background image

CAUTION - RISK OF EQUIPMENT DAMAGE

3.  Check the water chemistry. The water should be 

properly balanced (pH level), and the pool free from 
algae. Algae can adversely affect the operation and 
performance of the cleaner.

4.  Clean or backwash the filtration system without the 

cleaner in the pool.

The cleaner is not intended to clean the pool after extended 
periods of disuse until the following steps have been taken:

1.  Clear the pool of any large objects that might interfere 

with the cleaner’s operation.

2.  Check to see that the water is at the recommended level.

NEW POOL CONSTRUCTION

POOL PREPARATION

POOLS WITH EXCESSIVE DEBRIS

•  The cleaner should not be used to remove plaster dust or 

construction debris from new or renovated pools.

•  Brush the newly constructed pool surface and vacuum new 

surface debris before installing the cleaner.

•  The cleaner should not be used to remove excessive debris 

before a seasonal pool opening or following a high wind 
event or sandstorm.

•  Pools with excessive amounts of debris should be 

vacuumed manually before using the cleaner.

•  Always empty the cleaner filter cartridges or debris canister 

when filled with debris.

Pool Preparation

•  NEVER SWIM WITH THE CLEANER IN THE POOL.

•  Before using the cleaner, remove any items such as 

thermometers, toys and other accessories from the pool. 
Such items may cause damage to the cleaner or the pool. 
Large debris should also be removed manually from  

      

the pool before installing the cleaner.

•  Chemical balance of water may affect cleaner performance, 

accelerate wear of certain parts, and may lead to more 
frequent maintenance. 

•  DO NOT LEAVE THE CLEANER IN THE POOL WHEN 

CHEMICAL SHOCKING THE POOL.

•  pH should be adjusted and kept between 7.2 – 7.8.

•  Total chlorine should be maintained between 1.0 – 3.0 PPM. 

The cleaner should never be used when chlorine level  
(or other oxidizer) exceeds the normal values.

•  Total alkalinity level should always be maintained  

between 80 – 150 PPM.

•  To keep the pool safe for swimming and protect your 

equipment, have the water tested frequently and balance 
chemicals accordingly.

pH: 7.2 - 7.8
Chlorine: 1.0-3.0 PPM
Total Alkalinity: 80 - 120 PPM

50˚- 100˚F
10˚- 37˚C

Cl

2

>3.0 PPM

Содержание TigerShark Series

Страница 1: ...ll e des Ch nes 01150 St Vulbas France www hayward fr Hayward Pool Products Australia Pty Ltd Melbourne Sydney Brisbane Perth P O Box 4384 Dandenong South VIC 3164 www hayward pool com au Hayward Pool...

Страница 2: ...for personal injury WARNING warns about hazards that could cause serious personal injury death or major property damage and if ignored presents a potential hazard CAUTION warns about hazards that wil...

Страница 3: ...er Water temperature operation range min 50 F 10 C max 95 F 35 C Maximum operating depth 3 m 10 ft Operating the cleaner in temperatures above or below this range may affect performance and cause prem...

Страница 4: ...th excessive amounts of debris should be vacuumed manually before using the cleaner Always empty the cleaner filter cartridges or debris canister when filled with debris Pool Preparation NEVER SWIM WI...

Страница 5: ...should preferably be kept in a shady area and the cooling fan kept unobstructed Leaving the control unit on the pool deck is acceptable but precautions should be taken so it does not get damaged by r...

Страница 6: ...s the depth at the deep end of the pool To reduce cable tangling any excess cable should be coiled and placed next to the control unit To minimize cord twisting completely unroll and straighten the ca...

Страница 7: ...uick Clean model only It is normal for the cleaner to operate in both forward and reverse directions CLEANING CYCLE ON QUIK CLEAN FULL CYCLE 90 min 4 hrs 4 hrs 4 hrs REGULAR MODEL QC MODEL OFF ON ON C...

Страница 8: ...ou may or may not remove the elements for thorough cleaning 4 Using a garden hose with a spray nozzle pressure wash the filter elements to remove debris 5 Wash the inside of the bottom lid 6 Replace t...

Страница 9: ...re it in a protected area For winter storage store the cleaner in a place where it will be protected from cold temperatures Drain the cleaner completely before storage and remove all remaining debris...

Страница 10: ...vy debris Clean the filter It may be clogged Clip the high velocity inlet to the bottom lid This inlet creates extra suction for lifting fine or heavy debris This part also can be helpful if unit beco...

Страница 11: ...rigem Hayward F NF EN C 15 100 GB BS7671 1992 D DIN VDE 0100 702 EW EVHS HD 384 7 702 A VE 8001 4 702 H MSZ 2364 702 1994 MSZ 10 533 1 1990 E UNE 20460 7 702 1993 REBT ITC BT 31 2002 M MSA HD 384 7 70...

Отзывы: