Chlorinator Diagnostics
For the chlorinator to be operating, several conditions must exist: the filter pump must be running, the flow switch must detect flow, the chlorinator setting must
be greater than 0%, the water temperature at the cell must be between 50ºF and 140ºF (superchlorinate will run under 50º except during freeze protection),
and the salt level must be within the operating range. If any of these conditions are not met, the diagnostic screen will show that the chlorinator is off. Also,
depending on the chlorinator setting, the OmniPL may be in between cycles and the chlorinator is at rest (cell current shows 0.00A). To force the start of the
new cycle, you can touch the Reverse Polarity button.
NOTE: If a conventional or solar heater is operating, it is likely that the temperature of the water at the cell is higher than the pool/spa water temperature dis-
played on the OmniPL default display.
Restart Average Salt -
The OmniPL monitors salt level while chlorinating. At any time, go to the chlorinator diagnostic screen to view the average salt based
on an ongoing calculated average. If you restart average salt, the previous average is deleted and the OmniPL begins calculating the new average from that
moment. The OmniPL will start with the instant salt reading and calculate an ongoing average.
Reverse Polarity
- The OmniPL periodically reverses the polarity of the voltage applied to the chlorinator cell in order to automatically clean off any calcium
deposits. To check operation in both polarities, touch this button. The chlorinator will turn off, wait for 15 seconds and then turn on in the opposite polarity.
Reset Cell Maintenance Timer
- To maintain maximum performance, it is recommended that you open and visually inspect the chlorinator cell every 3 months
or after cleaning your filter. The OmniPL will remind you to do this by displaying a message to clean and inspect the cell after approximately 500 hours of opera-
tion. You can restart the timer by touching this button.
POOL
diagnostic
+/-
00.00
diagnostic
cell temp range: 50 - 120ºF
cell temp: 62.8ºF
instant salt: 2800 ppm
average salt: 3200 ppm
salt monitoring: standard
cell type: T-Cell-15
cell voltage: 27.49 V
cell current: 5.09 A
board temp: 100.4 ºF
relay polarity: K2
Reset Cell Maintenance Timer
- Touch to
restart the timer.
Reverse Polarity
- Touch this button to
reset the average salt reading.
Restart Average Salt
- Touch this button
to delete the existing average salt reading.
The OmniPL will restart a new calculation
using the instant salt level.
ON
15%
POOL
chlorinator
3200 ppm
average
SC
POOL
diagnostic
+/-
00.00
diagnostic
cell temp range: 50 - 120ºF
cell temp: 62.8ºF
instant salt: 2800 ppm
average salt: 3200 ppm
salt monitoring: standard
cell type: T-Cell-15
cell voltage: 27.49 V
cell current: 5.09 A
board temp: 100.4 ºF
relay polarity: K2