General
Use the following procedure to turn on and operate Hatco
Built-In Heated Glass Shelves.
WARNING
Read all safety messages in the IMPORTANT SAFETY
INFORMATION section before operating this equipment.
NOTICE
Do not turn on unit until it has been cleaned thoroughly.
Ceramic glass surface must be clear of debris to prevent
burn-on.
Use only wipes, pads, and cleaners designed specifically
for cleaning ceramic glass surfaces. Using other wipes,
pads, or cleaners may damage ceramic glass surface.
Do not slide pans across glass surface, use rough-
bottomed pans, or drop anything on glass surface.
Scratching or breakage may occur. Damage to glass
surface or breakage of glass caused by misuse is not
covered under warranty.
1. Using an appropriate cleaning wipe or a damp cloth, clean
and sanitize the glass surface of the unit. Consistent daily
cleaning will keep cleanup easy as well as protect and
preserve the glass surface of the unit.
2. Plug unit into a properly grounded electrical receptacle of
the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
3. Move the Power I/O (on/off) switch to the
I
(on) position.
• The unit will heat up to the setpoint temperature
automatically.
• Refer to the “Changing the Setpoint Temperature”
procedure to adjust the setpoint temperature.
CAUTION
BURN HAZARD: Some exterior surfaces on the unit will
get hot. Use caution when touching these areas.
4. Allow the unit 30 minutes to reach operating temperature.
Changing the Setpoint Temperature
Use the following procedure to adjust the setpoint temperature.
NOTICE
Built-in units must not have a setpoint temperature higher
than 125°C (257°F). Temperatures exceeding 125°C (257°F)
will damage unit and void warranty.
NOTE: The temperature shown on the display may be inaccurate
when unit temperature is below 54°C (130°F).
1. Press the
key. The current setpoint temperature will be
shown on the temperature display.
2. Press the
key or
key within 8 seconds to change
the setpoint temperature.
OPERATION
Control Box Installation Dimensions
Up Arrow Key
Down Arrow Key
Power I/O (on/off) Switch
Temperature Key
Содержание HBGBHC Series
Страница 13: ...HBGBHCM_CN 0120 13 21 C 70 F Hatco Hatco Hatco Hatco 25 1 0512 6732 5091 29 C 85 F...
Страница 16: ...16 HBGBHCM_CN 0120 HBGBHC 21 C 70 F 25 1 1 2 3 4 a b 5 6 NSF 121 C 250 F 7 a b 8 9 29 C 85 F 1 2 3 1829 6...
Страница 18: ...18 HBGBHCM_CN 0120 Hatco 1 2 3 4 30 125 C 257 F 125 C 257 F 54 C 130 F 1 2 8 I O 0...
Страница 19: ...HBGBHCM_CN 0120 19 0512 6732 5091 1 2 a b 1 2 3 4 5 1 2 3 4 5 1 2 3 4...
Страница 22: ...22 Form No HBGBHCM_CN 0120...
Страница 23: ...Form No HBGBHCM_CN 0120 23...