ELECTRICAL RATINGS:
All wiring must conform to local and NEC/CEC codes. Copper wire only.
PRECAUTION: Connect only to a circuit protected by a class-A ground fault interrupter.
Power:
110-130VAC, 2A, 50/60Hz or 220-250VAC, 1A, 50/60Hz.
Timer: Connect to load side. Remote Control unit: Connect to line
power
{Diagram}
ENCLOSURE 3 – SUITABLE FOR INDOOR OR OUTDOOR MOUNTING.
Goldline Controls, Inc.
Registration# 28325
A Hayward Company
Pest Control Products Act
61 Whitecap Drive
DOMESTIC
North Kingstown, RI. 02852
USA
2580 Plymouth Dr.
Oakville, Ontario L6H 5R4
C-UL Listed 6D22 NSF Certified to ANSI/NSF STANDARD 50 Swimming Pool and Spa
Chlorinator
LED Indicator
Flashing
Continuous
Power
Power is present.
Generating
Water is too hot or too cold to operate
Chlorine is being produced
Super Chlorinate
Super Chlorinate—Chlorine generation is at
100% regardless of “Desired Output”
setting.
Remotely Controlled
Remote Control is in Service or Time-Out
mode—the AquaRite CUL Electrolytic
Chlorine Generator switch and dial
temporarily control operation.
Remote control system is controlling the
operation of the AquaRite CUL Electrolytic
Chlorine Generator.
No Flow
Time Delay after flow is established.
Water is NOT flowing through the AquaRite
CUL Electrolytic Chlorine Generator
cell— Chlorine generation is halted.
Check Salt
Salt is below 2600 ppm. AquaRite CUL
Electrolytic Chlorine Generator is working at
reduced efficiency. Check AquaRite CUL
Electrolytic Chlorine Generator cell and
clean if necessary. If problem persists, have
the salt level professionally tested before
adding salt to the pool.
Salt is below 2300 ppm. Chlorine generation
is halted. Check AquaRite CUL Electrolytic
Chlorine Generator cell and clean if
necessary. If problem persists, have the salt
level professionally tested before adding salt
to the pool.
High Salt
Cell current too High. Chlorine generation is
halted. See owner’s manual for directions on
decreasing salt level.
Inspect Cell
Reduced AquaRite CUL Electrolytic
Chlorine Generator cell efficiency or
scheduled 3 month cell inspection time.
Inspect AquaRite CUL Electrolytic Chlorine
Generator cell and clean if necessary, and
press display button for 3 seconds to turn off
flashing indicator.
AquaRite CUL Electrolytic Chlorine
Generator Cell efficiency greatly reduced.
Inspect AquaRite CUL Electrolytic Chlorine
Generator cell and clean if necessary. If
AquaRite CUL Electrolytic Chlorine
Generator cell is clean it may be at the end
of it’s life and needs to be replaced.
Inspect AquaRite CUL Electrolytic Chlorine Generator cell every 3 months/clean if necessary