Page 23
Fig 46
Fig 47
15.
At this point you will be asked to enable or disable the Low
Temp Operation (Default is Disabled) by pressing the &
buttons.(
fig 46).
Enabling this feature will turn on the
EcoStar, if stopped, to protect the drive. Press the
button to continue.
16.
If the Low Temp Operation is enabled you will be asked to
set the Low Temp Speed (
fig 47). T
he default is 1000 rpm
(29%). This speed can be adjusted between 600 rpm
(17%) and 3450 rpm (100%) by pressing the &
buttons. Press the button to continue.
Fig 48
Note: Low Temp operation is for
drive protection only
Programming-Configuration
17.
In this screen you will be asked to set the Drive Temp
Setting
(fig 48).
Default is 41º F. This Temperature can be
adjusted between 35.6 and 50º F by pressing the &
buttons. Press the button to continue. Setting will show
in both “C” and “F”.