background image

Pole Track © 2003, Hayton Systems

Page  20

8.3

Add, Edit, Delete Attachments

The      

Attachments     section  allows  you  to

maintain  a  list  of  attachments  for  each  pole.

You can add a new attachment, edit  an existing

attachment, or delete an attachment.

Tap the     

Attachmnts     field  to  display  the  list  of

attachments for the current pole.

Attachments List

This screen  shows  the  list  of  attachments
for the current pole. Tap 

  to  return

to the data entry screen.

Add or Edit an Attachment

Tap 

  to  create a  new  attachment,  or

  to  edit  an  existing  attachment.  Most

data fields use MRU (     

M

     ost      

R

    ecently     

U

    sed)

lists to make data entry  faster,  easier,  and

more accurate.

Tap 

 to store the  data and return to  the

Attachments    (list) screen.

Delete an Attachment

Select the attachment  to  delete  and  press 

.  Pole  Track  displays  a

warning prompt before deleting the attachment.

!! Note !!  

The      

Company     field uses MRU lists that change depending on the

Ownership

     field selected. If you select 

 you get an MRU list unique to Verizon. If

you select 

 then you get an MRU list unique to power companies.

Содержание HPK012

Страница 1: ...7 2 2003 Pole Track User s Manual HPK012 Contractor Kit...

Страница 2: ......

Страница 3: ...WA 98223 360 659 5804 fax 360 659 6823 800 990 8360 www haytonsystems com Verizon Approved by Dennis Brooks dennis brooks verizon com 972 718 6150 This document contains Hayton Systems Confidential an...

Страница 4: ...DATE AND TIME 14 6 APPLICATION LAUNCHER AND RESTORER 15 7 START POLE TRACK AND ENTER SETTINGS 16 7 1 Maintaining the List of Auditors 17 8 TRACKING POLE ASSETS 18 8 1 DATA View 18 8 2 Data View Fields...

Страница 5: ...Palm III operating system Pole Track terminals include some standard Palm III organizer functions an integrated bar code scanner and a GPS module GPS Module The GPS Global Positioning System module p...

Страница 6: ...Cradle Cradle Power Supply Power Supply Cord Vehicle Charging Adapter Spare Battery Stylus 5 Pack with slip case with cable for cradle Lithium Ion H15019 H15004 H15008 H15009 H15017 H15016 H15013 GPS...

Страница 7: ...bol SPT1800 with 1D Scanner H15004 Modem Cradle with cable H15025 GPS Adapter H15008 Cradle Power Supply H15009 Power Supply Cord for Cradle H15016 Spare Battery Lithium Ion H15013 Stylus 5 Pack H1501...

Страница 8: ...repair process Complete and submit the online Return Authorization RA Form After submitting the RA you will receive an RA number via email Print two copies of the authorization one copy for your recor...

Страница 9: ...Pole Track 2003 Hayton Systems Page 5 Arlington WA 98223...

Страница 10: ...e battery is charging and green means it is fully charged 4 Remove the terminal from the yellow Soft Case Do not place the terminal in the Modem Cradle yet Press the red button on the terminal to turn...

Страница 11: ...launch ATS Register If it does launch it tap to go back to the Application Launcher 16 At the Application Launcher find the ATSync icon use the vertical scroll bar on the screen if necessary and tap...

Страница 12: ...tach the GPS module to the bottom of the Pole Track terminal and use the GPS Check application to initialize the GPS module Note initializing the GPS unit for the first time can take up to eight minut...

Страница 13: ...screen 4 Press the DATA button to move to the main Pole Track data collection screen 5 Enter the pole data into the main detail screen Tap the initials top line or the summary line second line to acti...

Страница 14: ...s unique to Pole Track DATA view is the main data input and edit screen GRID view acts as a quick reference to view the most pertinent record data HELP view displays additional operating information U...

Страница 15: ...ou all three work the same way Scroll Buttons The two scroll buttons allow you to scroll through lists data entry fields and sometimes between screens Use the button most convenient for you both work...

Страница 16: ...te with the terminal Many third party applications exist for Palm terminals We highly recommend not using these applications in your terminal These applications could have a detrimental effect on Pole...

Страница 17: ...a characters using the pop up keypad Tap abc or 123 on the writing pad to activate the keypad The custom keypad looks like this The custom keypad allows you to scroll through the current set of data f...

Страница 18: ...djust the time values using the up down arrows Select the portion of the time to adjust and use the arrow keys to adjust the value Press to set the time Set Date Select today s date be sure to set sel...

Страница 19: ...te downloading the latest version of the P o l e T r a c k application The terminal dials the server and receives the current Pole Track version Tap the PoleTrack icon to start the application To load...

Страница 20: ...sure to verify these settings each time you use the terminal Tap the initials on the top line of any Pole Track screen to access the Settings Tap after entering all Settings data Select the appropriat...

Страница 21: ...to maintain the list of auditors You can add a new auditor edit an existing auditor or delete an auditor When you are finished tap to return to the Settings screen Delete an Auditor Select the name t...

Страница 22: ...tom of the terminal to access the DATA and GRID views 8 1 DATA View In DATA view you can enter or edit records DATA view shows all data fields for each record The number and type of data fields varies...

Страница 23: ...nt value to display the attachment list for this Pole record see Attachments section for details Owner These radio buttons allow you to select a single owner for this pole record Anchors Tap this summ...

Страница 24: ...e data entry screen Add or Edit an Attachment Tap to create a new attachment or to edit an existing attachment Most data fields use MRU Most Recently Used lists to make data entry faster easier and mo...

Страница 25: ...each record line Tap this button to delete all marked records You can also use the pull down list in GRID view to mark and unmark records Pole Track prompts you for a conformation prior to deleting a...

Страница 26: ...ect the field type that you want to update enter the current value to change enter the new field value and tap Caution This function could cause unwanted changes if you don t verify the change request...

Страница 27: ...heck shows how many satellites it can receive and the number of satellites that are usable once the cold start is complete For example it may display Usable Satellites 4 9 This indicates that the adap...

Страница 28: ...24 Appendix A Graffiti A 0 Space B 1 Backspace C 2 Return D 3 Caps Shift E 4 Caps Lock F 5 Menu Cmd G 6 Cursor Left H 7 Cursor Right I 8 Short Cut J 9 Space K Tap Once to use the shifted characters L...

Страница 29: ...ad from the GPS module Hgt Numeric Height in feet and inches This field must be in F FF or FFII formats where F F f e e t 0 99 II inches 0 11 defaults to 0 N Numeric These fields contain only the digi...

Страница 30: ...e Date 4 4 4 4 Default to the data entry date for this pole Audit Vendor A N 1 40 1 40 Name of the vendor company performing the audit Auditor Name A list 1 40 1 40 Name of the individual performing t...

Страница 31: ...3 4 5 6 7 8 9 10 Pole Type Treatment N 1 1 1 1 Part of the Birthmark brand Enter a best guess if not on the birthmark brand Required for new poles 1 Creosoate SPC 2 Penta SPP 3 Copper Arsenate CCA 4...

Страница 32: ...attachment Guy Guying Required Y N 1 1 1 1 Defaults to N NO guy is not required YES guys are missing or required Trim Tree Trim Y N 1 1 1 1 Defaults to N YES trim trimming is required Tag VZ Pole Tag...

Страница 33: ...D 15 0F SI 58 3A 101 65 E 16 10 DLE 59 3B 102 66 F 17 11 DC1 60 3C 103 67 G 18 12 DC2 61 3D 104 68 H 19 13 DC3 62 3E 105 69 I 20 14 DC4 63 3F 106 6A J 21 15 NAK 64 40 107 6B K 22 16 SYN 65 41 A 108 6C...

Страница 34: ...Pole Track 2003 Hayton Systems Page 30 41 29 84 54 T 127 7F 42 2A 85 55 U 128 80...

Страница 35: ...ions so the touch screen can accurately know the stylus position When calibrating the digitizer touch the stylus to the center of the bull s eye marker when prompted Category The Palm terminal allows...

Страница 36: ...actions to be taken that relates to an attachment The indicators are Guying Required Trimming Tag and Dual Pole Keypad Pole Track includes a custom keypad that you can use to enter data Tap the calcul...

Страница 37: ...Synchronization is the process of integrating data between two systems normally a Palm terminal and a PC You might enter new address on your PC and enter appointments on your Palm terminal During sync...

Отзывы: