Troubleshooting checklist
Malfunction
Possible cause
Remedy
The sealing device does
not switch on
No data on the display
Mains connection power cable
not plugged in
-Power cable defective
Fuse
Temperature controller faulty
Check the mains connection and,
if necessary, plug into a different
power outlet
Replace power cable
Replace the fuse*
!
If the fuse blows again,
it is imperative to have
the sealing device tested
Replace temperature controller*
The sealing device does
not heat up
Set temperature is too low
Temperature limitation activated
Temperature sensor
Heating cartridge
Temperature controller faulty
SST module faulty
Increase nominal temperature
(see pg. 14 3.4.1)
Switch off the sealing device and allow it to
cool down
!
If it still trips it is imperative to have
the sealing device tested
Replace temperature sensor*
Check heating cartridges and replace if
necessary*
Replace temperature controller*
Replace SST module
No transport
Transport belt
-damaged
-no transport
Front flap not closed
Motor sensor
Front flaps sensor
Motor
Temperature controller faulty
Replace transport belt
Check belt tension
Close front flap
Replace light barrier*
Replace front flap sensor*
Replace motor*
Replace temperature controller*
Содержание hd 650 DC EcoPak
Страница 44: ...hd 650DC EcoPak D Chapter 6 9 693 024 Page 44 V 1 02 6 Declaration of conformity ...
Страница 45: ...hd 650DC EcoPak D Chapter 6 9 693 024 Page 45 V 1 02 ...
Страница 46: ...hd 650DC EcoPak D Chapter 6 9 693 024 Page 46 V 1 02 ...
Страница 47: ...hd 650DC EcoPak D Chapter 6 9 693 024 Page 47 V 1 02 ...
Страница 49: ......