Hayward Viio Turbo 5500TC Скачать руководство пользователя страница 9

8

Use Only Genuine Hayward Replacement Parts.

Connecting the 
Rigid Pressure Hose to Pool

7

7..

Lubricate the swivel on the 3 ft. Hose Wall End Assembly (Part T)
in soapy water then snap into one of the Pipe Assemblies.

8

8..

Lubricate the swivel on the Hose Cleaner End Assembly (Part S)
in soapy water then snap into a different Pipe Assembly.

9

9..

Open Bag #2 and lubricate both ends of the Hose Swivel
Assemblies (Part R) in soapy water. Connect the Pipe
Assemblies by snapping the Hose Swivel Assemblies into each
of the Pipe Assemblies.

C

Co

on

nn

ne

ec

cttiin

ng

g H

Ho

osse

e tto

o W

Wa

allll F

Fiittttiin

ng

g

1

1..

With the Booster Pump and Filtration system turned 

O

OF

FF

F

,

look down from the pool deck and hold the Wall Quick
Connect so the hose is to the left and the adjustment knob
is to the right. Insert the Wall Quick Connect into the
Universal Wall Fitting and turn it to the left (counter
clockwise) to lock. The hose should be on the bottom below
the adjustment knob.

2

2..

Pull the Wall Quick Connect outward to check that the Wall
Quick Connect is locked into the Universal Wall Fitting.

3

3..

To 

d

diis

sc

co

on

nn

ne

ec

ctt

the hose, first turn the Booster Pump and

Filtration pump 

O

OF

FF

F

then push the Wall Quick Connect

toward the wall, turn it to the right (clockwise) and pull the
Wall Quick Connect out of the Universal Wall Fitting.

D

Diissc

co

on

nn

ne

ec

cttiin

ng

g a

a H

Ho

osse

e P

Piip

pe

e

If it is necessary to shorten, lengthen or replace a component 
of the Rigid Pressure Hose, the Snap Fits can be undone with
two small screwdrivers.

W

Wa

allll Q

Qu

uiic

ck

k C

Co

on

nn

ne

ec

ctt

W

Wa

allll C

Co

on

nn

ne

ec

ctto

orr A

As

ss

se

em

mb

blly

y

H

Ho

os

se

e C

Clle

ea

an

ne

err E

En

nd

d A

As

ss

se

em

mb

blly

y

T

Q

N

H

Ho

os

se

e S

Sw

wiiv

ve

ell A

As

ss

se

em

mb

blly

y

R

N

R

Riig

giid

d P

Prre

es

ss

su

urre

e H

Ho

os

se

e A

As

ss

se

em

mb

blly

y

S

IItt iis

s e

es

ss

se

en

nttiia

all tth

ha

att tth

he

e H

Ho

os

se

e S

Sw

wiiv

ve

ell A

As

ss

se

em

mb

blliie

es

s a

arre

e

iin

ns

stta

alllle

ed

d c

co

orrrre

ec

cttlly

y tto

o e

en

ns

su

urre

e tta

an

ng

glle

e ffrre

ee

e o

op

pe

erra

attiio

on

n o

off tth

he

e

P

Ph

ha

an

ntto

om

m T

Tu

urrb

bo

o..

Содержание Viio Turbo 5500TC

Страница 1: ......

Страница 2: ...e the booster pump and is not covered by the Hayward warranty Always disconnect and remove the Viio cleaner and hoses from the pool before cleaning or backwashing the pool filter After cleaning or bac...

Страница 3: ...Operating the Viio Cleaner 9 Setting Pressure 9 Large Capacity Debris Bag 10 Correctly Operating Cleaner 11 Cleaner Adjustments 12 Changing Spin Out Frequency 12 Adjusting Spin Out Duration 12 Adjusti...

Страница 4: ...ed Warranty Registration Card within 14 days of purchase date or go to www haywardnet com warranty to fill out online Your warranty card is packed in the Owner s Guide and Accessory Pack Important Thi...

Страница 5: ...Adjustment Knob F Cam Cap G Rigid Pressure Hose H Hose Float I Hose Pipe Coupling J Hose Swivel See special installation instructions in this manual K Adjustable Wall Quick Connect L Sweep Hose M Wear...

Страница 6: ...d vacuum new surface debris before installing the Viio Pools with Excessive Sand Pools with excessive amounts of sand dense debris should be vacuumed manually before installing the Viio The Viper Bag...

Страница 7: ...5 5 When installing or re installing the Universal Wall Fitting use Teflon tape on its plastic threads Leave two starting threads on the end of the Universal Wall Fitting un taped 6 6 Screw the Univer...

Страница 8: ...he pool coping immediately above the Universal Wall Fitting 6 6 Unroll the Measuring Tape walk around the pool to the farthest point along the pool wall from the Universal Wall Fitting At the farthest...

Страница 9: ...to check that the Wall Quick Connect is locked into the Universal Wall Fitting 3 3 To d di is sc co on nn ne ec ct t the hose first turn the Booster Pump and Filtration pump O OF FF F then push the Wa...

Страница 10: ...ttached under water and not to be sprayed by the hole in the Setup Pressure Gauge or by the Sweep Hose N Ne ev ve er r point a jet or hose at people or pets Clip the Setup Pressure Gauge to the hose n...

Страница 11: ...2 Slide Float Closure off of bag figure 3A 3 Hold open edges apart and shake debris from bag figure 3B 4 Slide Float Closure onto bag Sand dense debris Always empty the Viio bag when sand or heavy de...

Страница 12: ...ay not pick up all debris on the first pass but your pool should be clean in 3 hours or less depending on pool size shape and the amount of debris in the pool O Ob bs se er rv ve e V Viiiio o s s o op...

Страница 13: ...s for more frequent Spin Outs If Viio rarely needs to back up and Spin Out near an obstacle then a cam with fewer prongs and less frequent Spin Outs will increase effective cleaning time Changing Spin...

Страница 14: ...if the sweep hose does not move side to side and just drags behind the cleaner check the Sweep Hose for holes Check for debris behind the adjustment screw or in the jet end of the Sweep Hose Sweep Ho...

Страница 15: ...3 Hold open edges apart and shake debris from bag 4 Slide Float Closure onto bag C Cl le ea an ni in ng g t th he e I In n L Li in ne e F Fi il lt te er rs s 1 1 The Hose In Line filter Part Q is loc...

Страница 16: ...set the timer so the Booster Pump will not turn on while the Viio cleaner is out of the pool Never operate the Booster Pump without the cleaner connected 2 Disconnect Wall Quick Connect from the Univ...

Страница 17: ...16 Use Only Genuine Hayward Replacement Parts Troubleshooting For Technical Assistance Call 1 908 355 7995...

Страница 18: ...1 AX6060Z1 Screw 1 4 Type b x 1 1 4 Set of 10 2 AX6060A Pump Volute 3 AX6060UNPAK Union Connector Kit incl 2 ea Union Hose Connector Union Pipe Connector Union Nut and Union O Ring 4 AX6060C Impeller...

Страница 19: ...eep Hose 16 AX6000HWA2V Pressure Hose and Top of In Line Filter Assembly 17 AX6000HFA Hose Swivel Assembly 18 AX6000HE Rigid Hose Pipe Section 2 Rigid Pipes and 1 Coupling 19 AX6000HWA1 Wall Quick Con...

Страница 20: ...ts 3 This Limited Warranty shall not apply to any injury loss damage defect or malfunction of the CLEANER or failure of the CLEANER to function resulting from any failure to operate or maintain the CL...

Страница 21: ...ll of Sale including date of purchase and serial number of the item claimed to be defective the name and address of the PURCHASER and a brief description of the problems defects encountered Call 908 3...

Страница 22: ...P N IS55OOTC Rev B 620 Division Street Elizabeth NJ 07207 Phone 908 351 5400...