7
Information Menu
The Information Menu displays valuable system and pool information. The AquaRite Pro will
default to displaying a portion of the Information Menu when no buttons have been pushed
for minutes. The unit will automatically scroll through several status displays. To access all
of the Information Menu items, push the INFO button on the front panel. Advance through
the various menu items using the "<" or ">" buttons. A list of the Information Menu items is
shown below.
The AquaRite Pro desired output % is shown here. If Super Chlorinate is
active, the display will show the time remaining until the AquaRite Pro will
return to the desired output %. This menu is disabled if an AQL-CHEM is
used and ORP Auto Sensing is enabled (see AQL-CHEM manual).
This display will be shown only if chemical sensing is enabled.
This display
shows both pH and ORP levels/status when chemistry sensing is enabled
via the Chemistry Configuration Wizard (requires the use of AQL-CHEM
Sensing Kit). The AquaRite Pro will refer to these levels to determine how
much chlorine to generate (ORP) and how much acid to dispense (pH). Refer
to the AQL-CHEM manual for specific information about these levels as well
as the recommended ranges.
+/- 3.45V is the voltage applied to the chlorinator cell
+/-6.75A is the current (amps) through the cell
9°C is the water temperature at the cell
3. g/L is the “instant” salt level at this time
For the chlorinator to be operating, several conditions must exist: the filter
pump must be running, the flow switch must be detecting flow, the chlorinator
setting must be set greater than 0%, the water temperature at the cell must
be between ºC and 60ºC, and the salt level must be within the operating
range. If any of these conditions are not met, the chlorinator diagnostic
display will tell you the reason. It’s possible to have more than one reason,
in which case after you rectify what was displayed the first time, a second
display will appear.
If the current (amps) display is 0.00A, then the chlorinator is operating
normally but is in the off part of its normal operating cycle. Simply press
either the “+” or “-“ key to start a new cycle.
If ORP Auto Sensing is not used
Chlorinator
50 %
No Function
Move to previous/next menu item
Super Chlorinate
22:15 remaining
No Function
Move to previous/next menu item
If AQL-CHEM is used
No Function
Move to previous/next menu item
pH 7.5
(On)
ORP 700 mV (On)
Press to switch chlorinator operation to opposite polarity (15 second delay)
Move to previous/next menu item
+23.45
+6.75A
29°C 3.2 g/L
Содержание AQUA RITE pro
Страница 155: ...www hayward fr HAYWARD AQL CHEM 50 Chemistry Kit...
Страница 159: ...4 M3 x x x x x 0 785 x x x 0 893 2 7 3 4 3 2 3 4 AquaRite Pro 3 5 4 0 NaCl 99 25 10 14 24 24 5 25...
Страница 168: ...12 Super Chlorinate AquaRite Pro Inspect Clean Cell 500 AquaRite Pro AquaRitePro AquaRite Pro 0 AquaRitePro 2...
Страница 169: ...13 2 1 1 AquaRite Pro AquaRite Pro AquaRite Pro 3 5 AquaRite Pro 230...
Страница 170: ...14 AQL CHEM AQL CHEM AquaRite Pro AquaRite Pro 50 63 50 63 1 13 1 2 3 4 2 30 15 1 2 4 3 30 cm 30 cm 30 cm...
Страница 171: ...15 2 3 14 AquaRite Pro 230 30 230 17 230 230 L AquaRite PRO...
Страница 172: ...16 AquaRite Pro AQL CHEMChemistryKit AQL CHEM AquaRite Pro AQL CHEM AQL CHEM...
Страница 173: ...17 pH GoldlineAQL CHEM pH 230 AQL CHEM pH AquaRite Pro pH pH 230 230 EP1 EP2 N L 230 pH...
Страница 176: ...20 Hayward AquaRite AquaRite Pro 1 Hayward 1 2 3 4 5 5 HAYWARD HAYWARD HAYWARD...
Страница 177: ...P I P A all e des Ch nes 01150 Saint Vulbas France HAYWARD...