USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 5 of 7
SwimClear™
Rev. A
PLUMBING
1. The union fittings included with the SwimClear
™
are 63 mm union sockets (solvent weld). The 63 mm union fitting is a
pipe socket connection. For 50 mm socket fittings order SP2700UNKIT50. Before solvent cementing fitting onto pipe, do
not forget to place the union nut on the pipe with the threads facing the filter.
2. Refer to fig.1 and 2 for basic suggested piping and valve locations. While systems vary, the main consideration is to
provide the desired control of water flow from the pool to the pump and filter, and back to the pool. When the filter is
located below water level, provide valves to prevent back flow of water to the filter during cleaning and routine servicing.
3. Install face seal, then screw the union nut on to the body to connect the filter to the pump. This connection is the one
above the pump discharge
4. Install face seal, then screw the union nut on to the body to connect the filter to the return pool plumbing.
5. Carefully replace cartridge element into filter body ensuring that the cartridge sits evenly on the collector hub in bottom
of filter body.
6. Place filter head on filter body (being sure filter head O-ring is in place and clean).
7. Tighten lock ring (in clockwise direction) until safety latch fully engages the catch.
8. A 1 ½” NPT filter drain plug is furnished with each filter. When making threaded connections to the filter use plastic
adapters. Apply three turns of PTFE tape (or use special plastic pipe sealant) to male threads. Screw the fitting into the
thread hand tight; then using a strap wrench, tighten one more full turn. Additional tightening is unnecessary and could
result in broken or damaged valve body.
9. A manual air relief valve is furnished to aid in bleeding off unwanted air when starting the filter.
10.
Check for joint leaks before operating.
11. Refer to pump instruction booklet for pump information.
Required clearance
Side
Above
Inches
Cm
Inches
Cm
C100SE
18
45
12
30
C150SE
18
45
15
38
C200SE
18
45
18
45
Figure 3
FILTER MOUNTING
Secure filter to level concrete slab or other rigid surface to meet all local and national codes. Use fasteners appropriate for
the material of the surface being fastened to. Use 2 of the 4 available mounting holes (see fig.1) on opposite corners of the
filter base to ensure the filter is secure and level.
⚠
CAUTION: Be careful not to over tighten the fasteners when mounting the filter. Failure to do so may cause
the base of the filter to crack at the mounting locations causing the filter to be unstable.
STARTING THE FILTER
Be sure filter drain is closed. Open manual air relief valve and open the suction and return valves (when used).
⚠
CAUTION: All suction and discharge valves must be open when starting the system. Failure to do so could
cause severe personal injury and/or property damage. Be sure lock ring is locked and in latched position.
Stand clear of the filter. Prime and start the pump, following the manufacturer’s instructions. Air trapped in the system will
automatically vent to the pool and out the manual air relief valve. Close the air relief valve when a steady stream of water
(not air or air and water) is being discharged.
Содержание Swimclear C100SE