![Hatz 2-4L30 Скачать руководство пользователя страница 170](http://html1.mh-extra.com/html/hatz/2-4l30/2-4l30_workshop-manual_2107423170.webp)
4
L / M . . / 07.96
Trouble-shooting table for electrical system
Trouble-shooting at the pre-heat system
Malfunction
Spiral indiator element
(pre-heat monitor) glows
brightly almost immedi-
ately.
Interruption of pre-glow
device pre-heat monitor
does not burning.
Cause
Short to earth (ground) in a pre-
heat plug, pre-heat element (fila-
ment) is bent and shorting inside
engine.
Broken pre-heat wires in a line
resistor, winding shorted to an
earthed component.
Since the pre-heat monitor, pre-
heat plug or heating flange (and
also the second pre-heat plug or
line resistor on 24 V systems) are
wired in series, the complete pre-
heat system is out of action if a
component fails.
Remedy
Renew the pre-heat plug.
Renew the line resistor.
Use a test lamp or a voltmeter (with
the pre-heat system switched on)
to check all the pre-heat monitor
connecions.
Renew defective parts.
Содержание 2-4L30
Страница 2: ......
Страница 6: ......
Страница 7: ...1 L M 10 98 1 General...
Страница 22: ......
Страница 23: ...2 L M 09 96 2 Additional equipment...
Страница 47: ...3 Basic engine 3 L M 09 96...
Страница 134: ......
Страница 135: ...4 L M 07 96 4 Tables...