SUPPLY STOP &
3/8" O.D. TUBING
(NOT SUPPLIED)
1-1/4" IPS TRAPS (NOT SUPPLIED)
WASTE BENDS
33-11/16"
SUPPLY
856mm
FOUNTAIN
1. HOLD ROUGH-IN DIMENSIONS ±1/8" (3.2mm).
2. WHEN INSTALLING THIS UNIT, LOCAL, STATE, OR FEDERAL CODES SHOULD
BE ADHERED T0. FOR INSTALLATION DIMENSIONS (LOCATIONS), WASTE AND
SUPPLY REQUIREMENTS OTHER THAN SHOWN, DIMENSIONS MARKED (*)
MUST BE ADJUSTED ACCORDINGLY.
3 ALIGN HOLES IN CHILLER SUPPORT TRAY WITH HOLES IN FRAME
AND FASTEN WITH #10 SHEETMETAL SCREWS.
4 REFER TO 5874 SERIES OPERATION AND MAINTENANCE MANUAL FOR
PUSH BUTTON AND VALVE INSTALLATION/MAINTENANCE INSTRUCTIONS.
5 REFER TO MTGFR.LG INSTALLATION DRAWING FOR ROUGH-IN DIMENSIONS.
6 INSERT 5/16"-18 PANEL INSERTS FROM OPPOSITE SIDE AT LOCATIONS
SHOWN BY DARKENED HOLES. HOLE COMBINATIONS SHOWN ARE FOR USE
WITH LOW FOUNTAIN ON THE RIGHT AND HI FOUNTAIN ON THE LEFT.
USE OPPOSITE HOLES FOR HI ON RIGHT AND LOW ON LEFT.
7 HOLE COMBINATION SHOWN BELOW IS FOR USE WITH LOW
FOUNTAIN ON THE RIGHT AND HIGH FOUNTAIN ON THE LEFT.
USE OPPOSITE HOLES FOR HIGH ON RIGHT AND LOW ON LEFT.
8 TO CHANGE FOUNTAIN MTG. SCREW LOCATIONS: FIRST REMOVE
SCREWS AND THEN SQUEEZE CLIPS ON NUT RETAINER TO POP
OUT. SNAP INTO NEW POSITIONS AND RE-ASSEMBLE SCREWS.
9. IMPORTANT: A L.H. LOW (OPTIONAL) CONFIGURATION WILL REQUIRE
A DIFFERENT BACK PANEL AND THE WASTE AND SUPPLY
DIMENSIONS SHOWN (*) MUST BE REVERSED.
10 REFER TO 1RKHO.H & 2RKHO.H OPERATION AND MAINTENANCE
INSTRUCTIONS FOR TRANSFORMER AND SENSOR SETUP.
*
LOCATE AND INSTALL
SENSOR
EYE
HCR8
ELECTRICAL TRANSFORMER
MOUNTING
(SUPPLIED)
(38mm)
(1-1/2")
CLIP
(SUPPLIED)
GRILLE
PANEL
(SUPPLIED)
BACK
Ø
2X
31 1/8"
5/8"
16mm
4
2X
791mm
ROUGH-IN
813mm
32"
14-1/8"
359mm
WASTE
9VDC SOLENOID VALVE
57mm
2 1/4"
686mm
864mm
34 5/32"
*
LINE
*
27"
FLOOR
CHILLER SUPPORT TRAY
5
5
3
ELECTRICAL
ACCESS
28-11/16"
729mm
FOUNTAIN
*
5
SUPPLY
101.6mm
MOUNTING FRAME
(SUPPLIED)
WASTE BEND
1-1/4" O.D.
MTGFR.LG
991mm
956mm
37 5/8"
ROUGH-IN
*
*
997mm
39-1/4"
39 5/32"
*
812mm
32"
*
13mm
1/2"
76mm
3"
FOUNTAIN
27-7/8"
708mm
835mm
32-7/8"
FOUNTAIN
WASTE
*
(NOT SUPPLIED)
MOUNTING
CLEARANCE
WIDTH
473mm
18-5/8"
4"
FRAME
305mm
12"
FACE
WALL
BACK
PANEL
FLANGE
FRAME
406mm
16"
BOWL MOUNTING PATTERN DETAIL
6 8
SCREW 8
7
NOTES:
2X SHEET METAL
2X MOUNTING CLIP
INSIDE OF FRAME
(SUPPLIED)
SCREW
FRAME
MOUNTING
SCREW
(SUPPLIED)
2X MACHINE
*
GRILL
(SUPPLIED)
FRAME FLANGE BUTTS AGAINST
MUST BE INSTALLED SO THAT
IMPORTANT: MOUNTING FRAME
FINISHED WALL FACE.
REGULATOR
APPROVED:
DRAWN:
PART NUMBER
SCALE:
SHEET
OF
REVISION
DRAWING TYPE:
SIZE: A
BY:
ECN NO.
PA
GE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
PAGE
Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
RTM
07/97
28
0002080250.D
H1011.8HO/H1011.8HO2
NA
1
2
BJM
05/13/21
.
FV
9 OF
10
INSTALLATION
5688
9 O
F
10
2021
DP
REQUIRED -
SOLD SEPARATELY
MODEL H1011.8HO SHOWN
MODEL H1011.8HO2 ON SHEET 2
10
100-277VAC-9VDC
TRANSFORMER
AND DC CABLE
(SUPPLIED)
FROM DIRECT
CONTACT WITH WATER
WITHIN WALL
(ROUGH-IN DIMENSIONS APPLY TO BOTH MODELS WITH EXCEPTION NOTED ON SHEET 2)
MUST BE PROTECTED
10
10
CHILLER
REQUIRED -
SOLD
SEPARATELY
SENSOR
FROM CHILLER OUTLET
TO
BUBBLER
HEAD
-Vo
+Vo
AC(L)
AC(N)
BLACK WIRE
WHITE WIRE
TRANSFORMER
SENSOR WIRING / SUPPLY PLUMBING
SCHEMATIC
TO PUSH
BUTTON
FOUNTAIN
VALVE
SOLENOID
VALVE
PRESSURE
REGULATOR
CONNECT 3/8" PUSH-TO-CONNECT TEE TO
3/8" X 1/4" REDUCER THEN TO 1/4" DIAMETER
OUTLET TUBE ON HCR8 WATER CHILLER