5
Application
Preconditions:
The charging generator and the charging electrode must be connected correctly.
Protective equipment against direct contact with the charging electrode must be provided.
The unit may be put into operation by trained electricians only or by authorized persons
instructed in the potential dangers. The above mentioned persons must have read the operating
instructions and must follow the instructions, notes and safety advice.
5.1
Putting into operation
1.
Turn high voltage potentiometer to the extreme left (minimum).
2.
Switch on the charging and discharging units by switching the On/Off switch to On. The
green control lamp in the switch lights up.
3.
Set high voltage potentiometer to desired value. The voltage measuring instrument (Fig. 2)
will indicate the voltage set.
5.2
Instructions for setting the high voltage
The output voltage depends on the current load. This is why the voltage increases if an existing
counter-electrode is covered with insulating material.
If spark-over occurs, please set a lower voltage or increase the distance between the charging
electrode and the counter-electrode or the opposing metal parts.
6
Remedy of defects
Any remedy of defects must be carried out by trained electricians only. The above mentioned
persons must have read the operating instructions and must follow the instructions, notes and
safety advice.
In case of malfunctions in connection with the charging generator, first check its correct
installation and fusing (for replacement refers to Section 7.1). If this does not solve the problem,
please return the charging generator and the charging electrodes for a check-up.