background image

ELECTRICAL RATINGS:

 

All wiring must conform to local and NEC/CEC codes. Copper wire only. 

 

PRECAUTION: Connect only to a circuit protected by a class-A ground fault interrupter. 

 

Power: 

110-130VAC, 2A, 50/60Hz or 220-250VAC, 1A, 50/60Hz. 
Timer: Connect to load side. Remote Control unit: Connect to line 
power 

 

{Diagram} 

ENCLOSURE 3 – SUITABLE FOR INDOOR OR OUTDOOR MOUNTING. 

 

Goldline Controls, Inc. 

Registration# 28325 

A Hayward Company 

Pest Control Products Act 

61 Whitecap Drive 

DOMESTIC 

North Kingstown, RI. 02852 
USA 

2580 Plymouth Dr. 
Oakville, Ontario L6H 5R4 

 

C-UL Listed 6D22 NSF Certified to ANSI/NSF STANDARD 50 Swimming Pool and Spa 
Chlorinator 

 
 

LED Indicator 

Flashing 

Continuous 

 

Power

 

 

Power is present.

 

 

 

 

Generating

 

Water is too hot or too cold to operate

 

Chlorine is being produced

 

 

Super Chlorinate

 

 

Super Chlorinate—Chlorine generation is at 
100% regardless of “Desired Output” 
setting.

 

 

Remotely Controlled

 

Remote Control is in Service or Time-Out 
mode—the AquaRite CUL Electrolytic 
Chlorine Generator switch and dial 
temporarily control operation.

 

 

Remote control system is controlling the 
operation of the AquaRite CUL Electrolytic 
Chlorine Generator.

 

 

No Flow

 

 

Time Delay after flow is established.

 

Water is NOT flowing through the AquaRite 
CUL Electrolytic Chlorine Generator 

cell— Chlorine generation is halted.

 

 

 
 

Check Salt

 

Salt is below 2600 ppm. AquaRite CUL 
Electrolytic Chlorine Generator is working at 
reduced efficiency. Check AquaRite CUL 
Electrolytic Chlorine Generator cell and 
clean if necessary. If problem persists, have 
the salt level professionally tested before 
adding salt to the pool.

 

Salt is below 2300 ppm. Chlorine generation 
is halted. Check AquaRite CUL Electrolytic 
Chlorine Generator cell and clean if 
necessary. If problem persists, have the salt 
level professionally tested before adding salt 
to the pool.

 

 

High Salt

 

 

Cell current too High. Chlorine generation is 
halted. See owner’s manual for directions on 
decreasing salt level.

 

 

 
 

Inspect Cell

 

Reduced AquaRite CUL Electrolytic 
Chlorine Generator cell efficiency or 
scheduled 3 month cell inspection time. 
Inspect AquaRite CUL Electrolytic Chlorine 
Generator cell and clean if necessary, and 
press display button for 3 seconds to turn off 
flashing indicator.

 

AquaRite CUL Electrolytic Chlorine 
Generator Cell efficiency greatly reduced. 
Inspect AquaRite CUL Electrolytic Chlorine 
Generator cell and clean if necessary. If 
AquaRite CUL Electrolytic Chlorine 
Generator cell is clean it may be at the end 
of it’s life and needs to be replaced.

 

 

Inspect AquaRite CUL Electrolytic Chlorine Generator cell every 3 months/clean if necessary 

Содержание Goldline Controls Aquarite-CUL

Страница 1: ...2019 2626 2019 10 10 Part No AQ RITE CUL Aqua rite CUL Electrolytic Chlorine Generator DOMESTIC READ THE LABEL AND MANUAL BEFORE USING REGISTRATION NUMBER 28325 PEST CONTROLS PRODUCT ACT ...

Страница 2: ...for the AquaRite CUL Electrolytic Chlorine Generator This cell must only be used on this model of chlorine generating device Read the label the Installation and Operation Manual of the AquaRite CUL Electrolytic Chlorine Generator before using C UL Listed 6D22 NSF Certified to ANSI NSF Standard 50 Swimming Pool and Spa Chlorinator ...

Страница 3: ...output of hypochlorous acid equivalent to 0 45 kg of chlorine per day Do not use this device with bromide products KEEP OUT OF REACH OF CHILDREN NOTICE TO USER This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Products Act to use this product in a way that is inconsistent with the directions on the label SWITCH The s...

Страница 4: ... NOT flowing through the AquaRite CUL Electrolytic Chlorine Generator cell Chlorine generation is halted Check Salt Salt is below 2600 ppm AquaRite CUL Electrolytic Chlorine Generator is working at reduced efficiency Check AquaRite CUL Electrolytic Chlorine Generator cell and clean if necessary If problem persists have the salt level professionally tested before adding salt to the pool Salt is bel...

Страница 5: ...LGAE in Residential Swimming Pools and Spas DOMESTIC READ THE LABEL AND MANUAL BEFORE USING REGISTRATION NUMBER 28325 PEST CONTROL PRODUCTS ACT Goldline Controls Inc A Hayward Company 61 Whitecap Drive North Kingstown RI 02852 USA Hayward Pool Products Canada 2880 Plymouth Drive Oakville ON L6H 5R4 905 829 2880 ...

Страница 6: ... USER This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Products Act to use this product in a way that is inconsistent with the directions on the label WARNING Heavy pool or spa usage and higher temperature may require higher chlorine output to maintain proper free available chlorine residuals Follow all aspects of t...

Страница 7: ...Table of Contents OPERATION General 1 Water Chemistry 1 Controls 6 Maintenance 8 INSTALLATION Mounting 9 Plumbing 10 Wiring 11 TROUBLESHOOTING Troubleshooting 14 WARRANTY Warranty 16 ...

Страница 8: ...d to properly sanitize a pool varies due to bather load rainfall temperature and the pool s cleanliness Water Chemistry The table below summarizes the recommended water parameters The only special requirements for the AquaRite CUL Electrolytic Chlorine Generator are the salt level and stabilizer It is important to maintain these levels in order to prevent corrosion or scaling and to ensure maximum...

Страница 9: ...the pool water balance Your water is properly balanced if the Si is 0 2 If the Si is below 0 2 the water is corrosive and plaster pool walls will be dissolved into the water If the Si is above 0 2 scaling and staining will occur Use the chart below to determine the saturation index Si pH Ti Ci Ai 12 1 Diagram Diagram ...

Страница 10: ... to the addition of water because of splashing backwashing or draining because of rain Salt is not lost due to evaporation Type of Salt to Use It is important to use only sodium chloride NaCl salt that is greater than 99 pure This is common food quality or water softener salt and is usually available at building supply stores in 18 36 Kg 40 80 lb bags labeled Coarse Solar Salt It is also acceptabl...

Страница 11: ... Diagram 4 ...

Страница 12: ... Diagram 5 ...

Страница 13: ...bove REMOTELY CONTROLLED When illuminated indicates that a remote pool automation control Goldline Aqua Logic Pentair Intellitouch Polaris Eos etc is controlling the AquaRite CUL Electrolytic Chlorine Generator the main switch and Desired Output adjustment are inactive When flashing the Aqua Logic Intellitouch or Eos is in SERVICE or TIME OUT mode and the Main Switch and Desired Output adjustment ...

Страница 14: ...onger to generate enough chlorine To find the optimum Desired Output setting start at approximately 50 Test the chlorine level every few days and adjust the dial up or down accordingly It usually takes 2 3 adjustments to find the ideal setting for your pool spa and after that it should only take minor infrequent adjustments Because the chlorine demand of the pool increases with temperature most pe...

Страница 15: ... an unusually high calcium level in the pool old pool water is usually the cause If this is not corrected you may to have to periodically clean the AquaRite CUL Electrolytic Chlorine Generator cell The simplest way to avoid this is to bring the pool chemistry to the recommended levels as specified Mild Acid Washing Use only in severe cases where flushing and scraping will not remove the majority o...

Страница 16: ...aRite CUL Electrolytic Chlorine Generator system Mounting the AquaRite CUL Electrolytic Chlorine Generator Control The AquaRite CUL Electrolytic Chlorine Generator is contained in a raintight enclosure that is suitable for outdoor mounting The control must be mounted a minimum of 2 meters 5 ft horizontal distance or more if local codes require from the pool spa The control is designed to mount ver...

Страница 17: ...enerator cell Configurations 2 and 3 allow for chlorination of both the pool and spa during spa spillover operation but prevent over chlorination of the spa during spa only operation Never use configuration 4 Diagram Flow Switch IMPORTANT There must be at least a 25cm 12 straight pipe run before upstream the flow switch If the switch is plumbed after the AquaRite CUL Electrolytic Chlorine Generato...

Страница 18: ...enerator shall be connected to a circuit protected by a class A ground fault interrupter Be sure to connect the ground wire to the green ground screw terminal located on the bottom of the enclosure Diagram Bonding A lug used for bonding is attached to the bottom of the AquaRite CUL Electrolytic Chlorine Generator enclosure see diagram below The AquaRite CUL Electrolytic Chlorine Generator must be ...

Страница 19: ...to 152 meters 500 feet apart Any outdoor rated 4 conductor cable can be used Refer to each manufacturer s instructions and the wiring diagrams below for proper wiring connection to the AquaRite CUL Electrolytic Chlorine Generator NOTE There must be only 1 primary unit All other AquaRite CUL Electrolytic Chlorine Generator units must be configured as secondary Diagram Pentair Attach wires to opposi...

Страница 20: ...Polaris Attach wires to proper screw terminals as shown below Note that screw terminal 1 is marked on the Polaris PCB Diagram 13 ...

Страница 21: ...e button is not pushed for 30 seconds the display will revert back to the standard salt display Common Problems and Solutions 1 Power LED not on Check to make sure either 120VAC or 240VAC input power is connected to the proper screw terminals at the AquaRite CUL Electrolytic Chlorine Generator control Verify input voltage with a voltmeter If there is input power the fuse may have blown The AquaRit...

Страница 22: ...ated the cell may be worn and need replacement 8 Possible causes of little or no free chlorine residual AquaRite CUL Electrolytic Chlorine Generator switch in OFF position Desired Output adjustment setting is too low Low stabilizer Cyanuric Acid Filter pump time too short 8 hours for average size pools more for large pools Salt level too low below 2500 ppm Check Salt LED on Salt level too high Hig...

Страница 23: ...y pool automation or chlorination product or part with a part number other than AQRITE AQ TROL AQ LOGIC AQL P AQL PS or AQL CL to be free from defects in material or workmanship under normal use and service for one year from date of the initial system installation provided it is installed in accordance with the Goldline installation instructions and specifications provided with the product If writ...

Страница 24: ... Diagram Goldline Controls Inc A Hayward Company N Kingstown RI 02852 USA 888 921 POOL 7665 092009 Copyright 2004 Goldline Controls Inc ...

Страница 25: ......

Отзывы: