USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
11
If the AquaRite S3 is controlling a single speed filter pump using a Smart Relay
Use this wiring method when the AquaRite S3 is controlling a single speed filter pump with a Smart
Relay. The Smart Relay and the AquaRite S3 are continuously powered as shown. The AquaRite S3
will control the Smart Relay’s function using the low voltage communication wiring. The diagrams
below show wiring for 115 VAC and 230 VAC.
Black/W
hit
e
G
ray
Black
Not U
sed
Not U
sed
Neutral
Line 1 in
Line 1 out
Powering AquaRite S3 and
Smart Relay with 115 VAC
115 VAC Smart Relay
Black/W
hit
e
G
ray
Black
Red/W
hit
e
Red
Line 2 in
Line 1 in
Line 1 out
Line 2 out
Powering AquaRite S3 and
Smart Relay with 230 VAC
230 VAC Smart Relay
OR
115 VAC
Single Speed Pump
230 VAC
Single Speed Pump
Electrical Panel
Electrical Panel