With power off, measure resistance, comparing
each terminal to ground. IF any terminal shows
continuity, replace the gas valve (
pg. 20
). IF OK, go
to step 3F.
ICB wiring
Inspect ICB wiring. IF wiring is damaged, replace
the wire harness with a new wire harness kit (
pg.
20
). IF OK and the problem still exists, replace the
ICB (
pg. 20
)
Verify gas valve is not shorted
Step 3E
31
Step 3F
3. Open FC3 &/or F1 Fuse (cont.)
When testing the gas valve, if continuity appears between any wires and ground, then
this implies a short has occurred and the gas valve will need to be replaced (refer to
pg. 20 for part number).
Содержание H150FDN
Страница 12: ...Universal H Series Heaters How To ...
Страница 18: ...Universal H Series Heaters Troubleshooting ...
Страница 64: ...64 ...