Control Enclosure Cutout Dimensions
Opening Dimensions
Screw Hole Dimensions
Model and Enclosure
(A)
(B)
(C)
(D)
HWBI-1 and HWBI43-1
Control w/Auto-Fill
10-1/8″ (257 mm)
4-3/4″ (121 mm)
10-7/16″ (265 mm)
2-1/2″ (64 mm)
Control w/o Auto-Fill
5-3/4″ (146 mm)
4-3/4″ (121 mm)
6-1/16″ (154 mm)
2-1/2″ (64 mm)
HWBI-2 and HWBI43-2
Control w/Auto-Fill
12-3/8″ (314 mm)
4-3/4″ (121 mm)
12-11/16″ (322 mm)
2-1/2″ (64 mm)
Control w/o Auto-Fill
8″ (203 mm)
4-3/4″ (121 mm)
8-5/16″ (211 mm)
2-1/2″ (64 mm)
HWBI-3 and HWBI43-3
Control w/ Auto-Fill
14-5/8″ (371 mm)
4-3/4″ (121 mm)
14-15/16″ (379 mm)
2-1/2″ (64 mm)
Control w/o Auto-Fill
10-1/4″ (260 mm)
4-3/4″ (121 mm)
10-9/16″ (268 mm)
2-1/2″ (64 mm)
HWBI-4 and HWBI43-4
Left Control w/ Auto-Fill
12-3/8″ (314 mm)
4-3/4″ (121 mm)
12-11/16″ (322 mm)
2-1/2″ (64 mm)
Left Control w/o Auto-Fill
8″ (203 mm)
4-3/4″ (121 mm)
8-5/16″ (211 mm)
2-1/2″ (64 mm)
Right Control
8″ (203 mm)
4-3/4″ (121 mm)
8-5/16″ (211 mm)
2-1/2″ (64 mm)
Control Enclosure w/ Auto-Fill
*
16-7/8″ (429 mm)
4-3/4″ (121 mm)
17-3/16″ (437 mm)
2-1/2″ (64 mm)
Control Enclosure w/o Auto-Fill
*
12-1/2″ (318 mm)
4-3/4″ (121 mm)
12-13/16 (325 mm)
2-1/2″ (64 mm)
HWBI-5 and HWBI43-5
Left Control w/ Auto-Fill
12-3/8″ (314 mm)
4-3/4″ (121 mm)
12-11/16″ (322 mm)
2-1/2″ (64 mm)
Left Control w/o Auto-Fill
8″ (203 mm)
4-3/4″ (121 mm)
8-5/16″ (211 mm)
2-1/2″ (64 mm)
Right Control
10-1/4″ (260 mm)
4-3/4″ (121 mm)
10-9/16″ (268 mm)
2-1/2″ (64 mm)
Control Enclosure w/ Auto-Fill
*
19-1/8″ (486 mm)
4-3/4″ (121 mm)
19-7/16″ (494 mm)
2-1/2″ (64 mm)
Control Enclosure w/o Auto-Fill
*
14-3/4″ (375 mm)
4-3/4″ (121 mm)
15-1/16″ (383 mm)
2-1/2″ (64 mm)
HWBI-6 and HWBI43-6
Left Control w/ Auto-Fill
14-5/8″ (371 mm)
4-3/4″ (121 mm)
14-7/8″ (378 mm)
2-1/2″ (64 mm)
Left Control w/o Auto-Fill
10-1/4″ (260 mm)
4-3/4″ (121 mm)
10-1/2″ (267 mm)
2-1/2″ (64 mm)
Right Control
10-1/4″ (260 mm)
4-3/4″ (121 mm)
10-1/2″ (267 mm)
2-1/2″ (64 mm)
Control Enclosure w/ Auto-Fill
*
21-3/8″ (543 mm)
4-3/4″ (121 mm)
21-5/8″ (549 mm)
2-1/2″ (64 mm)
Control Enclosure w/o Auto-Fill
*
17″ (432 mm)
4-3/4″ (121 mm)
17-1/4″ (438 mm)
2-1/2″ (64 mm)
INSTALLATION
Installing a Remote Control Enclosure
Remote control enclosures must be mounted on the front of
the unit to ensure the controls correspond with the correct wells
(the front of the unit is the side the conduit enters under the
unit). Remote control enclosures cannot be rewired and must
be installed in the proper location.
WARNING
ELECTRIC SHOCK HAZARD:
• Remote control enclosure must be mounted on vertical
wall and installed in vertical position. Mounting remote
control enclosure in horizontal position may result in
collection of liquids and lead to electric shock.
• Operating voltage of remote control enclosure water
valve exceeds 50 V (extra low voltage). Enclosure is
marked with the following hazard identification
symbol:
NOTE: A qualified electrician should connect the unit(s) to a
power source. A qualified plumber should connect the
water supply and drain(s).
NOTE: Refer to the “Side Mounted Auto-Fill” or “Bottom
Mounted Auto-Fill” procedure in the
OPTIONS AND
ACCESSORIES
section before installing a Remote
Control Enclosure.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the “Control Enclosure Cutout Dimensions” chart
below for the cutout dimensions for each control enclosure.
• The cutout depth required for all control enclosures is
5″ (127 mm).
• Make sure to have enough space inside the cutout if
installing with conduit on the side of the control enclosure.
• For units with two control enclosures: If the unit is
equipped with Auto-Fill, each enclosure cutout size will
be different (see chart below).
Control Enclosure Cutout Dimensions
*
HWBI-4, HWBI-5, and HWBI-6 units with all controls in a single control enclosure — required for Canadian units.
A
C
D
B
Front View –
Control Enclosure
Side View –
Control Enclosure
2-11/16″
(68 mm)
1-7/8″
(48 mm)
1-1/8″
(29 mm)
IMPORTANT NOTE:
Make sure the installation
location provides enough
room for electrical and
plumbing connections
to the control enclosure.
Follow local and national
plumbing and electrical
codes.