background image

USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS

Hayward Pool Products (Australia) Pty Ltd.

Melbourne-Sydney-Brisbane-Perth

Email: [email protected] | Website: www.hayward-pool.com.au

PO Box 4384 | Dandenong South VIC 3164 

ABN 66 083 413 414

Sales Contact Ph: 1300POOLS1 Fax: 1300POOLS2 

SAVE THIS INSTRUCTION MANUAL 

Owner’s Manual

To prevent potential injury and to avoid unnecessary service 

calls, read this manual carefully and completely.

30-LITINSB022RA

R

8.635

9.458

7.625

12.149

18.866

13.817

24.348

10.358

8.154

10.392

10.017

REVISIONS

REV. DESCRIPTION

DATE

FAI / NCMR

PCD / PLM

BY

APPD

D

C

B

A

B

C

D

1

2

3

4

5

6

7

8

8

7

6

5

4

3

2

1

E

F

E

F

A

SHEET 1 OF 1

2017/8/18

MODELED

WEIGHT:

COLOR:

2017/1/10

SCALE: 1:1

REV

DWG.  NO.

E

SIZE

DESCRIPTION:

NAME

DATE

Q.A.

MFG APPR.

ENG APPR.

CHECKED

DRAWN

             

             

             

             

             

             

             

             

MATERIAL:

SEE PART DRAWINGS

UNAUTHORIZED USE, MANUFACTURE, OR REPRODUCTION IN WHOLE OR IN PART IS PROHIBITED.  DRAWING, DESIGN, AND OTHER DISCLOSURES ARE PROPERTY OF:  HAYWARD POOL PRODUCTS

74.44 LBS.

SEE PART DRAWINGS

STATUS:

SP3000 ECO Series

Super II ECO Single Speed Pump

Содержание Super II SP3000 ECO Series

Страница 1: ...enong South VIC 3164 ABN 66 083 413 414 Sales Contact Ph 1300POOLS1 Fax 1300POOLS2 SAVE THIS INSTRUCTION MANUAL Owner s Manual To prevent potential injury and to avoid unnecessary service calls read t...

Страница 2: ...product is designed for outdoor use it is strongly advised to protect the electrical components from the weather Select a well drained area one that will not flood when it rains It requires free circu...

Страница 3: ...thin the filter upper body All suction and discharge valves MUST BE OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Suc...

Страница 4: ...Install pump on a level concrete slab or other rigid base to meet all local and national codes Secure pump to base with screws or bolts to further reduce vibration and stress on pipe joints The base m...

Страница 5: ...Recommended Hayward recommends that a surge protector device SPD is installed on the feed circuit to the pump by a qualified electrical contractor in accordance with AS NZS 3000 Australian Wiring Rule...

Страница 6: ...ing undiluted chemicals directly to the skimmer or strainer basket may damage the pump and voids warranty Starting The Pump To start the pump make sure all the suction and discharge valves are open an...

Страница 7: ...ramic seat with rubber cup out of the seal plate Item 23 If tight use a small screwdriver to tap the seal out from the back side of the seal plate 3 Remove the slinger from the motor shaft Item 22 IMP...

Страница 8: ...00Q6DI SPX1500Q6DI SPX1500Q6DI SPX1500Q6DI SPX1500Q6DI SLINGER 1 SPX3020AUHDI SPX3020AUHDI SPX3020AUHDI SPX3020AUHDI 22 R DESCRIPTION DATE BY APPD Ref No SIIE 320 SIIE 350 SIIE 430 SIIE 530 SIIE 580 D...

Страница 9: ...place the cartridge as per manufacturer s instructions 4 An air leak in the suction side plumbing bubbles issuing from the return fittings Re tighten or re seal threaded suction fittings with Teflon t...

Страница 10: ...4 34 70 13 4 IPX5 SIIE 350 1 25 17 5 m 172 kPa 1 1 5 1 70 15 3 IPX5 SIIE 430 1 5 17 5 m 172 kPa 1 38 6 23 70 15 3 IPX5 SIIE 530 2 20 9 m 205 kPa 1 86 8 33 70 19 05 IPX5 SIIE 580 3 22 7 m 223 kPa 2 33...

Страница 11: ...ds or supplying equivalent Goods or Services again 3 Paying the cost of replacing the Goods or of supplying equivalent Goods or Services again or 4 Paying the costs of repairing the Goods Claims made...

Страница 12: ...urne Sydney Brisbane Perth Email sales hayward pool com au Website www hayward pool com au PO Box 4384 Dandenong South VIC 3164 ABN 66 083 413 414 Sales Contact Ph 1300POOLS1 Fax 1300POOLS2 Hayward an...

Отзывы: