The troubleshooting suggestions marked with a * may be carried out only by the manufacturer
or an authorised service partner appointed by the manufacturer.
4.3
Alarm functions and error displays
Alarm functions
Batch counter, set
with counting direction
downwards, has reached
the value 0
Cancelling the alarm
Set batch counter to a value > 0
or
set the counting direction of the batch
counter to up
See page 19
Error displays
Sealing temperature outside
Tolerance
Possible cause
Remedy
Temperature sensor defective
Controller defective
SST module faulty
Replace temperature sensor*
Replace controller*
Replace SST module*
Flashes
Flashes
Lights up