USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Hayward is a registered trademark and AquaRite

is a trademark of Hayward Industries, Inc. © 2021 Hayward Industries, Inc.

All other trademarks not owned by Hayward are the property of their respective owners.

Hayward is not in any way affiliated with or endorsed by those third parties.

For further information or consumer

technical support, visit our website at 

www.hayward.com

US: 908-355-7995

LIMITED WARRANTY (effective 03/01/12) Hayward warrants its OmniLogic, OmniPL, Pro Logic, OnCommand and E-Command 

pool automation products as well as its AquaRite, AquaRite Pro, AquaPlus and SwimPure chlorination products to be free of 

defects in materials and workmanship, under normal use and service, for a period of three (3) years.  Hayward also warrants 

its Aqua Trol chlorination products to be free of defects in materials and workmanship, under normal use and service for 

a period of one (1) year.  These warranties are applicable from the initial date of purchase on private residential swimming 

pools in the US and Canada.  Installations of product for use on commercial pools in the US and Canada is covered for a 

period of one (1) year for defects in materials and workmanship.  Hayward warrants all accessories and replacement parts 

for the above-identified pool automation and chlorination products for a period of one (1) year.  Accessories also include 

remotes, actuators, base stations, temperature sensors, flow switches and chemistry probes.  Each of these warranties is 

not transferable and applies only to the original owner.

Hayward shall not be responsible for cartage, removal, repair or installation labor or any other such costs incurred in 

obtaining warranty replacements or repair.

Proof of purchase is required for warranty service.  If written proof of purchase is not provided, the manufacturing date code 

will be the sole determinant of the date of installation of the product.  To obtain warranty service or repair, please contact 

the place of purchase or the nearest Hayward authorized warranty service center.  For more information on authorized 

service centers please contact the Hayward Technical Service Support Center (61 Whitecap Road, North Kingstown RI, 

02852) or visit the Hayward web site at www.hayward.com.

WARRANTY EXCLUSIONS:

1. Material supplied or workmanship performed by others in process of installation.

2. Damage resulting from improper installation including installation on pools larger than the product rating.

3. Problems resulting from failure to install, operate or maintain the product(s) in accordance with the recommendations 

contained in the owners manual(s).

4. Problems resulting from failure to maintain pool water chemistry in accordance with the recommendations in the 

owners manual(s).

5. Problems resulting from tampering, accident, abuse, negligence, unauthorized repairs or alternations, fire, flood, lightning, 

freezing, external water, degradation of natural stone used in or immediately adjacent to a pool or spa, war or acts of God.

6. Use of a non-genuine Hayward replacement salt chlorination cell on any Hayward automation or chlorination product 

will void the warranty for that product.

The express limited warranty above constitutes the entire warranty of Hayward Pool Products with respect to its products 

and is in lieu of all other warranties expressed or implied, including warranties of merchantability or fitness for a particular 

purpose. In no event shall Hayward Pool products be responsible for any consequential, special or incidental damages of 

any nature.   Some states do not allow a limitation on how long an implied warranty lasts, or the exclusion of incidental or 

consequential damages, so the above limitation may not apply to you.  This warranty gives you specific legal rights, and 

you may also have other rights, which vary from state to state.

Содержание AquaRite AQRS325OMNI

Страница 1: ...J 07922 Phone 908 355 7995 www hayward com Owner s Manual 092769 RevA Contents Before You Begin 2 Mounting the Equipment 7 Plumbing 8 Electrical 9 Preparing Water 17 Configuration 20 Operation 22 Remo...

Страница 2: ...ct failure Pursuant to the terms and conditions of any applicable Warranty the use of a non genuine Hayward replacement salt chlorination cell on any Hayward automation or chlorination product will vo...

Страница 3: ...e equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Industry Canada Statement This Class B...

Страница 4: ...5 VAC or 230 VAC connection from the main panel to AquaRite S3 Wire conduit for filter pump Wire for remote heater control Hayward Smart Relay required for single speed filter pump control Temperature...

Страница 5: ...ward Variable Speed VSP pump using the internal RS 485 connection a Pentair VSP using a Hayward HLPMPCONV converter sold separately or a single speed pump using a Hayward Smart Relay sold separately c...

Страница 6: ...he following pages 1 Mounting the equipment page 7 AquaRite S3 main unit Optional Temperature sensors 2 Plumbing page 8 TurboCell Flow Switch 3 Electrical Wiring page 9 High Voltage Low voltage wiring...

Страница 7: ...rectly from electrical panel Comm to VSP Power to Smart Relay wired in parallel with AquaRite S3 Comm to Smart Relay 15 To Single Speed Pump if no VSP is used Water Temperature Sensor Air Temperature...

Страница 8: ...used Select the proper mounting hardware given the size and weight of the unit The AquaRite S3 mounting brackets require a total of 4 mounting screws bolts to fasten the AquaRite S3 to the mounting s...

Страница 9: ...d 3 allow for chlorination of both the pool and spa during spa spillover operation but prevent overchlorination of the spa during spa only operation Never use configuration 4 Flow Switch IMPORTANT The...

Страница 10: ...ge channel inside the enclosure will ensure a separation of wiring and organize the low voltage wiring coming into the AquaRite S3 enclosure Refer to the diagram below for the location of knockouts an...

Страница 11: ...ning If not wired in that manner the flow switch will enable disable the chlorinator function Power Connection The AquaRite S3 can be powered by 115 VAC 2A or 230 1A VAC There is no need to manually...

Страница 12: ...will control the Smart Relay s function using the low voltage communication wiring The diagrams below show wiring for 115 VAC and 230 VAC Black White Gray Black Not Used Not Used Neutral Line 1 in Li...

Страница 13: ...ll control the pump s function using the low voltage communication wiring If the AquaRite S3 is NOT controlling the filter pump Use this wiring method when the AquaRite S3 is not controlling the pump...

Страница 14: ...Relay commu nication wires to their proper screw terminals then push the connector back onto the pins For best results strip back leads 1 8 before inserting into the screw terminals Hayward Variable...

Страница 15: ...nication cable Input Power Input Power bare wire Tristar VS 950 after Jan 2019 2 3 4 A B COM 1 2 3 4 3 2 COMBUS WALL MOUNT DISPLAY 1 2 3 4 5 6 7 8 CAUTION HIGH VOLTAGE M O T O R RED BLU BLK 4 Tristar...

Страница 16: ...see the heater manufacturer s recommendations on the minimum temperature rating for wires If no guidance is given use 105 C rated wire 3 Refer to the heater manual but it s very likely that the heater...

Страница 17: ...ous wiring completed locate the precut removable foam gasket that can be used to seal the low voltage exit Wrap it around the low voltage wiring at the exit of the enclosure shown below Work the gaske...

Страница 18: ...t swimmers may taste the presence of salt Saturation index The saturation index Si relates to the calcium and alkalinity in the water and is an indicator of the pool water balance Your water is proper...

Страница 19: ...is loss is due primarily to the addition of water because of splashing backwashing or draining because of rain Salt is not lost due to evaporation Type of Salt to Use It is important to use only sodiu...

Страница 20: ...or the first time be sure that the following items have been com pleted 1 Pool spa chemicals are within the recommended levels according to the table on page 17 2 Pool spa salt level is between 1200 P...

Страница 21: ...set values The functions of these buttons are shown below Use to increase a setting Use to decrease a setting Use to make a selection or to enter Main Menu Use to navigate Use to navigate Use to retur...

Страница 22: ...for recirculation freeze protection Firmware Upgrade The AquaRite S3 s firmware is the basic operating system that runs the unit The AquaRite S3 was shipped with the version of firmware that was avail...

Страница 23: ...Home Screen use the and buttons to adjust the desired chlorine level between 0 to 100 Heater Temperature Setting From the Home Screen use the UP and DOWN buttons to adjust the desired heater setpoint...

Страница 24: ...e to set the desired level lower For shorter run times increasing the level may be necessary After the initial level setting and run time you may need to raise the setting when the pool water temperat...

Страница 25: ...turn water temperature after the heater Instant PPM this is the salt concentration in the cell read at that moment Any changes to the pool s salt level will be seen instantly Average Salt this is the...

Страница 26: ...h Press the UP button to advance to the next schedule Set speeds on all desired schedules and then press OK To set the actual speeds for Low Medium and High settings refer to the Filter Pump section o...

Страница 27: ...pool cover detec tion as well as change pump speed and reduce chlorination when the cover is on the pool When the pool cover is closed chlorine is not lost to sunlight and bacteria load is typically r...

Страница 28: ...100 using the and but tons Press OK to save Sleep The AquaRite S3 can turn off its screen after a period of time if desired Use the and buttons to select the time interval then press OK If there are...

Страница 29: ...reeze protection by turning on the pump when the air tem perature drops below the freeze protection temperature which is set separately Low salt 1200ppm default when the salt level is lower than this...

Страница 30: ...on control or the Master AquaRite S3 Setting up remote operation requires a communication connection between the RS 485 connectors of the two devices Refer to the wiring diagrams below After this link...

Страница 31: ...at are connected to the AquaRite S3 will all be controlled by the Omni automation control To configure the Omni control to operate with the AquaRite S3 in Remote mode refer to the Configuration Wizard...

Страница 32: ...ded the manufacturing date code will be the sole determinant of the date of installation of the product To obtain warranty service or repair please contact the place of purchase or the nearest Hayward...