Form No. HDWM-0214
16
OPTIONS AND ACCESSORIES
English
Digital Temperature Controller
The digital temperature controller is factory installed and takes
the place of the standard drawer warmer control panel. use the
following procedure to operate the digital temperature controller.
Startup
1. Move the POWER ON/OFF (I/O) switch(es) to the ON
position.
• The corresponding digital temperature controller will
energize and the current temperature of the drawer or
“LO” will appear on the TEMPERaTuRE display. “LO”
indicates the drawer temperature is below
70°F (21°C).
2. Press the
key on the digital temperature controller two
times to verify the setpoint temperature. (“SP will be
displayed after the first press.) See the RECOMMENDED
SETTINGS chart on the control panel or the FOOD
HOLDING GuIDE in this manual.
• The setpoint temperature will be shown for 10 seconds.
after 10 seconds, the TEMPERaTuRE display will
revert to the current temperature of the unit. To change
the setpoint temperature, refer to “Changing the
Setpoint Temperature” in this section.
NOTE: The digital temperature controller is pre-set to a setpoint
temperature of 185°F (85°C) at the factory. Once the
setpoint temperature is changed, the new setpoint
temperature will remain in memory until it is changed
again. The minimum to maximum setpoint temperature
range is 70°F (21°C) to 200°F (93°C).
BURN HAzARD:
• Some exterior surfaces on unit will get hot. Use caution
when touching these areas.
• Use caution when opening drawer. Hot air escapes
when drawer is open.
3. allow unit 15–20 minutes to reach operating temperature.
Shutdown
1. Move the Power ON/OFF (I/O) switch to the OFF (O)
position. The digital temperature controller and heated
drawer will shut off.
Changing the Setpoint Temperature
use the following procedure to change the setpoint
temperature.
1. Press the
key two times. The current setpoint
temperature will be shown on the TEMPERaTuRE display
(“SP” will be displayed after the first press).
2. Press the
key or
key within 15 seconds to change
the setpoint temperature. Pressing and holding the
key
or
key will scroll through the setpoints faster. If no key
is pressed within 15 seconds, the TEMPERaTuRE display
will revert to the current temperature of the drawer.
3. Press the
key or wait 15 seconds to lock in the new
setpoint temperature. The TEMPERaTuRE display will go
blank for two seconds to show that the new setting has
been accepted.
CAUTION
Control Panel with Digital Temperature Controler
Digital
Temperature
Controller
RECOMMENDED
SETTINGS Chart
POWER ON/OFF
Switch