INSTALLATION INSTRUCTIONS
ZON
3
2
ZON
2
ZON
1
ZON
0
2
3
ZON
3
2
2
ZON
2
ZON
1
2
ZON
0
60 CM
60 CM
60 CM
60 CM
Page 2
FIG. 1
IMPORTANT:
*
Before installing your towel-drier radiator, ensure that the main switch on your mains board is switched off.
* Verify that there is a mains connection close to where the appliance is to be installed.
* This Haverland towel-drier radiator is designed to be fixed to a wall.
* It must not be installed below or in front of a mains socket.
* This appliance must be connected only to 230 V 50 Hz. Verify that the radiator voltage coincides with the mains voltage
to which it is to be connected.
* The junction box must have the same degree of protection against humidity as the towel-drier radiator, PROTECTION
DEGREE: IP44.
* A breaker, with a minimum 3-mm contact separation for all poles shall be installed directly to the mains power terminals
to ensure single-pole switch-off.
* The electrical installation shall be performed in accordance with current electrical legislation and include the means to
switch off the fixed installation. The electrical line shall be protected by a high-sensitivity earth leakage breaker.
* The mains power cable must never be cut.
* The appliance mains power cable shall be connected to the mains system via a junction box.
* It is essential that the towel-drier radiator IS SECURELY FIXED TO A STRONG, LEVEL WALL. Verify that the radiator is
COMPLETELY VERTICAL with respect to the floor. It is very important that these recommendations are carefully followed.
* 600 mm is the minimum distance between the thermostat and the floor.
* This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabi-
lities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of
appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the
appliance.
DANGER
Only you can to install the towel in
zone 2 and 3.
DO NOT USE THIS HEATER IN THE
IMMEDIATE OF A BATH, A SHOWER
OR A SWIMMING POOL (zone 0 and
zone 1) (see Fig 1).
E
E
E
E
E
E
E
E
Page 16