Art. Nr.: 5090033070
Rev.: 03/2019-06-13
PolySafe sealing elements and sleeve caps
EN
1a
Remove blind plug.
For the application range 32 mm, the blind plug
is removed from the universal sealing element WD
(see fig.: 13).
1b
Push the segment ring together.
After this, the first segment ring is pressed on both
sides until a continuous crease is formed (see fig.: 14).
1c
Rotate the segment ring to remove.
The segment ring is turned vigorously at this crease
so as to remove it (this can also be done using a
screwdriver) (see fig.: 15).
1d
Areas of application: 50 mm
Remove second segment ring.
In order to remove the second segment ring
(dia-
meter 50 mm)
, proceed as described in stages 1b
to 1c (see fig.: 16).
5.2 * PolySafe ED 1/20-34 -
Universal sealing element for
electricity
Legend for Fig.: 17
1
Universal sealing element
2
Attachment tab
3
Segment ring
4
Blind plug
Areas of application:
ø 20-26 mm
ø 26-34 mm
1
Remove blind plug and segment ring where
applicable.
See
work stages 1a to 1d in section
5.1
(see fig.: 18).
Legend for Fig.: 12
1
Universal sealing element
2
Attachment tab
3
Segment ring
4
Blind plug
5.3 PolySafe ED 1/26-29, 36-39, 43-
46, 48-51 -
Universal sealing element for
electricity
Areas of application:
ø 26-29 mm
ø 36-39 mm
ø 43-46 mm
ø 48-51 mm
Legend for Fig.: 19
1
Universal sealing element
2
Attachment tab
3
Segment ring
4
Blind plug
1
Remove blind plug and segment rings where
applicable.
See
work stages 1a to 1d in section 5.1
(see
fig.: 20)
5
Description and installation of
sealing elements
5.1 * PolySafe WD 1/32/40/50 -
Universal sealing element for
water
Areas of application:
ø 32 mm
ø 40 mm
ø 50 mm
Area of application
Segment
ring
Cable range d
(mm)
3/7-13
Plug
Ø 7-9
Nr. 1
Ø 10-13
1/5-13
Plug
Ø 5-7
Nr. 1
Ø 8-13
Individual sleeve cap
z/d
-
Ø d
a
(+1/-2)
5.4 PolySafe ED/KD 1/26-30 + 3/5-8 +
2/7-13 -
Universal sealing element for
electricity and communication
Areas of application:
1x ø 26-30 mm
3x ø 5-8 mm
2x ø 7-13 mm
Legend for Fig.: 21
1
Universal sealing element
2
Attachment tab
3
Segment ring
4
Blind plug with sleeve
1
Remove blind plug and segment rings where
applicable.
In the case of the electricity/telecommunications
sealing element, the relevant blind plugs and seg
-
ment rings are removed as necessary (see fig.: 22).
See
work stages 1a to 1d in section 5.1.