1. Introduction

The SERIES 2000 and SERIES 2000-SAN are solid-state pressure- and level transmitters based upon a bridge resistive silicon 
sensor, with a very high burst pressure. The sensor element is mounted in a stainless steel foot. A very strong stainless steel 
“flush” diaphragm protects the sensor from the process medium. Special oil fills the chamber surrounding the sensor and transfers 
pressure from the flush mounted diaphragm to the sensor. 

Pressure exerted on the sensor element creates a very small deflection of the silicon substrate and bridge network. The resulting 
strain in the silicon resistors causes a change in the bridge resistance that is proportional to the pressure applied. The transmitter 
electronics detects this change in bridge resistance and converts it into 4-20 mA. The amplifier system is based on a single 
Integrated Circuit, which ensures a perfect linearity in the 4-20 mA output.

Together with the 

Flush Diaphragm Technology (FDT)

 the long term stability is perfect.

The Series CER-2000 are “All Stainless” pressure transmitters based on a ceramic pressure cell, with very high burst pressure. 
These transmitters do not have oil filling.

Series  2000  HART                                                             

1.1 Description Series 2000-SAN

The SERIES 2000-SAN are specially 
designed with a flush mounted 
diaphragm so they fully meet the 
needs of the food, chemical and 
pharmaceutical industries.

The Series 2000-SAN is available 
as 3-A version (Sanitary Standard - 
Option G153) and EHEDG (Sanitary 
standard – Option G150).

Standard the wetted parts are made of 
SS 316 , other materials are available.

Various process connections can be 
delivered, such as Tri-Clamp(1,5”, 2” 
and 3”), SMS (1,5” and 2”), dairy milk 
couplings (NW25,40 and 50), flanges 
and very sanitary weld-on nipples (ø 
62 and 85 mm).

1.2 Description Series 2000

The SERIES 2000 are specially 
designed for the pulp- and paper 
industry or similar, where clogging 
is a problem. The very compact 
construction of the SERIES 2000 
permits flush installation with the tank- 
or pipe wall. Standard the wetted parts 
are made of SS 316, other materials are 
available. 

All transmitters are fully temperature 
compensated, which means that 
various process temperatures have 
nearly no effect on the accuracy of the 
output signal. When a failure occurs, 
the transmitter is repairable. However, 
for optimum accuracy the transmitter 
has to be send back to the factory.

1.3 Description Peramic “S” (Series CER 2000)

The Series CER-2000 are pressure 
transmitters based on a ceramic 
pressure cell, which can be used for 
all gauge- and absolute pressure 
measurement on steam (with syphon), 
liquids and gases.

These transmitters do not have oil 
filling.

1.4 Description HYDROBAR (Series 2000 - Hydrobar)

The series 2000-Hydrobar is a complete range of submersible 
level transmitter for top mounting. The 2000-Hydrobar can be 
used  in fluids like waste water, mud, pulp and chemicals. As 
standard the cable material is polyethylene. The connections for 
the wetted parts from the 2000-Hydrobar to the cable are from 
Viton® FKM.

1.5 Barometric Reference

The SERIES 2000-SAN are “relative transmitters” which means 
that barometric changes will not affect the zero (4 mA). The 
venting (4) is placed at the side of the electronic housing and is 
the barometric reference to atmospheric. The venting must be 
kept clean.

Series 2000-SAN

Series 2000

Series CER 2000

Содержание Intelligent 2000 Series

Страница 1: ...tch Series A Higher Level of Performance Instruction Manual HART www hawkmeasurement com For more information please visit Series 2000 SAN Series 2000 Series CER 2000 Series 2000 Hydrobar Intelligent...

Страница 2: ...e Revisions 10 5 Function of Push Buttons 11 6 Programming Points P101 P114 12 7 Reading On The Display 12 8 Explanation Programming Points P101 to P114 13 P101 Zero Adjustment 4 mA 13 P102 Span Adjus...

Страница 3: ...6 other materials are available Various process connections can be delivered such as Tri Clamp 1 5 2 and 3 SMS 1 5 and 2 dairy milk couplings NW25 40 and 50 flanges and very sanitary weld on nipples 6...

Страница 4: ...enting SS 304 4 Venting PA 5 PG9 Cable Gland 6 O ring 2 pcs EPDM 7 Electronics housing SS 304 8 Foot with cooling fins SS 304 9 O ring Viton 10 O ring Viton 11 M8 bolt SS 316 12 Diaphragm and ring SS...

Страница 5: ...2x O ring EPDM 7 Electronics housing SS 304 8 2x Connection to cable SS 316 9 Cable with venting tube PE 10 Foot SS 316 11 Diaphragm protection cap PE 12 Diaphragm SS 316L 13 Mounting bracket 2 holes...

Страница 6: ...eft Allow adequate cooling between passes To reduce the chances of distortion to the weld on nipple use a mandrell SERIES 2000 SAN Part nr 1019 SERIES 2000 Part nr 1016 The position of the electronic...

Страница 7: ...transmitter will be calibrated at the maximum span 3 9 Wiring The push buttons Zero Span and Prog are under the other cover 1 External loads must be placed in the negative leg of the 2 wire loop The f...

Страница 8: ...00 Ohm 36 Vdc RI max Power Supply 12 Vdc 20 mA 4 4 Intrinsically Safe and NON SPARKING Ex version The Series 2000 Series 2000 SAN Series CER 2000 and Series 2000 Hydrobar cable are also available for...

Страница 9: ...0 9 W linear source Li 1 4 mH Ci 63 nF without cable between terminals 3 and 4 Cable length The maximum length of the cable for the Series 2000 Cable 2000 SAN Cable and 2000 Hydrobar Cable is 100 m El...

Страница 10: ...WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESE 4 6 Tracebility Year of Manufacturing The year of manufacturing of the transmitter can be traced as follows take the first two numbers from the serial number...

Страница 11: ...be held until the word SPAN appears on the display The transmitter is now adjusted at 20 mA The span can also be adjusted without test pressure see P102 2 Secondly this button must be used for steppin...

Страница 12: ...nP 3 temperature Hect 4 hectoliters CB n 5 Cubic meters Ltr 6 Liters P110 Simulation of current P111 Linearisation 0 no linearisation 1 cylindrical tank 2 vertical tank with cone 3 vertical tank with...

Страница 13: ...01 Span Adjustment 20 mA Without Test Pressure Before adjusting the span take care the right pressure unit is selected See also P104 and P109 Example Adjustment of the span at 0 2 bar First off all th...

Страница 14: ...ng with software revision 1 will direct process cancel mounting position P103 Adjustment Pressure Unit On Display See Conversion Table P104 104 Conversion Factor Display 1 1 000 mH2 O mWC 2 1000 m H2...

Страница 15: ...pressure appears on the display again P107 Temperature In o C OR o F The temperature of the transmitter is standard adjusted at o C DEGR When pushing h in P108 this will change into o F FAHR Always co...

Страница 16: ...he simulation Pressure simulation Unit To perform a pressure simulation follow the next steps 1 Push PROG until 100 is shown on the display 2 Push h SPAN 10 times until 110 appears on the display 3 Co...

Страница 17: ...111 appears Confirm with PROG 3 Push h once Confirm with PROG 4 Enter the height H1 of the tank in meters Confirm with PROG 5 Enter the same height H2 of the tank in meters Confirm with PROG 6 Enter...

Страница 18: ...the height H3 from the bottom of the tank to the topside of the diaphragm or weld on nipple Confirm with PROG 8 Enter the percentage of the actual full level for example 80 Confirm with PROG Note Whe...

Страница 19: ...ears on the display 4 Push h i for adjusting to ON or OFF 5 Push PROG to confirm Adjustment Communication Protection 1 Push PROG till 100 appears on the display 2 Push h SPAN 13 times untill 113 appea...

Страница 20: ...he Series 2000 HART transmitters easy This DTM can be used with almost every FDT container To be able to install the DTM Klay Series 2000 HART on your system download the installation file This file c...

Страница 21: ...00 bar Series CER 2000 1 0 0 2 bar 0 0 8 bar 5 bar 2 0 0 8 bar 0 2 bar 10 bar 3 0 2 bar 0 10 bar 30 bar 4 0 10 bar 0 40 bar 120 bar 5 0 40 bar 0 200 bar 350 bar 6 0 150 bar 0 320 bar 600 bar Process T...

Страница 22: ...n nipples It also prevents the screw thread from the Series 2000 SAN M56 x 1 25 from being deformed The diaphragm of the transmitter is protected with a special protection cap Protect the diaphragm un...

Страница 23: ...Overview Attachment EC Declaration of conformity 23 Series 2000 HART...

Страница 24: ...rs Series 2000 HART Hawk Measurement Systems Head Office 15 17 Maurice Court Nunawading VIC 3131 AUSTRALIA Phone 61 3 9873 4750 Fax 61 3 9873 4538 info hawk com au Hawk Measurement 5010 Gateway Drive...

Отзывы: