld transmitter and the receiver have not yet been taught to each other t...

Страница 14: ...which the machine should react A selected key then appears with a blue outline When the corresponding key on the handheld transmitter is pressed the field appears in green You can also select several...

Страница 15: ...e menu button at the bottom center of the main screen Here the settings of the machine can be made 14 IP address protocol and universes settings Screen settings brightness screen saver orientation Mac...

Страница 16: ...at the bottom left shows the currently selected protocol This can be changed by tapping the button At the top right the current IP address can be changed In the middle right the subnet mask can be ch...

Страница 17: ...ct the desired setting in the right pane 7 1 2 Setting the IP address static The static IP address can be set in this menu Select the desired quardruple in the values area and type it in using the num...

Страница 18: ...and the sACN protocol are available On the left side the desired protocol is selected On the right side the corresponding universe is then set This is done by tapping the value in the value range and...

Страница 19: ...nd channel for the fan speed and the third for the position of the air baffles In Reduced Mode the third channel is not coupled to the DMX data and must be set on the device before 7 3 Screen settings...

Страница 20: ...u may deactivate the status LEDs above the Ethernet sockets The setting is done in the center right 7 4 Consumption display THE FAB has a level indicator on the main screen Please note that this indic...

Страница 21: ...is touch the display for 3 sec This starts the battery operation Now make all settings After 10 sec the display will be switched off again THE FAB also provides a web server Type the IP address of THE...

Страница 22: ...canister frequently you should rinse it thoroughly before each filling with fresh fluid This will prevent contamination If necessary clean the surface of the device with a suitable solvent free cleani...

Страница 23: ...costs Refill fluid Check hose and coupling engage again if necessary If the pump has run dry hold the FAB with the front side down and let it mist for a few seconds The fluid pump will then fill comp...

Страница 24: ...FAB THE FAB shows the error message communication with vaporizer failed in the display Communication from the main processor to the evaporator does not work The machine shuts down for safety reasons...

Страница 25: ...tor adjustable Haze output Adjustable 1 100 in 1 steps Fan speed Adjustable 1 100 in 1 steps Supported protocols DMX512 RDM JT Remote sACN Art NetTM Control DMX RDM cable remote control radio remote c...

Страница 26: ...rventions are carried out by persons who are not authorized by us to do so or if our devices are equipped with supplementary or accessory parts that are not matched to our devices Furthermore the warr...

Страница 27: ...e is remunerated or c take back the device for a refund of the purchase price but not more than the market price 7 Further or other claims in particular those for compensation for damage occurring out...

Страница 28: ...THE FAB 27...