Hayward Salt & Swim 3C Pro Скачать руководство пользователя страница 20

 

N’UTILISEZ QUE DES PIÈCES DÉTACHÉES D’ORIGINE HAYWARD 

Page 20 

Salt & Swim

 3C 

Merci d’avoir choisi Hayward. Ce manuel contient des informations importantes relatives au

fonctionnement et à l’entretien de votre produit. Le conserver pour vous y reportez ultérieurement.

POUR ENREGISTRER VOTRE PRODUIT SUR NOTRE BASE DE DONNEES,

ALLEZ SUR :

www.haywardpool.ca

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Enregistrer les informations suivantes pour référence ultérieure, le cas échéant :

1)  Date d’Achat_________________________________________________________

2)  Nom Complet ________________________________________________________

3)  Addresse ______________________________________________________________

4)  Code postal______________________________________________________________

 

5)  Adresse Email__________________________________________________________

6)  Numéro de la pièce______________________Numéro de Série__________________________

7)  Vendeur de la Piscine____________________________________________________________

8) Adresse_______________________________________________________________

9)  Code postal____________________Pays____________________________________

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Pour votre information

Note

ENREGISTREMENT

Содержание Salt & Swim 3C Pro

Страница 1: ...S GUIDE SAVE THIS OWNER S MANUAL HAYWARD POOL PRODUCTS CANADA INC 2880 Plymouth Drive Oakville ON L6H 5R4 855 429 9274 HAYWARDPOOL CA 092520 RevA CM C L I S T E D INTERTEK US C 3101970 Conforms to UL...

Страница 2: ...to electric supply provide a properly located outlet WARNING Read and follow all instructions in this owner s manual and on the equipment Failure to follow instructions can cause serious injury or de...

Страница 3: ...lete Name ________________________________________________________ 3 Address ______________________________________________________________ 4 Postal code_______________________________________________...

Страница 4: ...e used around a saline pool with electronic chlorine generator in your particular location and circumstances NOTE The use of dry acid sodium bisulfate to adjust pool pH is discouraged especially in ar...

Страница 5: ...the Cell cable will reach the location where the Cell Vessel will be installed Use the included Mounting Template to position the fasteners to the mounting surface Refer to the diagram below MOUNTING...

Страница 6: ...ting Template is the same width as the Cell Vessel The entire Cutting Template must fit on the pipe otherwise the Cell Vessel will not fit With the Cutting Template secure on the pipe mark all 10 cuto...

Страница 7: ...e Inspection marks can be seen the pipe has not been inserted far enough into the Cell Vessel 6 7 Remove the foam protector from the Cell Verify that the O Ring is attached before inserting the Cell i...

Страница 8: ...re that the Cell s flow switch is properly initialized This will occur just once when a new Cell is installed After the flow switch is initialized the Salt Swim 3C will not perform this procedure agai...

Страница 9: ...3C chlorine generator CHEMICAL IDEAL LEVELS Salt 2 7 to 3 4 g l Free Chlorine 1 0 to 3 0 ppm pH 7 2 to 7 8 Cyanuric Acid Stabilizer 20 to 30 ppm 25 ppm best Add stabilizer only if necessary Total Alka...

Страница 10: ...y to the addition of water because of splashing backwashing or draining because of rain Salt is not lost due to evaporation Type of Salt to Use It is important to use only sodium chloride NaCl salt th...

Страница 11: ...75 19 800 82 5 21 800 90 23 700 97 5 25 800 105 27 700 112 5 29 700 120 31 700 127 5 33 700 135 35 700 142 5 37 600 150 39 600 0 ppm 0 75 0 94 1 13 1 34 1 53 1 69 1 91 2 09 2 28 2 47 2 66 2 84 3 03 3...

Страница 12: ...w flow through the cell The pool filter pump could be in its off cycle If this is not the case refer to the Troubleshooting section in this manual Blinks when performing the Flow Switch Calibration pr...

Страница 13: ...nor infrequent adjustments Because the chlorine demand of the pool increases with temperature most people find they have to adjust up at the peak of the summer and down during colder periods The Salt...

Страница 14: ...ns The Salt Swim 3C s various LEDs show the operation status as well as alert the user to any problems that may have occurred Some indications may require a combination of LEDs to illuminate To aid in...

Страница 15: ...Salt Swim 3C may display an error by illuminating the PROBLEM DETECTED LED and blinking one of the DAILY CHLORINE OUTPUT LEDs There are ten DAILY CHLORINE OUTPUT LEDs that each indicate a different e...

Страница 16: ...ave not been altered in any way and provided that they have been used exclusively with HAYWARD parts and components The warranty does not cover damage due to frost and to chemicals Any other costs tra...

Страница 17: ...Hayward is a registered trademark of Hayward Industries Inc 2011 Hayward Industries Inc...

Страница 18: ...ILSATEUR CONSERVEZ CE MANUEL D UTILISATION 092520 RevA CM C L I S T E D INTERTEK US C 3101970 Conforms to UL 1081 and CSA C22 2 218 1 HAYWARD POOL PRODUCTS CANADA INC 2880 Plymouth Drive Oakville ON L...

Страница 19: ...ecteur Utiliser une prise murale AVERTISSEMENT Lire attentivement et respecter les instructions de ce manuel et celles figurant sur l appareil Le non respect de ces instructions peut tre l origine de...

Страница 20: ...______________________ 2 Nom Complet ________________________________________________________ 3 Addresse ______________________________________________________________ 4 Code postal___________________...

Страница 21: ...n d acide sec bisulfite de sodium pour ajuster le pH de la piscine est d conseill e en particulier dans les r gions arides o l eau de la piscine est expos e une vaporation importante et n est pas cour...

Страница 22: ...tallation du Boitier de la Cellule Utiliser le Gabarit de Montage pour positionner les attaches sur la surface de montage Voir le sch ma ci dessous MOUNTING TEMPLATE Use theincludedhardware or your ow...

Страница 23: ...D coupe doit s adapter sur le tuyau sinon le Boitier de la Cellule ne sera pas bien positionn Lorsque le Gabarit de d coupe est bien en place sur le tuyau marquer les 10 d coupes sur le tuyau l aide...

Страница 24: ...ns r suffisamment profond ment dans le Boitier de la Cellule 6 7 Retirer la mousse de protection de la Cellule V rifier que le Joint Torique est fix avant d ins rer la Cellule dans le Boitier de Cellu...

Страница 25: ...le d tecteur de d bit de la Cellule est correctement initialis Ceci ne se produit qu une seule fois quand on installe une nouvelle Cellule Lorsque le d tecteur de d bit est initialis le Salt Swim 3C...

Страница 26: ...u fournisseur que vous utilisez un g n rateur de chlore Salt Swim 3C CHIME CONCENTRATIONS IDEALES Sel 2 7 3 4 g L Chlore libre 1 0 3 0 ppm pH 7 2 7 8 Acide cyanurique Stabilisateur 20 30 ppm 25 ppm de...

Страница 27: ...ne vidange en raison de la pluie Il n y a pas de perte de sel par vaporation Type de sel utiliser N utiliser que du chlorure de sodium NaCl dont la puret est sup rieure 99 Il s agit de sel de la quali...

Страница 28: ...900 60 15 850 67 5 17 800 75 19 800 82 5 21 800 90 23 700 97 5 25 800 105 27 700 112 5 29 700 120 31 700 127 5 33 700 135 35 700 142 5 37 600 150 39 600 0 ppm 0 75 0 94 1 13 1 34 1 53 1 69 1 91 2 09 2...

Страница 29: ...IBLE DANS LA CELLULE LA POMPE FILTRATION DE LA PISCINE PEUT SE TROUVER EN CYCLE OFF SI C EST LE CAS VOIR LA SECTION RECHERCHE DE PANNES DANS LE PR SENT MANUEL CLIGNOTE PENDANT LA PROC DURE D TALONNAGE...

Страница 30: ...chlore tous les deux ou trois jours et ajuster le r glage en cons quence 2 ou 3 trois ajustements sont g n ralement n cessaires pour trouver le r glage optimal de votre piscine par la suite le chlori...

Страница 31: ...rnales et il n est pas n cessaire de les d monter D marrage de printemps NE PAS mettre en marche Le Salt Swim 3C sans avoir v rifi l quilibre chimique de l eau Voir le chapitre Composition chimique de...

Страница 32: ...CELLULE FAIBLE s allume La dur e de service de la Cellule est arriv e son terme Elle doit tre remplac e d s que possible 6 La LED PROBLEME D TECT s allume ET une LED PRODUCTION JOURNALI RE DE CHLORE c...

Страница 33: ...comporter que des pi ces et composants d origine La garantie ne couvre pas les dommages dus au gel et aux produits chimiques Tous les autres co ts transport main d oeuvre etc sont exclus de la garant...

Страница 34: ...Hayward is a registered trademark of Hayward Industries Inc 2011 Hayward Industries Inc Hayward est une marque d pos e de Hayward Industries Inc 2011 Hayward Industries Inc...