Form No. RHWM_CN-0618
7
English
INSTALLATION
General
HEAT
MAX
Heated Well units are shipped from the factory with
most components assembled and ready for use. Care should
be taken when unpacking shipping carton to avoid damage to
unit and the components enclosed.
Built-in rectangular models require installation of the drain
assembly and remote mounted control panel.
WARNING
ELECTRIC SHOCK HAZARD: Unit is not weatherproof.
Locate unit indoors where ambient air temperature is a
minimum of 21°C (70°F).
FIRE HAZARD: Locate unit a minimum of 25 mm (1″) from
combustible walls and materials. If safe distances are not
maintained, discoloration or combustion could occur.
CAUTION
Locate unit at the proper counter height in an area that is
convenient for use. The location should be level to prevent
the unit or its contents from falling accidentally and strong
enough to support the weight of the unit and contents.
Do not move or relocate unit when it contains food
product. Turn off unit, remove food product, and allow to
cool completely before moving or cleaning.
NOTICE
Do not lay unit on the side with the control panel. Damage
to the unit could occur.
Do not locate unit in an area subject to excessive
temperatures or grease from grills, fryers, etc. Excessive
temperatures could cause damage to the unit.
1. Remove the unit from the carton.
NOTE: To prevent delay in obtaining warranty coverage,
complete online warranty registration. See the
IMPORTANT OWNER INFORMATION
section for
details.
2. Remove tape and protective packaging from all surfaces
of the unit and any accessories.
3. If the unit is a countertop model, place the unit in the
desired location.
• Locate the unit in an area where the ambient air
temperature is constant and a minimum of 21°C
(70°F). Avoid areas that may be subject to active air
movements or currents (i.e., near exhaust fans/hoods,
air conditioning ducts, exterior doors).
• Make sure the unit is at the proper counter height in an
area convenient for use.
• Make sure the countertop is level and strong enough to
support the weight of the unit and food product.
• Make sure all the feet on the bottom of the unit are
positioned securely on the countertop.
4. If the unit is a built-in model, perform the “Installing a
Built-In Model” procedure in this section.
Installing a Built-In Model
Use the following procedure(s) to install a built-in model into a
countertop. If the unit is a rectangular built-in model, perform
the “Installing the Drain Assembly” first.
NOTICE
Unit is designed and recommended for use in or on
metallic countertops. Damage to any countertop material
is not covered under the Hatco warranty. For other
surfaces, verify with manufacturer that material is suitable
for prolonged temperatures up to 100°C (212°F).
Installing the Drain Assembly
Before installing a rectangular model into the countertop,
perform the following procedure to install the drain assembly.
1. Carefully turn over the unit and lay it on its top side.
2. Remove the bottom panel screws and bottom panel.
3. Connect one end of the drain hose to the drain fitting using
the supplied hose clamp .
4. Route the drain hose through the hole in the bottom panel
and reinstall the bottom panel using the original screws.
5. Connect the other end of drain hose to a drain valve using
the supplied hose clamp.
6. Perform the “Installing the Unit into a Countertop”
procedure in this section. After installing the unit, the drain
valve may connect to external drain pipe, if desired.
Drain Hose
Hose Clamp
Hose Clamp
Drain Fitting
Bottom
Panel
Bottom
Panel
Screw
Drain Valve
Installing the Drain Assembly
(Built-in rectangular models only)