2.SPECIFICATION
2.1 Performance data of Swimming Pool Heat Pump Unit
REFRIGERANT : R410A
Unit
Model
P HCP 5 0 A
P HCP 6 5 A
Heating Capacity
kW
11 . 1 9
14.7
Heating Power Input
kW
1. 87
2.68
Running Current
A
8. 22
12
Power Supply
208-230V~/ 60Hz
208-230V~/ 60Hz
Compressor Quantity
1
1
Compressor
ro t a ry
rotary
Fan Quantity
W
1
1
Fan Power Input
RP M
120
120
Fan Rotate Speed
850
850
Fan Direction
horizont al
horizont al
Noise
dB (A )
54
54
Water Connection
mm
48.3
48.3
Water Flow Volume
m
3
/ h
4.0
4.5
Water Pressure Drop(max)
kP a
12
10
Unit Net Dimensions(L/W/H)
mm
Se e t h e d ra win g o f t h e u n it s
Unit Shipping Dimensions(L/W/H)
mm
Se e package label
Net Weight
kg
Se e nameplat e
Shipping Weight
kg
Se e package label
Heating: Outdoor air temp:27
℃
/24
℃
, Inlet water temp:26
℃
2