Software versions necessary to operate the EcoStar
Aqua Logic/Pro Logic/Aqua Plus v2.65 or higher
OnCommand 1.00 or higher
E-Command 4
(Original E-Command not compatible) v2.80 or higher
1.
Maximum 500’ for data cable. The data cable needs to be run through the second (data) conduit opening and channel
(Page 8).
2.
Remove the two data plugs (COMBUS & DISPLAY) from the wiring compartment
(fig 23)
and the 4 connector data plug from
the controller
(fig 22).
Wire 7 on the pump to 2 on the controller, 8 on the pump to 3 on the controller and 1 on the pump to 4 to
the controller as shown
(fig 22 & 23).
Reinstall plugs. Wire colors can be different as those shown as long as they match point to
point.
Control
Data Plug
Figure 23
Figure 22
Page 10
8
7
2
3
1
4
Installation-Hayward/Goldline Controls
(Compatible software shown below)
Note: When connecting high voltage for an EcoStar that is data connected to a Hayward/Goldline control, voltage
needs to come directly from a breaker in the control, or in the case of an OnCommand, directly from the main or
sub-panel and not from the filter pump relay.
Note: Wire from
4 on Remote
display to 1 on
EcoStar is not
needed in units
Mfg 5/19/11
going forward