UNPACKING
1. Remove unit from box.
2. Remove information packet.
To prevent delay
in obtaining warranty coverage, fill out and
mail in warranty card to Hatco.
3. Remove tape, glass protection corners and
packaging material from all surfaces of unit.
4. The unit is equipped with both a top set and
bottom set of pins for supporting the wire plate
rack. Properly position the wire plate rack using
either set, making sure the wire rack is placed
between the three lower pins and the upper pin
on each side. (See Figure 4).
NOTE: Top wire plate position is recommended for
quick flash heating only. All items listed in the Food
Finishing Guide are utilizing the bottom set of pins
for supporting the wire plate rack.
LOCATION
WARNING
To reduce the risk of fire, the TFW-461R
appliance is to be mounted on floors of
noncombustible flooring and surface finish with
no combustible material against the underside,
or on noncombustible slabs or arches, have no
combustible material against the underside.
Such construction shall in all cases extend not
less than 12" (305 mm) beyond the equipment
on all sides.
WARNING
For safe and proper operation, the unit must be
located a reasonable distance from combustible
walls and materials. If safe distances are not
maintained, discoloration or combustion could
occur. Do not locate unit under shelving or
closer than 12" (305 mm) from the ceiling.
WARNING
On TF-1919, TF-4619 and TF-461R models allow
a minimum of 1" (25 mm) clearance along the
sides and back. Allow a clearance of 26"
(660 mm) along the front discharge to ensure
proper operation and safety.
WARNING
To avoid any injury or damage to the unit do not
pull unit by power cord.
WARNING
To prevent any injury, discontinue use if power
cord is frayed or worn.
Form No. TF1946M-1004
5
INSTALLATION
WARNING
On TFW-461R models allow a minimum of 1"
(25 mm) clearance along the right wall and back
wall when facing controls. Allow 3" (76 mm)
along the left wall. Allow a clearance of 26"
(660 mm) along the front discharge to ensure
proper operation and safety.
CAUTION
To avoid any injury or damage to the unit make
sure the plate rack is not in direct contact with
the glass base.
CAUTION
To avoid any injury or damage locate the unit at
the proper counter height, in an area that is
convenient for use. The location should be level
to prevent the unit or its contents from
accidentally falling, and strong enough to
support the weight of the unit.
CAUTION
Do not place anything on top of the unit; doing
so could damage the unit or subject personnel
to possible injury.
Figure 4. Rack Support Placement