background image

 

6.  TROUBLESHOOTING 

Problem 

Possible Cause(s) 

Solution(s) 

Pump does not build pressure

 

Bleed valve open 

Close the bleed valve. 

Hose disconnected 

Connect test plug or fill reservoir. 

Rebuild required 

Use included O-ring kit to replace 

any damaged O-rings or valve parts. 

Pump builds pressure slowly or leaks 

while filling

 

System leak 

Perform leak test.  Follow 

instructions on pg 5 (3-8,9,10). 

Bleed valve not fully closed 

Close the bleed valve securely. 

Reservoir leak 

Refer to your airgun or reservoir 

manufacturer’s instructions.

 

Rebuild required 

Use included O-ring kit to replace 

any damaged O-rings or valve parts. 

Pump is difficult to operate

 

High pressure 

Pump may require 200 lbs of force 

to operate at max (4500PSI) 

pressure. 

One-way valve stuck or 

damaged 

Use included O-ring kit to replace 

any damaged valve parts. 

If you experience a problem that is not covered by this troubleshooting guide, or if you continue 
to have the same problem, discontinue use and contact HatsanUSA ([email protected] or 
(877)-278-4448 x201) for assistance. 

5.  MAINTENANCE 

Proper maintenance of your hand pump is critical to its longevity.  Failure to properly maintain it 
will result in premature failure, and may void your warranty. 

• 

Use only approved filters, hoses, fittings, and accessories.  It is your responsibility to check 
for leaks before using to fill. 

• 

Use only high quality silicone-based oil for lubrication.  Failure to do so may result in 
accelerated wear and premature failure.  Only place oil on the pump shaft.  DO NOT 
ALLOW OIL TO ENTER THE AIR INLET! 

• 

To reliably produce clean and dry air, the dryer filter media must be monitored on a regular 
basis and changed when necessary.  Filter life will vary due to many factors, including but 
not limited to: humidity, temperature, purge frequency, and cycle times. 

• 

Filters are easily replaced by unscrewing the filter body from the hose using the 
included spanner wrenches. 

• 

Certain climates and operating conditions may warrant the use of an additional inline 
filter.  Contact HatsanUSA or your retailer to order this part. 

• 

Parts of this hand pump could become hot enough to cause burns.  If the pump becomes 
hot to the touch, discontinue use immediately and allow it to cool down to room 
temperature.  Failure to do so may result in premature seal and valve failure. 

Содержание TactAir

Страница 1: ...TactAir 4 Stage PCP Hand Pump Operation Manual...

Страница 2: ...are recommended during use 4 The hand pump should only be dismantled by a competent technician otherwise serious damage injury death may be caused to you or others 5 Improper disassembly reassembly w...

Страница 3: ...manual purge discharge opening The escaping air can cause damage Noise from purging may be loud especially if you are in a small space Hearing protection is recommended while using this hand pump When...

Страница 4: ...4 1 INCLUDED TOOLS FOR ASSEMBLY 2 PARTS OF YOUR HAND PUMP Tool Type Tool Use Quantity L Shaped Hex Key Attach Pump Handle Hardware X 1 Multi size Spanner Wrench Attach Gauge Attach Hose X 2...

Страница 5: ...indication of pressure loss 9 If any leaks are detected open the bleed valve and tighten the fitting at which the leak occurred 10 Repeat steps 8 and 9 at 3000 and 4500 PSI DO NOT OVER PRESSURIZE 11...

Страница 6: ...NTENANCE Proper maintenance of your hand pump is critical to its longevity Failure to properly maintain it will result in premature failure and may void your warranty Use only approved filters hoses f...

Страница 7: ...to manufacturing defect including parts and labor Return shipping of the repaired or replaced product back to the consumer What Is NOT Covered Repairs required due to abuse misuse neglect or failure t...

Страница 8: ...8 www HatsanUSA com facebook com HatsanUSA instagram com hatsan_usa youtube com c HatsanUSAInc HatsanUSA Inc PO Box 576 Bentonville AR 72712 P 479 273 5629 F 918 517 3040...

Отзывы: