background image

USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS

 2

IMPORTANT SAFETY INSTRUCTIONS

Before installing or servicing this electrical equipment, disconnect it from the power supply

   WARNING   

Read and follow all instructions in this owner’s manual and on 

the equipment. Failure to follow instructions can cause severe 

injury and/or death

 

WARNING –

 This manual contains important information about the installation, operation, and safe use of this pump 

that must be transferred through to the end user of this product.

 

WARNING –

  This product should be installed and serviced only by a qualified professional.

 

WARNING –

  All electrical wiring MUST be performed by a qualified electrical contractor, and must conform to Local/

State/Federal electrical regulations and the Latest Edition of AS/NZS 3000 Wiring Rules.

 

WARNING –

  This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilites, or lack of experience and knowledge, unless they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety. CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY 

DO NOT PLAY WITH THE APPLIANCE.

 

CAUTION –

  This pump is intended for use on permanently installed swimming pools and may also be used with hot 

tubs and spas if so marked. Do NOT use with storable pools. A permanently installed pool is constructed in or on the ground 

or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of 

being readily disassembled for storage and reassembled to its original integrity. Though this product is designed for outdoor 

use, it is strongly advised to protect the electrical components from the weather. Select a well-drained area, one that will 

not flood when it rains. It requires free circulation of air for cooling. Do not install in a damp or non-ventilated location. If 

installed within an outer enclosure or beneath the skirt of a hot tub or spa, adequate ventilation and free circulation of air 

must be provided to prevent overheating of the motor.

 

WARNING –

  Pool and spa components have a finite life. All components should be inspected frequently and replaced 

at least every ten years, or if found to be damaged, broken, cracked, missing, or not securely attached.

 

WARNING –

 

Risk of Electric Shock

. All electrical wiring must be performed by a qualified 

electrical contractor, and must conform to Local/State/Federal electrical regulations and the Latest 

Edition of AS/NZ 3000 Wiring Rules. 

All electrical circuits must be supplied through a Residual 

Current Device - RCD (Safety Switch), with a residual operating current not exceeding 30 mA

Hazardous voltage can shock, burn and cause death or serious property damage. To reduce the risk of 

electric shock, do NOT use an extension cord to connect unit to the electricity supply.

 

WARNING –

  To reduce the risk of electric shock replace damaged wiring immediately. Locate the power cord so that 

it cannot be damaged by lawn mowers, hedge trimmers and other equipment. 

 

WARNING –

  Never operate the circulation system at more than 344 kPa (50 PSI) maximum.

 

WARNING –

  

Automatic Restart.

 The pump motor is automatically protected from overheating. If such an error 

occurs, the pump will automatically restart once the temperature is at a safe level to do so without warning. If a power 

failure occurs while the pump is running, it will automatically restart once the power has been restored.

Содержание Super II SP3000 ECO Series

Страница 1: ...enong South VIC 3164 ABN 66 083 413 414 Sales Contact Ph 1300POOLS1 Fax 1300POOLS2 SAVE THIS INSTRUCTION MANUAL Owner s Manual To prevent potential injury and to avoid unnecessary service calls read t...

Страница 2: ...product is designed for outdoor use it is strongly advised to protect the electrical components from the weather Select a well drained area one that will not flood when it rains It requires free circu...

Страница 3: ...thin the filter upper body All suction and discharge valves MUST BE OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Suc...

Страница 4: ...Install pump on a level concrete slab or other rigid base to meet all local and national codes Secure pump to base with screws or bolts to further reduce vibration and stress on pipe joints The base m...

Страница 5: ...Recommended Hayward recommends that a surge protector device SPD is installed on the feed circuit to the pump by a qualified electrical contractor in accordance with AS NZS 3000 Australian Wiring Rule...

Страница 6: ...ing undiluted chemicals directly to the skimmer or strainer basket may damage the pump and voids warranty Starting The Pump To start the pump make sure all the suction and discharge valves are open an...

Страница 7: ...ramic seat with rubber cup out of the seal plate Item 23 If tight use a small screwdriver to tap the seal out from the back side of the seal plate 3 Remove the slinger from the motor shaft Item 22 IMP...

Страница 8: ...00Q6DI SPX1500Q6DI SPX1500Q6DI SPX1500Q6DI SPX1500Q6DI SLINGER 1 SPX3020AUHDI SPX3020AUHDI SPX3020AUHDI SPX3020AUHDI 22 R DESCRIPTION DATE BY APPD Ref No SIIE 320 SIIE 350 SIIE 430 SIIE 530 SIIE 580 D...

Страница 9: ...place the cartridge as per manufacturer s instructions 4 An air leak in the suction side plumbing bubbles issuing from the return fittings Re tighten or re seal threaded suction fittings with Teflon t...

Страница 10: ...4 34 70 13 4 IPX5 SIIE 350 1 25 17 5 m 172 kPa 1 1 5 1 70 15 3 IPX5 SIIE 430 1 5 17 5 m 172 kPa 1 38 6 23 70 15 3 IPX5 SIIE 530 2 20 9 m 205 kPa 1 86 8 33 70 19 05 IPX5 SIIE 580 3 22 7 m 223 kPa 2 33...

Страница 11: ...ds or supplying equivalent Goods or Services again 3 Paying the cost of replacing the Goods or of supplying equivalent Goods or Services again or 4 Paying the costs of repairing the Goods Claims made...

Страница 12: ...urne Sydney Brisbane Perth Email sales hayward pool com au Website www hayward pool com au PO Box 4384 Dandenong South VIC 3164 ABN 66 083 413 414 Sales Contact Ph 1300POOLS1 Fax 1300POOLS2 Hayward an...

Отзывы: