background image

05/21 

      MODEL H1011.8HO/H1011.8HO2 

PAGE 4 OF 10 

 

 

INSTALLATION PROCEDURE…

 

 
STEP 4: 

Remove 1-

1/2” IPS outlet elbow from traps (not supplied). Install elbow inside frame 

onto waste stub-outs. 

Reassemble trap “U” bends with inlets centered behind 

fountains.  

 

STEP 5: 

Remove slip joint nuts from bottom of fountain waste outlet.  Assemble nut over 1-
1/4” O.D.  end of waste elbow as supplied by Haws.  Assemble waste elbow onto 
bowl waste body using seal washer provided and tighten nut hand tight.  Measure 
vertical distance down to trap inlet and cut the vertical (not supplied) elbow to length 
allowing 1/2" minimum for engagement into trap.  Mark and similarly cut to length the 
horizontal waste elbow.  Install elbow and tighten all the slip joint nuts. 

 

STEP 6:    

See Figure 1 (below) for detail section view of side screw grille attachment. Unpack 
grille and insert upper lip behind bottom of back panel, align sides and hold up flush 
to bottom of back panel. Hold grille against wall and mark centers of grille side slots 
on wall. Masking tape may be used to prevent finished wall damage from mark. 
Install the “s” clips in mounting frame using #10 sheet metal screws into pre-drilled 
holes on lower end of each side of frame. Tighten #10 screw w

hile holding “s” clips 

centered on wall marks. Check grille fit by installing grille and partially tightening #6-
23 socket head screws through side of grille. Ensure proper panel and grille 
alignment, then tighten eight 5/16-18x1 hex head screws. 

STEP 7: 

Unpack and remove chiller from carton. Remove front panel screws and panel.  Do 
not remove insulating putty and foam from copper tubes or Styrofoam insulation from 
evaporator coil. Remove any inner packing, which may be around compressor.  If 
applicable, remove junction box cover and electrical knock out on lower right side of 
housing.  Install fittings (supplied) on chiller inlet and outlet tubes (see Installation 
Drawing). 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 

FIGURE 1 

# 10 SHEET

METAL SCREW

“S” CLIP

MOUNTING
FRAME

STUD

# 6 SCREW

FINISHED
WALL

GRILLE

CLIP NUT

 

Содержание H1011.8HO

Страница 1: ...th made by the owner or his agents except upon written authority from HAWS Sparks Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that HAWS shall not be liable for general special or consequential damages claimed to arise under the contract of sale The drinking fountain manufactured by HAWS is w...

Страница 2: ...4 7 AMPS Chiller wired direct to incoming line by others Sensor s H1011 8HO with 1RKHO H 100 277VAC x 9VDC 50 60Hz 5 Watts H1011 8HO2 with 2RKHO H 100 277VAC x 9VDC 50 60Hz 5 Watts MAINTENANCE Periodically clean strainers One is inside push button valve on Model H1011 8HO refer to 5874 Series Valve Manual for details other is on inlet side of chiller PARTS LIST MODEL PACKAGE QUANTITY ITEMS INCLUDE...

Страница 3: ... depress collet and pull tubing out Tube Sizes O D Tolerance Insertion Depth 1 4 005 11 16 3 8 005 3 4 1 2 005 7 8 STEP 1 Provide wall opening as detailed in installation Drawing Frame must be positioned such that frame flanges overlap and butt against finished wall surface Mounting holes are provided for 6 sheet metal screws After frame is positioned in wall swing chiller support tray into positi...

Страница 4: ... and hold up flush to bottom of back panel Hold grille against wall and mark centers of grille side slots on wall Masking tape may be used to prevent finished wall damage from mark Install the s clips in mounting frame using 10 sheet metal screws into pre drilled holes on lower end of each side of frame Tighten 10 screw while holding s clips centered on wall marks Check grille fit by installing gr...

Страница 5: ...tment Model H1011 8HO H1011 8HO2 5867 Valve Pressure Regulator Adjust bubbler stream height using the black pressure regulator mounted inside bracket that has Hands Off HO sensor unit by loosening the locknut and rotating the knob clockwise to increase flow or counterclockwise to reduce flow Tighten the locknut and check flow height Repeat these steps until the bubbler flow height is correct STEP ...

Страница 6: ...ve Manual d Adjust valve to increase flow Use front adjust screw or see 5874 Series Valve Manual e Clean screens inside nozzle body Unscrew nozzle insert and very gently activate water supply to pop out qty 3 screens be careful not to lose screens Remove any debris clogging the screen openings and place back into nozzle body Reassemble nozzle insert 2 Water too warm or cold a Adjust chiller temper...

Страница 7: ...ty of Haws Corporation C R MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM ITEM DESCRIPTION THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER PART NO RTM 10 21 98 28 00020...

Страница 8: ...EL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM ITEM DESCRIPTION THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER PART NO FV 07 22 20 28 0002080250 H1011 8HO H1011 8HO2 NA 2...

Страница 9: ...UPPORT TRAY 5 5 3 ELECTRICAL ACCESS 28 11 16 729mm FOUNTAIN 5 SUPPLY 101 6mm MOUNTING FRAME SUPPLIED WASTE BEND 1 1 4 O D MTGFR LG 991mm 956mm 37 5 8 ROUGH IN 997mm 39 1 4 39 5 32 812mm 32 13mm 1 2 76mm 3 FOUNTAIN 27 7 8 708mm 835mm 32 7 8 FOUNTAIN WASTE NOT SUPPLIED MOUNTING CLEARANCE WIDTH 473mm 18 5 8 4 FRAME 305mm 12 FACE WALL BACK PANEL FLANGE FRAME 406mm 16 BOWL MOUNTING PATTERN DETAIL 6 8 S...

Страница 10: ... 07 22 20 28 0002080250 D H1011 8HO H1011 8HO2 NA 2 2 BJM 05 13 21 FV 10 OF 10 INSTALLATION 5688 10 OF 10 2021 DP SENSOR EYE 10 10 LOCATE AND INSTALL ELECTRICAL TRANSFORMER WITHIN WALL ELECTRICAL ACCESS H1011 8HO2 MODEL 100 277VAC 9VDC TRANSFORMER AND DC CABLE SUPPLIED FROM DIRECT CONTACT WITH WATER MUST BE PROTECTED 10 10 MODEL H1011 8HO2 SHOWN MODEL H1011 8HO ON SHEET 1 SEE SHEET 1 FOR APPLICABL...

Отзывы: