NOTE:
If the pool does not have new water, add 1 liter of metal remover and 1 liter of non-copper based algaecide to the
pool, per manufacturer’s instructions. This ensures a quick, trouble free transfer to the Salt & Swim 3C system.
Salt & Swim 3C Installation
Follow the step by step instructions located on the Installation Quick Start Guide. Refer to the following sections for more
detailed information.
Mounting the Salt & Swim 3C Control Box
The Salt & Swim 3C is contained in a raintight enclosure that is suitable for outdoor mounting. The Control Box must be
mounted a minimum of 3.5 meters (12 ft.) horizontal distance (or more, if local codes require) from the pool, within 2 meters
from a protected outlet, and within 4.5 meters (15 ft.) from where the Cell is installed.
The Control Box is designed to mount vertically on a flat surface with the cables facing downward. Because the enclosure
also acts as a heat sink (disperses heat from inside the box), it is important not to block the four sides of the Control Box.
Do not mount Salt & Swim 3C inside a panel or tightly enclosed area.
Before securing the Control Box to the intended location, make sure that the power cord will reach the protected outlet and
that the Cell cable will reach the location where the Cell Vessel will be installed. Use the included Mounting Template to
position the fasteners to the mounting surface. Refer to the diagram below.
MOUNTING TEMPLATE
Use the included hardware or your own hardware
(suitable for a 20lb load) to mount the Control Box
to a wall or post within 3 feet of a GFCI outlet,
making sure that the cord will reach. Use this
template to locate and drill fastener holes.
09
2xx
x
After mark ing the mounting
surface with this template,
screw in top fasteners leaving
1/8” space between
screw head and surface
Hang Control Box
on fasteners
Screw in bottom fasteners securely
Use to mount
on flat surfa ce
Use to mount
on flat surfa ce
Use t o mount
on post
Use t o mount
on post
1
3
2
4
Plumbing
The Cell Vessel is designed to install in either 50 mm or 63 mm (1½” or 2”) PVC pool plumbing. The Cell Vessel must be
installed on a 25 cm (10 in) run of straight pipe at the end of the return piping just before the water returns to the pool. All pool
equipment should be upstream from the Cell Vessel. It must be located within 4.5 meters (15 ft.) of where the Control Box is
mounted. Also, there must be enough clearance to insert and remove the Cell from the Vessel after the Vessel is installed.