INSTALLATION
Remote Mounted Control Panel
WARNING
For proper and safe operation the remote
control panel location must be mounted on a
vertical wall.
CAUTION
To assure proper operation the remote mounted
control panel must be installed in the vertical
position.
NOTE: A qualified electrician is recommended for
connecting the Heated Well units to a power source.
A qualified plumber is recommended for connecting
drain(s).
1. Remove trim cover from control panel assembly.
2. Position control panel into opening through the
backside.
3. Secure control panel to surface using screws
(#8 sheet metal screw supplied).
4. Connect proper power source to the mounted
remote control panel .
5. Reinstall trim cover.
NOTE: Standard UL Approved units are equipped
with a 72" (1829 mm) flexible conduit connected to
the control panel.
Figure 14. Control Panel Opening Dimensions
B
CONTROL PANEL CUTOUT DIMENSIONS
Opening Dimensions
Screw Hole Dimensions
Model
(A)
(B)
(C)
(D)
Control Assembly
2-3/16"
3-3/8"
2-1/2"
3-1/4"
Without Bezel (Standard)
(55 mm)
(86 mm)
(64 mm)
(83 mm)
Control Assembly
3-1/4"
3-3/4"
4-1/8"
---
With Bezel (Standard)
(83 mm)
(92 mm)
(105 mm)
---
Control Assembly
5-7/8"
6-3/8"
3-7/8"
6-13/16"
Large (Optional)
(149 mm)
(162 mm)
(98 mm)
(173 mm)
B
B
A
A
A
C
C
C
D
D
Control Assembly Without
Bezel (Standard)
Control Assembly With
Bezel (Standard)
Control Assembly
Large (Optional)