background image

Pentair/Purex/MiniMax

1.  Turn power off to heater.
2.  Remove factory installed jumper from the “Ext Switch” connector.
3.  Wire the Aqua Plus to the “Ext Switch” connector as shown below.
4.  The wires to the Aqua Plus must be separated from any line voltage wires.  Failure to follow these instructions

may cause erratic operation of the heater.

5.  Set the Power (Thermostat Select) switch to either “Pool” or “Spa”.
6.  Set the “Pool” and “Spa” thermostats to their maximum settings.

MINIMAX

Ext.

Switch

Remove 

Factory Jumper

Raypak RP2100 Pool/Spa Heater

1.  Turn power off to heater.
2.  Push the mode button to “spa” mode.
3.  Set the temperature to the maximum.
4.  Push the mode button to “OFF”.
5.  Lastly, plug the prewired connector in the P7 position on the board.

!

 

 IMPORTANT:  The heater will display “OFF” when it is being remotely controlled by the Aqua Plus.

Some homeowners see the “OFF” display and, thinking this is a mistake, change the mode to “POOL” or

“SPA” which then disables the remote control by the Aqua Plus.  To prevent this:  Remove the heater touch

pad connector (P5) which will disable the touchpad.

P7

Light Blue

Black

Orange Stripe

Orange

Stripe

Black 

RAYPAK RP2100

Drawing is for digital
heater. If heater is a
millivolt (analog),
run red wires from
Fireman’s Switch
to heater relay.

15

STA-RITE Heater

1.  Turn power off to heater.
2.  Remove upper jacket and open the control box.
3.  Remove the jumper for the “fireman’s switch.
4.  Wire to the Aqua Plus using wire rated for 105°C minimum.

STA-RITE

Terminal

Board

Operating

‘Control

Fireman’s

Switch

Hayward Variable Speed Pump (VSP) Wiring and Address Setting

Refer to your TriStar or EcoStar manual(s) for proper low voltage communication wiring between the Aqua Plus and

the Hayward Variable Speed Pump.

A pump address must be configured for each VSP used in the system.  This address is entered into the VSP’s

configuration menu.  Refer to the table below to determine which address to use for your specific pump and Aqua Plus.

Select the proper address based on which output will be used and the model VSP you are configuring.

16

FILTER 

AUX1 

A

 

UX

LIGHTS 

Pro Logic Output

This is the output used to control the VSP.

Note that the VSP should be wired to this

output’s corresponding relay.

VSP Address

This is the name that should be selected

under “Set COMM bus address” (EcoStar)

or “*H.Comm ADDR.” (TriStar) within the

VSP’s Configuration Menu.

“001” - Tristar 

“Pool Filter” - EcoStar

“002” - Tristar 

”  -  EcoStar

Aux1 / Spa Filter

“Lights Button” - EcoStar only
 

Aux2 - EcoStar only

Содержание Aqua Plus PL-PLUS

Страница 1: ...Automation and Chlorination Installation Manual for model PL PLUS PL PLUS 20 Aqua Plus www hayward com...

Страница 2: ...al must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying the equipment One bonding...

Страница 3: ...trols 6 Optional Base Station 7 Optional ValveActuators 7 3 Plumbing Pool Spa Configuration 8 TurboCell 9 Flow Switch 9 4 Electrical Main Service 10 Wiring Grounding and Bonding 10 Circuit Breaker Ins...

Страница 4: ...remote AQL2 BASE RF required AQL2 SS RF Wireless Spa Side Remote Control AQ2L BASE RF required AQL2 BASE RF Base Receiver AQL DIM LightDimmerRelay GV A 24 ValveActuator V A xx Valve Actuator xx 1P 1 5...

Страница 5: ...ly if you are using the chlorinator features on theAqua Plus Control If you are NOT using the chlorinator it is recommended that you follow all of the other chemistry recommendations besides salt Refe...

Страница 6: ...0 67 100 133 136 181 114 152 23 30 45 60 32 80 36 90 41 100 45 110 160 50 73 120 170 55 77 130 180 59 81 140 190 64 86 150 200 68 90 93 42 107 48 120 55 133 61 147 213 67 98 160 227 73 104 173 240 79...

Страница 7: ...h x Average Depth x 893 Length x Width x Average Depth x 1000 POUNDS and Kg OF STABILIZER CYANURIC ACID NEEDED FOR 80 PPM Gallons and Liters of Pool Spa water Current Stabilizer Level ppm 0 ppm 20 ppm...

Страница 8: ...ose clamp over the sensor and gently tighten until O ring makes an adequate seal Do not overtighten 4 For maximum temperature accuracy cover the sensor and 3 6cm of pipe on either side with insulation...

Страница 9: ...seplate in the desired position screws supplied by installer 3 See ElectricalWiring page17 forinstructionsonrunningthecablefromtheAquaPlusmainunittothe remotedisplay keypad AQL SS 6B x x W or B for Wh...

Страница 10: ...be used in and around the pool spa area These units float and can be left in the water for easy access Optional Base Station TheAQL2 BASE RFoptionalbasestationmustbeinstalledifanywirelessremotecontro...

Страница 11: ...he systemisinthe poolonly operatingmode 6 The plumbing diagram above is intended to be used as a general guideline and is not a complete plumbing schematicforthepool 7 Theairsensormustbeinstalledifthe...

Страница 12: ...inguseadaptors providedbyinstaller Flow Switch TheflowswitchmustbeplumbedinthesamesectionofplumbingastheTurboCell Theflowswitchisasafetydevice thatensuresthatwaterisflowingthroughthecellbeforetheAquaP...

Страница 13: ...connected to the pool bonding system by an 8AWG 6AWG for Canada wire Alug for bonding 2 for Canada is provided on the outside bottom of theAqua Plus enclosure Circuit Breaker Installation and Wiring C...

Страница 14: ...s and the chlorinator This power should be connected to one of the circuit breakers WARNING 120VAC only permanent damage if connected to 240V High Voltage 120 240V Pool Equipment AllAqua Plus relays a...

Страница 15: ...proper input wiring to the VSP Wiring from the 220Vbreaker must connect through theAqua Plus s Filter Lights Aux relay Refer toVSPAddress Settingonpage16todeterminewhichrelayscanbeusedwithyourpump Th...

Страница 16: ...h 24V control circuits Refer to the diagram below for a generic connection The manuals supplied with most heaters alsoincludespecificwiringinstructionsforconnectingtheheatertoanexternalcontrol usually...

Страница 17: ...dthediagrambelow 1 Turn off power to heater 2 WireAqua Plus to terminals 1 2 see diagram 3 Leave jumper attached to terminals 4 5 4 Move BYPASS dipswitch on heater circuit board to ON position up 5 Tu...

Страница 18: ...r 1 Turn power off to heater 2 Push the mode button to spa mode 3 Set the temperature to the maximum 4 Push the mode button to OFF 5 Lastly plug the prewired connector in the P7 position on the board...

Страница 19: ...SP used in the system This address is entered into the VSP s configurationmenu RefertothetablebelowtodeterminewhichaddresstouseforyourspecificpumpandAquaPlus Select the proper address based on which o...

Страница 20: ...typically phone cable to connect the wired remote display keypad with theAqua Plus ControlCenterasshownbelow Themaximumwiringdistanceis500ft 160m Notethattheterminalsonboththe AquaPlusmainunitandthewi...

Страница 21: ...Aqua Plus control unit as shown below Connector for AQL CHEM Flow Switch Only applicable if the chlorinator function is enabled The flow switch cable plugs into theAqua Plus ControlCenteratthepositio...

Страница 22: ...rinators when additional sanitizing capacity is re quired A4 wire connection is used to communicate to theAqua Rite and can be wired up to 500 apart Any outdoor rated 4 conductor cable can be used Ref...

Страница 23: ...e to next configuration menu Push to access Chlorinator option Cell Type T CELL 15 Chlorinator Enabled Display Salt Chlor Config to view change Chlorinator TheAqua Plus is shipped with the chlorinator...

Страница 24: ...s It is programmed in increments of 5 minutes from Manual On Off 0 minutes to 21 00 21 hours The filter is forced on during this time period Spa Spillover When spa spillover is Enabled and Pool and Sp...

Страница 25: ...variable speed pump The Filter relay is used to supply input power to the pump The relay will be on when the filter pump output is on When the filter pump output is off the relay will be off On off an...

Страница 26: ...ng The desired temperature is in the Settings Menu If applicable the homeowner will be prompted to enter separate pool and spa settings Depending on the position of the pool spa suction valves the pro...

Страница 27: ...d temperature is in the Settings Menu If applicable the homeowner will be prompted to enter separate pool and spa desired temperature settings Depending on the position of the pool spa suction valve t...

Страница 28: ...ts are used the lights relay can be used to control other pool devices that may require these options The function of each option is shown below Manual On Off default the lights relay will alternate b...

Страница 29: ...ction is Settings Menu This is the speed of the pump that has been selected in the Settings Menu for normal filter operation If an alternate speed is desired when the Lights output is on push or and s...

Страница 30: ...elay will be on when theAux output is on and off when the output is off On off and speed are controlled by commands sent to the VSP Aux1 Interlock If Enabled this feature will override the function Ma...

Страница 31: ...ch clock hour and then switch to the jets skimming for the last half of the hour Super Chlorinate if Chlorinator is enabled this option allows the user to start a Super Chlorinate cycle when the Valve...

Страница 32: ...ly show the default menu and allow on off control via the pushbuttons Note that the function of the Aqua Plus s built in display keypad is unchanged by this selection Once disabled the only way to ena...

Страница 33: ...d phenol test kit Clean Probe Wizard to enter Push to access Clean Probe Wizard Move to previous next menu item Use this Wizard to clean theAQL CHEM s ORPand pH probes The probes must be clean and fre...

Страница 34: ...lly 104 F 40 C Also note that some heat pumps actually have be set to the lowest possible temperature 3 Oncetheheaterisrunning youcanverifythe heatercooldown feature optional seeConfigurationMenu Heat...

Страница 35: ...service center For more information on authorized service centers please contact the Hayward Technical Service Support Center 61 Whitecap Road North Kingstown RI 02852 or visit the Hayward web site a...

Страница 36: ...t beeper teach wireless remote wireless channel maintenance menu pH calibration wizard clean probe wizard timers menu pool filter 1 or hi speed 1 pool filter 2 or lo speed 1 pool filter 3 or hi speed...

Отзывы: