11 Maintenance
11.1
Maintenance
Please consider that the laser measuring heads and the accessories are precision
instruments. Make sure that these instruments are used and maintained with utmost care.
11.2
Replacing the batteries in the laser housing
To open the battery compartment in the laser housing,
(Illustration 42)
unscrew the black
cap.
(Illustration 43)
Battery type: Mignon Type AA 1.5V
The surfaces of the magnetic feet have to be kept clean of dirt, as
only that way an all-over and firm attachment to the rim can be
ensured.
The lense of the laser head can be cleaned with a dry and soft
cloth, if necessary. Do never clean with alcohol or any other
liquids.
The life of the batteries for the inclinometer is approx. 60 h in
normal operation (without lighting)
If the capacity of the installed batteries is no longer sufficient a
battery symbol is displayed and the batteries must be replaced.
The unit continues to work correctly even if the battery power is
weak. It does not display any incorrect angle values in relation
to the measurement taken.