![Haug Multistat Ex SDN Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/haug/multistat-ex-sdn/multistat-ex-sdn_operating-instructions-manual_2107707021.webp)
6 Troubleshooting
21
6.2
Flow diagram 1
Proceed with troubleshooting of all components exclusively outside
of the Ex zone.
The error lamp is blinking.
Discharging power pack
defective
Switch off the discharging power pack and unplug
the ionizing units.
Switch on the discharging power pack.
yes
Switch off the discharging power pack and plug in an
ionizing unit.
Switch on the discharging power pack.
This ionizing unit is faulty.
(Short circuit)
Ionizing system is ok
no
no
no
yes
yes This ionizing unit is faulty.
(Short circuit)
Switch off the discharging power pack and plug in
another ionizing unit.
Switch on the discharging power pack. etc.