No. 0002080246 (20) 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

 
 
 
 

 

Model H1001.8/H1001.8HPS  

Water Cooler 

 

INSTALLATION, OPERATION 

MAINTENANCE INSTRUCTIONS 

 

LIMITED WARRANTY

 

 

HAWS warrants that this specific product is guaranteed against defective material or 
poor workmanship for a period of 

one year from date of shipment. 

HAWS liability 

under this warranty shall be discharged by furnishing without charge F.O.B. HAWS 
Factory  any  goods,  or  part  thereof,  which  shall  appear  to  the  Company  upon 
inspection to be of defective material or not of first class workmanship, provided that 
claim  is  made  in  writing  to  Haws  within    a  reasonable  period  after  receipt  of  the 
product.  Where  claims  for  defects  are  made,  the  defective  part  or  parts  shall  be 
delivered  to  the  Company,  prepaid,  for  inspection.  HAWS  will  not  be  liable  for  the 
cost of repairs, alterations or replacements, or for any expense connected therewith 
made  by  the  owner  or  his  agents,  except  upon  written  authority  from  HAWS, 
Sparks,  Nevada.  HAWS  will  not  be  liable  for  any  damages  caused  by  defective 
materials or poor workmanship, except for replacements, as provided above. Buyer 
agrees that HAWS shall not be liable for general, special, or consequential damages 
claimed  to arise  under  the  contract  of  sale. The  drinking  fountain manufactured  by 
HAWS is warranted to function if installation and maintenance instructions provided 
are  adhered  to.  The  units  also  must  be  used  for  the  purpose  for  which  they  were 
intended. 
 

NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, 
PROVIDED OR GIVEN BY HAWS.

 

 

CAUTION!

 Prior to making any electrical connections, verify with a voltmeter that power from the 

service panel is 

off.

 

NOTE TO INSTALLER: Please leave this information with the Maintenance Department. 
 
Haws electric water cooler’s are not designed or recommended for outdoor or corrosive 
environments such as enclosed chlorinated pool areas. 
Consideration must be made at the time of installation to adhere to state and/or local codes and 
environmental/atmospheric conditions such as, but not limited to, dust, corrosion, freezing etc. 
These conditions will void the warranty. 

Содержание H1001.8

Страница 1: ...made by the owner or his agents except upon written authority from HAWS Sparks Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that HAWS shall not be liable for general special or consequential damages claimed to arise under the contract of sale The drinking fountain manufactured by HAWS is warr...

Страница 2: ...ATM flowing pressure Where sediment or mineral content is a problem an inlet filter is recommended PLUMBING CONNECTIONS Inlet is 3 8 O D tube Waste outlet is 1 1 4 O D tube ELECTRICAL CONNECTIONS 115VAC 60HZ 4 7 AMPS Chiller wired direct to incoming line by others PARTS LIST MODEL PACKAGE QUANTITY ITEMS INCLUDED MTGFR SM 1 Mounting Frame Required Sold Separately 3 10 Sheet Metal Screws HCR8 1 Chil...

Страница 3: ...11 16 3 8 005 3 4 1 2 005 7 8 STEP 1 Provide wall opening as detailed in Installation Drawing Frame must be positioned such that frame flanges overlap and butt against finished wall surface Mounting holes are provided for 6 sheet metal screws After frame is positioned in wall swing chiller support tray into position See Installation Drawing align tray holes with holes in frame and fasten with 10 s...

Страница 4: ...all fittings supplied on chiller inlet and outlet tubes See Installation Drawing STEP 8 Thoroughly flush supply line to remove all foreign matter Connect 1 2 IPS supply screwdriver stop not supplied to stub out in wall Place chiller on chiller support tray against right hand side fully to rear with condenser open panel side facing to front Install supply 3 8 O D tubing not supplied between screwdr...

Страница 5: ...trol After adjustment allow unit to cycle off before checking outlet water temperature TROUBLESHOOTING PROBLEM REPAIR CHECKLIST 1 Insufficient bubbler flow 1a Check that inlet screwdriver stop valve is in wide open position b Verify minimum 30 psi flowing supply pressure c Clean strainer See 5874 Series Valve Manual d Adjust valve to increase flow Use front adjust screw or see 5874 Series Valve Ma...

Страница 6: ...s Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation C R MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE W...

Страница 7: ...NTENANCE MANUAL FOR PUSH BUTTON AND VALVE INSTALLATION MAINTENANCE INSTRUCTIONS 5 REFER TO MTGFR SM INSTALLATION DRAWING FOR ROUGH IN DIMENSIONS 6 INSERT 5 16 18 PANEL INSERTS FROM OPPOSITE SIDE AT LOCATIONS SHOWN BY DARKENED HOLES 7 FOUNTAIN REMOVAL FIRST REMOVE SCREWS AND THEN SQUEEZE CLIPS ON NUT RETAINER TO POP OUT INSTALL IS REVERSE OF REMOVAL 8 ALIGN HOLES IN CHILLER SUPPORT TRAY WITH HOLES ...

Отзывы: