MAINTENANCE
44
ENGLISH
(2) 45° BEVEL ANGLE (fig. 32-34)
Adjust the 45° bevel angle only after performing 0° bevel angle adjustment. To
adjust left 45° bevel angle, loosen the lever and tilt the blade to the left fully. (fig. 32)
Carefully measure the angle of the side of the blade with the top surface of the rotary
table using the 45° triangular rule. Turn the left 45° bevel angle adjusting bolt on
the arm slightly counterclockwise or clockwise to tilt the blade to the right position.
Then tighten the lever securely. (fig. 33)
Make sure that the pointer on the arm point to 45°. If the pointer does not point to
45°, adjust the pointer to 45° on the scale by loosening the screw, and then tighten
the screw. (fig. 34)
CHANGE THE CARBON BRUSH (fig. 35)
Remove and check the carbon brushes regularly. Replace the carbon brushes
when it is worn out. Keep the carbon brushes clean and free to slip in the holders.
Both carbon brushes should be replaced at the same time.
Use only identical carbon brushes. Use a screwdriver to remove the brush holder
caps. Take out the worn carbon brushes, insert the new ones and secure the
brush holder caps. (fig. 35)
fig.32
Lever
fig.35
Brush holder caps
Screwdriver
fig.33
Triangular rule
Blade
Rotary table
fig.34
Bevel scale
Pointer
Screw