Hayward Viio Turbo 5500TC Скачать руководство пользователя страница 16

15

Use Only Genuine Hayward Replacement Parts.

Replacing Parts

Sweep Hose

• Sweep Hose Wear Rollers will experience wear when

operating in a plastered or concrete pool.

• When the Wear Rollers wear-down to the outer groove (Wear

Line) replace the Wear Rollers (P/N AX5006A).

• Check the Sweep Hose for holes.

Some parts will wear with normal use. To insure the high
quality performance, insist on 

Genuine Hayward

replacement parts (using non-Hayward replacement
parts will Void the Viio Cleaner’s Warranty).

The following parts are user replaceable and subject to 
normal wear and tear.

1.

Sweep Hose:

If a hole forms in the Sweep Hose, it

should be replaced. Unscrew the mender nut from the
hose and pull the Sweep Hose off the Cleaner Connector.
Attach a new Sweep Hose to the Cleaner Connector.
(Replacement Part Number: AX6000RSHA)

2.

Debris Bag:

The Debris Bag should be replaced if it 

is torn.
(Replacement Part Number: AX5500BFA)

3.

Swivels:

If a swivel ceases to turn easily or leaks while

the cleaner is running, it should be replaced.
(3-Pack Replacement Part Number: AX5000SA) 

Storing the Viio Cleaner

1.

Turn the Booster Pump OFF 

and set the timer so the

Booster Pump will not turn on while the Viio cleaner is out
of the pool (

Never

operate the Booster Pump without the

cleaner connected).

2.

Disconnect Wall Quick Connect from the Universal Wall
Fitting. The Universal Wall Fitting may be left in place.

3.

The cleaner is constructed of the finest materials
available, however we recommend that when the Viio
cleaner is removed from the pool, it should be stored flat
on its wheels in a shaded area to protect the unit from
excessive exposure to ultraviolet solar rays.

4.

Store the Sweep and Pressure Hoses straight and flat,

not coiled

. If possible, store the hoses in the shade.

Winterizing the Cleaner

When closing your pool for the winter completely drain the
water from the Viio Cleaner (by slowly rotating it in all
directions) and Hoses. Store the Viio Cleaner indoors to

prevent freezing the inner mechanisms.

Periodic Freezing Conditions

If you are in an area subject to periodic freezing conditions, but
pool equipment is kept in operation, it is very important that
the filtration system and Viio cleaner be in operation during
times when hard freezing occurs (normally between 3AM and
7AM). Running the Viio cleaner at this time will insure against
damaging the Cleaner and may prevent freezing of pool water.

Wear Roller

Wear Line
(outer groove)

Содержание Viio Turbo 5500TC

Страница 1: ......

Страница 2: ...e the booster pump and is not covered by the Hayward warranty Always disconnect and remove the Viio cleaner and hoses from the pool before cleaning or backwashing the pool filter After cleaning or bac...

Страница 3: ...Operating the Viio Cleaner 9 Setting Pressure 9 Large Capacity Debris Bag 10 Correctly Operating Cleaner 11 Cleaner Adjustments 12 Changing Spin Out Frequency 12 Adjusting Spin Out Duration 12 Adjusti...

Страница 4: ...ed Warranty Registration Card within 14 days of purchase date or go to www haywardnet com warranty to fill out online Your warranty card is packed in the Owner s Guide and Accessory Pack Important Thi...

Страница 5: ...Adjustment Knob F Cam Cap G Rigid Pressure Hose H Hose Float I Hose Pipe Coupling J Hose Swivel See special installation instructions in this manual K Adjustable Wall Quick Connect L Sweep Hose M Wear...

Страница 6: ...d vacuum new surface debris before installing the Viio Pools with Excessive Sand Pools with excessive amounts of sand dense debris should be vacuumed manually before installing the Viio The Viper Bag...

Страница 7: ...5 5 When installing or re installing the Universal Wall Fitting use Teflon tape on its plastic threads Leave two starting threads on the end of the Universal Wall Fitting un taped 6 6 Screw the Univer...

Страница 8: ...he pool coping immediately above the Universal Wall Fitting 6 6 Unroll the Measuring Tape walk around the pool to the farthest point along the pool wall from the Universal Wall Fitting At the farthest...

Страница 9: ...to check that the Wall Quick Connect is locked into the Universal Wall Fitting 3 3 To d di is sc co on nn ne ec ct t the hose first turn the Booster Pump and Filtration pump O OF FF F then push the Wa...

Страница 10: ...ttached under water and not to be sprayed by the hole in the Setup Pressure Gauge or by the Sweep Hose N Ne ev ve er r point a jet or hose at people or pets Clip the Setup Pressure Gauge to the hose n...

Страница 11: ...2 Slide Float Closure off of bag figure 3A 3 Hold open edges apart and shake debris from bag figure 3B 4 Slide Float Closure onto bag Sand dense debris Always empty the Viio bag when sand or heavy de...

Страница 12: ...ay not pick up all debris on the first pass but your pool should be clean in 3 hours or less depending on pool size shape and the amount of debris in the pool O Ob bs se er rv ve e V Viiiio o s s o op...

Страница 13: ...s for more frequent Spin Outs If Viio rarely needs to back up and Spin Out near an obstacle then a cam with fewer prongs and less frequent Spin Outs will increase effective cleaning time Changing Spin...

Страница 14: ...if the sweep hose does not move side to side and just drags behind the cleaner check the Sweep Hose for holes Check for debris behind the adjustment screw or in the jet end of the Sweep Hose Sweep Ho...

Страница 15: ...3 Hold open edges apart and shake debris from bag 4 Slide Float Closure onto bag C Cl le ea an ni in ng g t th he e I In n L Li in ne e F Fi il lt te er rs s 1 1 The Hose In Line filter Part Q is loc...

Страница 16: ...set the timer so the Booster Pump will not turn on while the Viio cleaner is out of the pool Never operate the Booster Pump without the cleaner connected 2 Disconnect Wall Quick Connect from the Univ...

Страница 17: ...16 Use Only Genuine Hayward Replacement Parts Troubleshooting For Technical Assistance Call 1 908 355 7995...

Страница 18: ...1 AX6060Z1 Screw 1 4 Type b x 1 1 4 Set of 10 2 AX6060A Pump Volute 3 AX6060UNPAK Union Connector Kit incl 2 ea Union Hose Connector Union Pipe Connector Union Nut and Union O Ring 4 AX6060C Impeller...

Страница 19: ...eep Hose 16 AX6000HWA2V Pressure Hose and Top of In Line Filter Assembly 17 AX6000HFA Hose Swivel Assembly 18 AX6000HE Rigid Hose Pipe Section 2 Rigid Pipes and 1 Coupling 19 AX6000HWA1 Wall Quick Con...

Страница 20: ...ts 3 This Limited Warranty shall not apply to any injury loss damage defect or malfunction of the CLEANER or failure of the CLEANER to function resulting from any failure to operate or maintain the CL...

Страница 21: ...ll of Sale including date of purchase and serial number of the item claimed to be defective the name and address of the PURCHASER and a brief description of the problems defects encountered Call 908 3...

Страница 22: ...P N IS55OOTC Rev B 620 Division Street Elizabeth NJ 07207 Phone 908 351 5400...

Отзывы: