Safety information 

 

2.1 

General 

 

The safety information is designed to protect people and property from damage and hazards 
resulting from unintended use, incorrect operation or other negligent handling of devices, 
especially in potentially explosive atmospheres. For this reason, you should read this instruction 
manual carefully before undertaking any work on the product or commissioning it. The 
instruction manual must be accessible to operating personnel at any time. 

Please check that all documentation is in place prior to commissioning or other work on the 
product. If not all documentation has been handed over in full, or if further copies are required, 
then they can also be sourced in other languages. 

The product has been constructed to the state of the art. Nevertheless, it is impossible to rule 
out dangers emerging from this product which could endanger people, machines and systems, 
should it be subject to inappropriate handling, non-intended use or use and maintenance by 
insufficiently trained persons. 

Every person employed by the operator and involved in the set-up, operation and maintenance 
of this product must have read and understood this instruction manual.  

The product may only be assembled, disassembled, installed and repaired by instructed, 
sufficiently trained and authorised personnel. 

 

2.2 

Symbols used 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This symbol indicates a risk of explosion. 

 

 

 

This symbol indicates a risk of electric shock. 

 

 

 

This symbol points to non-safety-related information. 

 

 

Scope of this instruction manual 

 

This instruction manual for the HE103-type vibration monitoring unit applies to the following 
variants:  
Standard / ATEX / IECEx / EACEx 

The functionality of the versions is identical. The ATEX / IECEx / EACEx versions also possess 
certifications and labels which permit use in potentially explosive atmospheres. For further 
information, see chapter "Application areas and type plate examples

 on page 6. 

 

 

 

Содержание HE103 Series

Страница 1: ...ing unit HE103 series Vibration velocity mm s rms ATEX IECEx EACEx Zone 1 2 21 22 Analogue current output 4 20 mA Frequency ranges 10 Hz 1 000 Hz 1 Hz 1 000 Hz Extended rms averaging time T 60 s Manuf...

Страница 2: ...or to commissioning the product the instruction manual must be read and understood All rights including translation are reserved Subject to changes Should any question arise please contact HAUBER Elek...

Страница 3: ...housing 7 11 Technical data 8 11 1 General data 8 11 2 Electrical data 8 11 3 Permitted operating temperature ranges 9 11 4 Operating range of the vibration monitoring unit 10 11 5 Typical frequency...

Страница 4: ...s product which could endanger people machines and systems should it be subject to inappropriate handling non intended use or use and maintenance by insufficiently trained persons Every person employe...

Страница 5: ...ons include Vibration monitoring unit Instruction Manual 7 Documents and certificates The following documents and certificates pertaining to type HE103 can be viewed and downloaded here http www haube...

Страница 6: ...e resistant casing Ex db Protection through housing Ex tb Application area Atmospheres not at risk of explosion Potentially explosive atmospheres of zones 1 and 21 2 and 22 Marking Type plate Standard...

Страница 7: ...lowing conditions must be met for safe operation in potentially explosive atmospheres 10 1 HE103 01 protection pressure resistant housing Electrical data min typ max Supply voltage Un 10 V DC 24 V DC...

Страница 8: ...IN ISO 2954 Cross sensitivity 5 Frequency range 10 Hz 1 000 Hz standard 1 Hz 1 000 Hz Calibration point 159 2 Hz and 90 amplitude of the measuring range Maximum acceleration 16 5 g Service life 10 yea...

Страница 9: ...es Version Ambient temperature TA Measuring head temperature in the fixing area Standard 40 C to 60 C 40 C to 125 C ATEX IECEx EAC Pressure resistant casing Ex d Protection through housing Ex tb 40 C...

Страница 10: ...ibration 2 Fig 1 shows the operating range of the vibration monitoring unit which is limited by the maximum measurable vibration velocity in mm s depending on the frequency in Hz Fig 1 Operating range...

Страница 11: ...z 1 200 Hz acceleration sensor Fig 2 Typical frequency response 10 Hz 1 000 Hz 1 Frequency in Hz 2 Amplification in dB 1 Hz to 1 000 Hz The frequency response is recorded using two reference sensors 1...

Страница 12: ...d Assembly type Standing vertical or lying horizontal Measurement direction Along the fixing axis Max torque oft the Sensor 8 Nm Max torque of the M12 union nut on the connector 0 4 Nm Weight ca 200 g...

Страница 13: ...tronik GmbH 13 11 7 2 Version ATEX IECEx EACEx Ex d Fig 5 Housing with integrated cable All dimensions in mm 1 Cable gland for integrated cable 2 Width A F 24 3 Fixing 4 Measuring direction along the...

Страница 14: ...otection through housing Ex tb integrated cable brown Pin 1 10 30 V DC white Pin 2 NC blue Pin 3 4 20 mA black Pin 4 NC PUR sheathed cable approx 6 5 mm 4 pole 0 34 mm NC Not connected The system oper...

Страница 15: ...k steps and instructions Screw vibration monitoring unit into the threaded hole of the mounting surface in a friction locked manner using a hex key The tightening torque should be 8 Nm The tightening...

Страница 16: ...loops are amongst the most common problems in measurement set ups with sensitive sensor technology These issues arise due to unintentional differences in potential in the electrical circuit between t...

Страница 17: ...earth connection can only be ensured for versions with an M12 plug connection For versions with an integrated cable the alternative earthing concept cannot be used 1 Machine earth 2 Evaluation unit me...

Страница 18: ...o measured value 4 20 mA No voltage supply Check voltage source and or supply cable Connection cable interrupted Replace connection cable Fuse defective Replace fuse Connection has incorrect polarity...

Страница 19: ...ding to local regulations and legislation 17 Accessories Accessories Standard ATEX IECEx Ex d tb Factory calibration certificate x x Evaluation device types 652 and 656 x x HE400 type portable measuri...

Страница 20: ...ECEx EACEx Ex d and Ex tb zones 1 2 21 22 Measuring range 8 8 mm s rms only for frequency range 10 Hz available 16 16 mm s rms standard 32 32 mm s rms 64 64 mm s rms 128 128 mm s rms Frequency range 0...

Страница 21: ...UBER Elektronik GmbH Fabrikstra e 6 72622 N rtingen Zizishausen Germany declare of our own accord that the product vibration sensor monitoring unit evaluation devices to which this declaration refers...