background image

Form No. HWBIM-0319

15

English

INSTALLATION

  2.  Remove the trim cover from the control enclosure.
  3.  Position the control enclosure into the opening through the 

backside.

  4. Secure the control enclosure to the mounting surface 

using screws (#8 sheet metal screw supplied).

Typical knockout

locations for power

source connection.

Control

Enclosure

 5. Connect the proper power 

source to the mounted remote 

control enclosure. Wiring 

must be fixed a minimum of 4″ 

 

(102 mm) from bottom of 

well(s). 

  6.  Connect the water supply to 

the optional Auto-Fill system, 

if equipped. Refer to the 

“Side Mounted Auto-Fill” or 

“Drain Mounted Auto-Fill” procedure in the OPTIONS AND 

ACCESSORIES section.

 7. Reinstall the trim cover. Seal the trim cover to the 

mounting surface with silicone adhesive.

NOTE: Standard UL approved units are equipped with a 72″ 

(1829 mm) flexible conduit connected to the remote 

control enclosure. 

Connecting A Drain Line

After installing a drain- or manifold-equipped unit into the 

countertop, use the following procedure to connect the 

unit to the on-site drain line. Refer to the OPTIONS AND 

ACCESSORIES section for external manifold drain with valves 

information.

CAUTION

BURN HAZARD: Drain water may reach temperatures 

in excess of 200°F (93°C). Use appropriate plumbing 

materials when installing drain.

NOTE: Consult a licensed plumbing contractor for proper drain 

installation that conforms to local plumbing codes.

NOTE: Approved air gap or other back-flow prevention device 

must be installed by a licensed plumber, if required.

Individual Drain Units

  1.  Connect drain pipe (supplied by others) from the 3/4″ NPT 

drain fitting(s) on the bottom of the well(s) to a 3/4″ drain 

valve (supplied by others or available as an accessory 

from Hatco—refer to the OPTIONS AND ACCESSORIES 

section).

NOTE: The drain valve(s) must be installed in an easily 

accessible location for the operator.

  2.  Connect the drain valve to the on-site drain line (supplied 

by others).

To drain

3/4″ Drain Valve

3/4″ Drain Fitting

(inside unit)

14″

(356 mm)

on

center

Individual Drain Connection

Manifold Drain Units

  1.  Connect drain pipe (supplied by others) from the 1″ NPT 

manifold drain fitting to a 1″ drain valve (supplied by others 

or available as an accessory from Hatco — refer to the 

OPTIONS AND ACCESSORIES section). 

 

• Side/End Drain: manifold drain fitting located on either 

end of the unit.

 

• Bottom Drain: manifold drain fitting located on the 

bottom at either end of the unit.

NOTE: The drain valve must be installed in an easily accessible 

location for the operator.

  2.  Connect the drain valve to the on-site drain line (supplied 

by others).

1″ Drain Valve

1″ Manifold

Drain Fitting

To drain

Side Manifold Drain Connection

Содержание HWBI Series

Страница 1: ...io lesión o muerte Este manual contiene importante información sobre seguridad concerniente al mantenimiento uso y operación de este producto Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor Almacenar este manual en una localización segura para la referencia futura ADVERTENCIA Ne pas utiliser cet équipement sans avoir lu et compris le contenu de ce manuel L...

Страница 2: ...can be found by visiting our web site at www hatcocorp com INTRODUCTION Hatco Modular Built In Heated Wells are specially designed to hold heated foods at safe serving temperatures Designed for dry or wet applications the wells are available in a variety of pan combinations all heated with a long life heating element that is covered by a 2 year part warranty The metal sheathed heating element is c...

Страница 3: ... unit is not intended for use by children or persons with reduced physical sensory or mental capabilities Ensure proper supervision of children and keep them away from unit WARNING Make sure all operators have been instructed on the safe and proper use of unit Make sure food product has been heated to the proper food safe temperature before placing in the unit Failure to heat food product properly...

Страница 4: ...nit must be allowed to cool down to room temperature before changing from wet to dry or dry to wet operation Allowing unit to run dry during wet operation or adding water during dry operation will damage unit Drain sealants must have temperature rating of 500 F 260 C or higher Incoming water pipes must be FDA compliant for potable water H W B L I x x x A Heated Well Built In No Character Without A...

Страница 5: ...D models have the same capabilities as the HWBI X models but are equipped with a separate drain in each well Each drain includes a 3 4 NPT drain fitting and a flat drain screen that allows for pans to stay level for consistent temperatures HWBI 1DA 2DA 3DA 4DA 5DA and 6DA Models HWBI XDA models have the same capabilities as the HWBI XD models but are also equipped with the Auto Fill feature NOTE A...

Страница 6: ...nly the left hand well To fill all wells drains must be connected to a manifold HWBI43 2M 3M 4M 5M and 6M Models HWBI43 XM models have the same capabilities as the HWBI43 X models but are equipped with a manifold drain assembly The manifold drain assembly is equipped with a 1 NPT drain fitting Each well connected to the manifold drain assembly includes a flat drain screen that allows for pans to s...

Страница 7: ...ONS Dimensions HWBI X Models Side View A B C 7 9 16 192 mm 3 76 mm Side Drains 7 178 mm Front View 14 356 mm Bottom Drains 5 16 8 mm Flange Units with over sized bezel option have a Depth B of 27 686 mm Model Width A Depth B Height C HWBI43 1 15 1 2 394 mm 30 3 8 772 mm 9 5 8 244 mm HWBI43 2 29 1 2 749 mm 30 3 8 772 mm 9 5 8 244 mm HWBI43 3 43 1 2 1105 mm 30 3 8 772 mm 9 5 8 244 mm HWBI43 4 57 1 2...

Страница 8: ... 110 F 43 C SPECIFICATIONS Water Supply Specifications Auto Fill Units NEMA 6 50P NEMA 6 30P NEMA 6 20P NEMA 6 15P NEMA 5 15P NEMA 5 20P NEMA 5 30P Plug Configurations NOTE Receptacle not supplied by Hatco Plug Configurations Some units are supplied from the factory with an electrical cord and plug installed Plugs are supplied according to the application Refer to the OPTIONS AND ACCESSORIES secti...

Страница 9: ...00 10 1 15 0 1 1 240 1 6015 17 4 3 208 1 6015 28 9 1 NEMA 6 50P 20 1 3 N A 240 1 6015 25 1 1 NEMA 6 50P 17 4 3 N A 220 230 1 2 2415 2640 3600 3935 11 0 11 5 16 4 17 1 1 1 N A 167 lbs 76 kg 230 240 1 2 2218 2415 3306 3600 9 6 10 1 14 4 15 0 1 1 HWBLI 6 120 1 4500 37 5 1 N A 190 lbs 86 kg HWBI 6 and HWBI43 6 208 1 2 3615 3600 17 4 17 3 1 1 208 1 7215 20 1 3 240 1 2 3615 3600 15 1 15 0 1 1 240 1 7215...

Страница 10: ...NOTE To prevent delay in obtaining warranty coverage complete online warranty registration See the IMPORTANT OWNER INFORMATION section for details 2 Remove tape and protective packaging from all surfaces of unit NOTE A qualified electrician should connect the unit s to a power source A qualified plumber should connect the water supply and drain s 3 Install the unit in the desired location Use the ...

Страница 11: ... Mounting 4 Place the unit into the countertop opening and secure with 1 4 20 mounting nuts on the mounting studs Tighten the nuts securely 5 Carefully trim and remove the excess ribbon putty material from around the unit 6 Install the control enclosure s Refer to the Installing a Remote Control Enclosure procedure in this section Through Hole Mounting System NOTE This type of installation is not ...

Страница 12: ...m Through Hole HWBI43 3 EZ Tab 42 1 4 1073 mm 29 1 8 740 mm N A N A HWBI 4 EZ Tab 56 1 8 56 3 8 1425 1432 mm 22 1 4 22 1 2 565 572 mm N A N A Stud 56 1 8 56 5 16 1425 1432 mm 28 3 8 721 mm 22 7 8 581 mm Through Hole HWBI43 4 EZ Tab 56 1 4 1429 mm 29 1 8 740 mm N A N A HWBI 5 EZ Tab 70 1 8 70 3 8 1781 1787 mm 22 1 4 22 1 2 565 572 mm N A N A Stud 70 1 8 70 5 16 1781 1786 mm 35 3 8 899 mm 22 7 8 581...

Страница 13: ...round combustible surfaces and 11 279 mm around non combustible surfaces Allow additional clearance for units equipped with a drain HWBI 1 and HWBI43 1 HWBI 3 and HWBI43 3 HWBI 4 and HWBI43 4 HWBI 6 and HWBI43 6 B A B A B A B A C C C C C C D HWBI 2 and HWBI43 2 B A C D D D D HWBI 5 and HWBI43 5 B A C C D Countertop Cutout Dimensions ...

Страница 14: ...Fill 17 432 mm 4 3 4 121 mm 17 1 4 438 mm 2 1 2 64 mm INSTALLATION Installing a Remote Control Enclosure Remote control enclosures must be mounted on the front of the unit to ensure the controls correspond with the correct wells the front of the unit is the side the conduit enters under the unit Remote control enclosures cannot be rewired and must be installed in the proper location WARNING ELECTR...

Страница 15: ...93 C Use appropriate plumbing materials when installing drain NOTE Consult a licensed plumbing contractor for proper drain installation that conforms to local plumbing codes NOTE Approved air gap or other back flow prevention device must be installed by a licensed plumber if required Individual Drain Units 1 Connect drain pipe supplied by others from the 3 4 NPT drain fitting s on the bottom of th...

Страница 16: ... step 2 in this procedure 2 Place an empty pan in the well or cover the well with a lid This step is recommended to speed up pre heating and reach operating temperature 3 Move the Power I O on off switches to the I on position The indicator light on each switch glows when it is on If the unit is equipped with the Auto Fill option the far left Power I O on off switch will activate the Auto Fill sys...

Страница 17: ... Move the Power I O on off switches to the O off position and allow the unit to cool 2 Remove and wash any pans and adapters 3 Open the drain valve if equipped or manually remove water from the well s if used for wet operation 4 Wipe down the entire unit using a clean cloth or sponge and mild detergent 5 Use a plastic scouring pad to remove any hardened food particles or mineral deposits 6 Rinse t...

Страница 18: ...nce Left hand well not turned on Turn on well Unit is overfilling with water Water level sensor is not sensing minerals in the water supply This is typically due to reverse osmosis water or similar filtration process Auto fill units supplied with water from a reverse osmosis RO system or similiar water filtration system must be installed with an operating reminerialization sytem to assure proper o...

Страница 19: ...ts Food Pans Stainless steel food pans are available in various sizes ST PAN 1 3 Third size stainless steel pan 12 3 4 W x 6 7 8 D x 2 1 2 H 324 x 175 x 64 mm ST PAN 1 2 Half size stainless steel pan 12 3 4 W x 10 3 8 D x 2 1 2 H 324 x 264 x 64 mm ST PAN 2 Full size stainless steel pan at 2 1 2 64 mm deep 12 3 4 W x 20 3 4 D x 2 1 2 H 324 x 527 x 64 mm ST PAN 4 Full size stainless steel pan at 4 1...

Страница 20: ...the depth dimensions of a Hatco cold well Attached Cord and Plug An attached cord and plug is available as a factory installed option for models with a single phase electrical configuration and without an extended control conduit Use the following procedure to install the control 1 Secure the control enclosure to the desired location on the control mounting bracket using supplied screws The cutout...

Страница 21: ...verse osmosis RO system or similiar water filtration system must be installed with an operating reminerialization sytem to ensure proper operation Failure to do so may cause unit to overfill Damage caused by overfilling is not covered under warranty Drain sealants must have temperature rating of 500 F 260 C or higher Incoming water pipes must be FDA compliant for potable water 1 Connect the street...

Страница 22: ...nstall the brass nipple into the drain fitting on the bottom or side of the well 3 Thread the brass tee fitting onto the brass nipple 4 Thread the brass bushing into the side of the brass tee fitting 5 Connect the street elbow to the brass bushing NOTE The fill tube hose may need to be removed from the Plumbing Kit for ease of installation 6 Connect the fill tube hose to the fill valve nipple in t...

Страница 23: ...a 26 660 mm maximum distance from the front of the cabinet to the center of the drain 10 Spread both cotter pin ends to secure the rods inside the couplings Cabinet Wall Ball Valve Coupling Key Rod Cotter Pin Key Clamp Handle Coupling Gate Valve Coupling Remote Drain Handle Assembly Cotter Pin Washers Remote Drain Handle Installation Cabinet Cutaway Remote Drain Handle A remote drain handle option...

Страница 24: ...losure on the right when facing the operator side of the unit to perform the 3 phase conversion 3 Locate the terminal block in the control enclosure and perform the appropriate wiring changes to convert the unit to 3 phase Refer to the proper wiring diagram supplied with unit listed below for the details regarding the wiring changes Wiring Diagram 10 01 549 All HWBI 2 and HWBI 3 units as well as H...

Страница 25: ...E OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights heat lamp bulbs coated halogen light bulbs halogen heat lamp bulbs xenon light bulbs LED light tubes glass components and fuses Product failure in booster tank fin tube heat exchanger or other water heating eq...

Страница 26: ...icié de recherche extensive et d essais sur le terrain Les matériaux utilisés ont été sélectionnés pour une durabilité maximale une apparence séduisante et des performances optimales Chaque unité est inspectée et testée minutieusement avant d être expédiée Informations Importantes pour le Propriétaire 26 Introduction 26 Consignes de Sécurité Importantes 27 Désignation du Modèle 28 Description du M...

Страница 27: ... en vigueur AVERTISSEMENT DANGER DE DÉCHARGE ÉLECTRIQUE Placez l interrupteur sur Arrêt débranchez le cordon d alimentation arrêtez le courant au disjoncteur et laissez l unité refroidir avant d effectuer la moindre opération de maintenance ou de nettoyage NE PAS immerger l appareil ni le saturer d eau L appareil n est pas étanche à l eau Ne pas le faire fonctionner s il a été immergé ou saturé d ...

Страница 28: ...ts non abrasifs et des chiffons doux Les chiffons et nettoyant abrasifs pourraient érafler la finition de l unité entachant son apparence et la rendant susceptible à l accumulation de saleté Ne pas utiliser de produits chimiques puissants tels que de l eau de Javel ou des nettoyants contenant de l eau de Javel des nettoyants pour four pour nettoyer cet appareil Les dommages causés par des produits...

Страница 29: ... bacs dans chaque puits chauffant Un bac de grande taille Deux bacs de taille moyenne avec des barres d adaptation Trois bacs de petite taille avec des barres d adaptation Six bacs de très petite taille 1 6 avec des barres d adaptation Deux bacs ronds 6 6 litres avec un adaptateur Trois bacs ronds 3 8 litres avec un adaptateur Les bacs alimentaires barres de support de bacs et les ustensiles adapt...

Страница 30: ...its Ces modèles sont conçus pour être montés sur la face supérieure d une table de travail ininflammable ou sur un pont avec une table de travail inflammable en utilisant le kit d installation pour table de travail approprié NOTA La fonction d autoremplissage ne rempliera que le puits de gauche Pour remplir tous les puits les vidanges doivent être connectées à un collecteur d évacuation Modèles HW...

Страница 31: ...iquement Ajoutez 1 4 kg 3 lb pour les modèles D et DA Modèle HWBI43 1 pas disponible en 120 volts NOTA Le poids d embarquement comprend l emballage Tableau des valeurs nominales électriques suite NEMA 6 50P NEMA 6 30P NEMA 6 20P NEMA 6 15P NEMA 5 15P NEMA 5 20P NEMA 5 30P Configurations des fiches NOTA Prise non fournie par Hatco Configurations des fiches Certaines unités sont initialement fournie...

Страница 32: ...1 1 240 1 6015 17 4 3 208 1 6015 28 9 1 NEMA 6 50P 20 1 3 N A 240 1 6015 25 1 1 NEMA 6 50P 17 4 3 N A 220 230 1 2 2415 2640 3600 3935 11 0 11 5 16 4 17 1 1 1 N A 76 kg 167 lbs 230 240 1 2 2218 2415 3306 3600 9 6 10 1 14 4 15 0 1 1 HWBLI 6 120 1 4500 37 5 1 N A 86 kg 190 lbs HWBI 6 et HWBI43 6 208 1 2 3615 3600 17 4 17 3 1 1 208 1 7215 20 1 3 240 1 2 3615 3600 15 1 15 0 1 1 240 1 7215 17 4 3 208 1 ...

Страница 33: ...sions Vue de côté A B C 192 mm 7 9 16 76 mm 3 Orifice de vidange latéraux 178 mm 7 Vue de face 356 mm 14 Orifices de vidange inférieurs Bride de 8 mm 5 16 Les unités avec cadre grande dimension ont une profondeur B de 686 mm 27 Modéle Largeur A Profonduer B Hauteur C HWBI 1 394 mm 15 1 2 600 mm 23 5 8 244 mm 9 5 8 HWBI 2 749 mm 29 1 2 600 mm 23 5 8 244 mm 9 5 8 HWBI 3 1105 mm 43 1 2 600 mm 23 5 8 ...

Страница 34: ...érifiez auprès de leurs fabricants que le matériau peut supporter de façon durable des températures atteignant 93 C 200 F 1 Retirez l appareil du carton de livraison et retirez tous les éléments d emballage NOTA Pour éviter des retards dans l obtention de la couverture de la garantie complétez l enregistrement en ligne de votre garantie Lisez la section INFORMATIONS IMPORTANTES POUR LE PROPRIETAIR...

Страница 35: ...é avec un adhésif à base de silicone NOTA Un rouleau de joint mastic en bandes est fourni avec l unité Goujon de montage Goujon de montage Écrou de fixation Montage à goujon intégré 4 Placez l unité dans l ouverture de la table de travail et fixez la solidement aux goujons de montage avec des écrous de fixation de 6 3 mm 1 4 20 Serrez fermement les écrous 5 Coupez soigneusement et retirez l excès ...

Страница 36: ...n EZ 1073 mm 42 1 4 740 mm 29 1 8 N A N A HWBI 4 Clip de fixation EZ 1425 1432 mm 56 1 8 56 3 8 565 572 mm 22 1 4 22 1 2 N A N A Goujon 1425 1432 mm 56 1 8 56 5 16 721 mm 28 3 8 581 mm 22 7 8 Avec vis HWBI43 4 Clip de fixation EZ 1429 mm 56 1 4 740 mm 29 1 8 N A N A HWBI 5 Clip de fixation EZ 1781 1787 mm 70 1 8 70 3 8 565 572 mm 22 1 4 22 1 2 N A N A Goujon 1781 1786 mm 70 1 8 70 5 16 899 mm 35 3...

Страница 37: ...BI43 2 B A C D D D D HWBI 5 et HWBI43 5 B A C C D Modèles de découpe de table de travail NOTA L espace minimal nécessaire sous la découpe de la table de travail est de 333 mm 13 1 8 pour une installation sur des surfaces combustibles et 279 mm 11 pour les surfaces non combustibles Prévoyez un espace suffisamment large pour les unités équipées d un orifice de vidange ...

Страница 38: ...1 mm 4 3 4 438 mm 17 1 4 64 mm 2 1 2 INSTALLATION Installation du boîtier de commande à distance Installez le boîtier de commande sur la partie avant de l appareil pour vous assurer que les commandes correspondent bien aux puits concernés la partie avant de l appareil est le côté par lequel le conduit entre sous l appareil Les boîtiers de commande à distance ne peuvent pas être recâblés et doivent...

Страница 39: ...s concernant le collecteur d évacuation avec valve ATTENTION RISQUE DE BRÛLURES L eau de vidange peut atteindre des températures allant jusqu à 93 C 200 F Utilisez les matériaux de plomberie appropriés lors de l installation du système de vidange NOTA Consultez un entrepreneur en plomberie agréé pour que l installation du système de vidange soit conforme aux normes de plomberie locales NOTA En cas...

Страница 40: ...l option d auto remplissage assurez vous que le robinet de vidange est fermé 2 Placez un récipient vide dans le puits ou couvrir le puits avec un couvercle Cette étape est recommandée pour accélérer le préchauffage et d atteindre la température de fonctionnement 3 Placez l interrupteur I O marche arrêt sur I marche Le témoin lumineux de l interrupteur s allume lorsque l unité est en marche Si l un...

Страница 41: ...tes 1 Placez l interrupteur I O marche arrêt sur O arrêt et laissez l unité refroidir 2 Retirez et lavez tous les bacs et tous les adaptateurs 3 Ouvrez le robinet de vidange si présent ou évacuez manuellement l eau des puits si vous utilisez le fonctionnement à eau 4 Essuyez l intégralité de l unité à l aide d un chiffon ou d une éponge propre et d un détergent doux 5 Servez vous d une éponge à ré...

Страница 42: ... Vérifiez que l arrivée d eau est installée correctement Le robinet de remplissage de l eau ne fonctionnement pas correctement Contactez votre agent de maintenance agréé ou Hatco pour toute demande d assistance Le puits de gauche n est pas allumé Allumez le Les aliments ne sont pas conservés à une température suffisante Le puits fonctionne en mode à sec Laissez l unité refroidir et remplissez la a...

Страница 43: ...n acier inoxydable sont disponibles en différentes tailles ST PAN 1 3 Bac en acier inoxydable format 1 3 324L x 175P x 64H mm 12 3 4 x 6 7 8 x 2 1 2 ST PAN 1 2 Bac en acier inoxydable format 1 2 324L x 264P x 64H mm 12 3 4 x 10 3 8 x 2 1 2 ST PAN 2 Bac en acier inoxydable grande format de 64 mm 2 1 2 de profondeur 324L x 527P x 64H mm 12 3 4 x 20 3 4 x 2 1 2 ST PAN 4 Bac en acier inoxydable grande...

Страница 44: ...ivante pour convertir une unité monophasée en une unité triphasée AVERTISSEMENT DANGER DE DÉCHARGE ÉLECTRIQUE Placez l interrupteur sur Arrêt débranchez le cordon d alimentation arrêtez le courant au disjoncteur et laissez l unité refroidir avant d effectuer la moindre opération de maintenance ou de nettoyage Cette unité doit être entretenue uniquement par des personnes qualifiées Un entretien réa...

Страница 45: ...es fuites 4 Connectez le robinet de vidange au tuyau de vidange non fourni disponible sur place Robinet de vidange 19 mm 3 4 Raccord mâle au raccord de vidange Écrou de jonction Connexion du raccord extérieur aux robinets de vidange Cadre grande dimension Un cadre de grande dimension est disponible en option pour toutes les unités de la série HWDI Les modèles disposant d un cadre grande dimension ...

Страница 46: ...surremplissage ne sont pas couverts par la garantie Les joints d étanchéité doivent pouvoir supporter une température de 260 C 500 F minimum Les conduites d arrivée d eau doivent être conformes aux normes FDA relatives à l eau potable 1 Connectez le coude mâle et femelle à l emplacement de l auto remplissage situé à l extérieur du puits Replacez le tuyau de remplissage sur le raccord NOTA Il est p...

Страница 47: ...ans le raccord de vidange sur la partie inférieure ou latérale du puits 3 Vissez le raccord en T de laiton sur l embout de laiton 4 Vissez la bague de laiton à l intérieur du raccord en T de laiton 5 Connectez le coude de tuyau de remplissage à la bague de laiton NOTA Il est possible de vous deviez retirer le tuyau de remplissage du kit de plomberie pour faciliter l installation 6 Connectez le tuy...

Страница 48: ...pour pouvoir le réutiliser plus tard Le bouton n est plus nécessaire 3 A l aide de l écrou conservé à l étape précédente installez le raccord de robinet à la place de la poignée du robinet que vous avez retirée 4 Faites glisser la barre carrée à travers le raccord de poignée avec la goupille fendue en face 5 Insérez la goupille fendue dans la barre à l intérieur du raccord de poignée 6 Faites glis...

Страница 49: ...NTES AUX DROITS DE LA PROPRIÉTÉ INTELLECTUELLE Sans restreindre la portée générale des énoncés précédents CES GARANTIES NE COUVRENT PAS LES ÉLÉMENTS SUIVANTS ampoules d éclairage à incandescence enduites lumières fluorescentes ampoules de lampes chauffantes ampoules d éclairage à halogène enduites ampoules de lampes chauffantes au xénon tubes d éclairage DEL composants en verre et fusibles défaut ...

Страница 50: ...50 Formulaire n HWBIM 0319 Français NOTAS ...

Страница 51: ...Form No HWBIM 0319 51 English NOTES ...

Страница 52: ...973 575 9145 Service Plus Flanders 973 691 6300 NEW YORK Alpro Service Co Maspeth 718 386 2515 Duffy s AIS Buffalo 716 884 7425 3Wire Plattsburgh 800 634 5005 Duffy s AIS Sauquoit 800 836 1014 J B Brady Inc Syracuse 315 422 9271 NORTH CAROLINA Authorized Appliance Charlotte 704 377 4501 OHIO Akron Canton Comm Svc Inc Akron 330 753 6634 Tech 24 Cincinnati 513 772 6600 Commercial Parts and Service C...

Отзывы: