HY-1080 Digital Microscope Camera

Содержание HY-1080

Страница 1: ...HAYEAR HY 1080 Digital Microscope Camera...

Страница 2: ...80 3 Main Device 3 Remote Control 4 Connection and Output 5 Direction 6 Individual Use 6 HDMI Output 15 USB Output 16 Software Installation 16 Software Operation 19 Icon Definition 19 Interface Defini...

Страница 3: ...vant laws and regulations In order to provide our guest with a better customer experience the product may have minor change during perfecting the description in this instruction is only for reference...

Страница 4: ...the pulley and stand column to fix the focus How to increase the lens magnification Standard working with 150x lens 2x attachment objective lens HY 108 Standard working with 150x lens if you add a 2x...

Страница 5: ...0 Lock unlock lock the file when recording to avoid delete by mistake Sharpness sharpness there are three sharpness high medium and low two buttons can switch the sharpness but the sequence is differe...

Страница 6: ...pe Base double lamp power supply USB DC in provide power to microscope and LED light LED light adjustment control the brightness of the light turn on off button menu button button down button up confi...

Страница 7: ...h the mode also you can press on the remote control MODE button 2 definition of the image under different mode video standby mode capture mode video mode image playback mode video playback mode when t...

Страница 8: ...press on the or the button to set the image size you need Quality setting Under the capture mode press on the MENU button to enter the main menu press on the button till the quality setting highlight...

Страница 9: ...ng highlight then press OK button to enter and then press on the or the button to select NTSC or PAL mode White balance setting Press on the MENU button to enter the main menu press on the button till...

Страница 10: ...ess on the OK button to enter when the option is blue you can press on the or the button to set after finishing an option press on the OK button to save and then set the other option after finishing a...

Страница 11: ...option highlight then press on the OK button to enter and then press on the or the button to select cancel or OK option when select cancel and press on the OK button then it will return to main menu...

Страница 12: ...the or the button to select open or close Date label setting Under the video mode press on the MENU button to enter the main menu press on the button till Date label setting option highlight then pre...

Страница 13: ...set Capture three ways 1 Short press on the M button to enter the capture mode click OK to take photos 2 Just press on capture button 3 When use the remote control press on the capture button Video re...

Страница 14: ...he WIFI function through remote control WIFI function can be only open by remote control then it will display the account and password the account is HY 1080d9eea30d21c0 password 12345678 Second step...

Страница 15: ...f can not work under the HDMI output Under the HDMI output the microscope can take picture but can not record video FAQ 1 Why these is no image on the monitor Check if all the lines connected properly...

Страница 16: ...ebar tab Switching the rightmost control panels currently provides camera control and measurement functions 3 Control panel Specific camera control and measurement operations 4 Status bar Display came...

Страница 17: ...e If the connected camera can not support some functions such as brightness target value then the corresponding parameter can not be set up Red Green and Blue gain If the connected camera can not supp...

Страница 18: ...nter point and radius Two Points Circle Measure a circle the circle is determined by two points Three Points Circle Measure a circle the circle is determined by three points Arc Measure length of arc...

Страница 19: ...catior Actual Length Meter 4 After select calibration choose the unit and multiplying power you need then you can calibrate How to set cross hair on measure software 1 First step select setup 2 Second...

Страница 20: ...the system there are Microsoft Net Framework 4 0 and Microsoft Visual C 2010 Runtimes 2 The software works fine but the software can not recognize the microscope First please make sure that you connec...

Страница 21: ...e Address Phone number Post code email Model name Purchase date Fault feedback Date Fault Notice Our warranty doesn t cover 1 If users can not provide the purchase proof or the Warranty 2 If users use...

Страница 22: ...Copyright HAYEAR...