Heat Pump Pool / Spa Heater Owner’s Manual
21
Wiring Recommendations
Note:
It is not necessary to remove the entire front panel to make
electrical connections. Doing so can damage sensitive electronic
controls and can void the warranty.
DO NOT TOUCH OR ALLOW LOOSE WIRES TO TOUCH THE
THERMOSTAT CIRCUIT BOARDS DURING INSTALLATION.
HP-
4**
HP-
5**
PE-
42**
PE-
52**
Min Wire
Ga.
10
8
10
8
Min. Wire
Ga. For
runs over
50 ft.
10
6
10
6
Wire alloy
Copper
Copper
Copper
Copper
Fuse-
HACR or
Time
Delayed
30
50
30
50
Power
consumption
–Watts
3450
5800
3450
5800